Samsung AQV09PSAX, AQV12PWAX, AQV12PSBX manual Sub PCB installationoptional, Take off the Cover PCB

Page 42
Sub PCB installation(optional)

 

 

 

Sub PCB installation(optional)

 

 

 

 

 

 

AA

Only for multi system

 

(Wried remote controller, central remote controller etc.)

 

 

1. Turn the power off and take off the front panel of the indoor unit.

2.Take off the Cover PCB.

3.Attach the Sub PCB to the right side of the Panel-frame.

4.Find the PCB wire, and connect the wire to the Sub PCB as seen in the picture.

5.Connect the wire(remote controller, central remote controller etc) to the Sub PCB.

CoverPCB

Sub PCB

6. Assemble the Cover PCB and the front panel.

• The Sub PCB is attached to be controlled by the wired remote controller and central controller.

42

Image 42 Contents
Page Cost Efficient System Features of your new air conditionerCool Summer Offer Look for EverywhereImportant safety symbols and precautions Safety precautionsUSING PARTS FOR INSTALLATIONDo not pull the power cord, when unplugging the power plug FOR USINGFOR POWER SUPPLY Do not touch the power plug or the circuit breaker with wet handsDo not place objects or devices under the indoor unit FOR CLEANINGDo not clean the inside of the air conditioner by yourself Do not operate the appliance with wet handsModel RJ Checking before useOperation ranges Maintaining your air conditionerMain parts Power buttonChecking the name of the parts DisplayRemote controller display Smart Saver Checking the remote controllerRemote controller buttons On TimerStoring the remote controller Remote controller displayBattery changing time Turbo indicatorCool Basic functionAuto HeatPress the button to set the operating mode button to adjust the temperaturePress the button to turn on the air conditioner Press thePress the Air swingbutton on the remote controller Adjusting the air flow directionUsing the Turbo function Press the Turbo button on the remote controller during Cool modemode When the air conditioner is on and in cool/heat mode1. Press the button on the remote controller Temperature and fan speed changes in mode1. Press the On Timer/Off Timer button Setting the On/Off timerSetting On timer Setting Off timer Additional options available in On timer modeIf the air conditioner is off Using the Smart Saver functionIf the air conditioner is on Combining On Timer and Off TimerPress the Auto Clean button When the air conditioner is turned off Using the Quiet functionUsing the Auto Clean function When the air conditioner is turned onCleaning the outdoor unit heat exchanger Cleaning the air conditionerCleaning the indoor unit Opening the panelOpen the panel and put the Air filter out Cleaning the air filterRemoving the Air filter Dry the Air filter in a ventilated areaMaintaining the air conditioner Periodical checksSOLUTION TroubleshootingPROBLEM not work at allflow movement changes. It is normal Error is indicatedNoise is generated the outdoor unitINSTALLATION PARTS General informationIncluded Models Power supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit Indoor unitOutdoor Unit Space Requirements for Outdoor Unit When installing 1 outdoor unitWhen installing more than 1 outdoor unit Top viewAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case Tools required for installation General Tools Fixing the installation plateOptional accessories Tools for test operationsConnecting the cable Connecting the assembly cableCable specification Power cableof the electrical contact during a wiring work 11. Close the terminal board cover by tightening the screw carefully Installing and connecting the assembly pipe of the indoor unit10. Connect the grounding conductor to the grounding terminals 2. Smooth the cut edges4. Cut off the remaining foam insulation Purging the indoor unitCutting or extending the pipe 6. Pass the pipe through the hole in the wallOuter Diameter 4. Put a flare nut slightly into the pipe and modify the flareDepth A Outer Diameter DInstalling and connecting the drain hose of the indoor unit Drain hose installation1. Detach the rubber cap with the plier Installing and connecting the drain hose of the indoor unitChanging direction of the drain hose 2. Detach the drain hose by pulling it and turning to the left2. Connect a drain hose to the drain plug InstallAA ing and connecting the drain hose of the outdoor unitPurging the connected pipes 3. Ensure that condensation draining is adequateIf you use a pipe longer than 5m gas service port as seen in the pictureAdding Refrigerant If you use a pipe shorter than 5m1. Please fill in with indelible ink Important information regulation regarding the refrigerant usedCylinder with siphon 1975To check for gas leaks on the indoor unit PerfoAA rming the gas leak testsTo check for gas leaks on the outdoor unit Leak test with nitrogen before opening valvesFixinAA g the indoor unit in place Outdoor unit installed on the wall by rack6. Attach the pipe to the wall using clamps optional Fixing the outdoor unit in placeFinalAA Check and Trial Operation 1. Press the Power button and check the following4. Press the Power button to stop the operation Check the followings5. Apply heat to the contraction tube to contract it The compression dimension should beand compress another two points in the same location 6. After tube contraction work is completed, wrap it with the2. Take off the Cover PCB Sub PCB installationoptional1. Turn the power off and take off the front panel of the indoor unit 3. Attach the Sub PCB to the right side of the Panel-frameENGLISH CALL QUESTIONS OR COMMENTS?COUNTRY EEE Yönetmeliğine Uygundur This EEE is compliant with RoHSimagine the possibilities user & installation manualAir Conditioner AQV07P Series AQV09P Series AQV12P Series AQV18P Series
Related manuals
Manual 41 pages 25.73 Kb Manual 41 pages 25.56 Kb Manual 41 pages 6.72 Kb Manual 45 pages 23.92 Kb Manual 41 pages 27.43 Kb Manual 43 pages 36.93 Kb Manual 43 pages 57.93 Kb Manual 41 pages 20.41 Kb Manual 21 pages 39.04 Kb Manual 21 pages 44.89 Kb Manual 21 pages 49.66 Kb Manual 21 pages 36.79 Kb Manual 21 pages 55.58 Kb Manual 45 pages 44.27 Kb Manual 45 pages 56.11 Kb Manual 43 pages 7.81 Kb Manual 43 pages 10.58 Kb Manual 45 pages 17.94 Kb Manual 43 pages 52.7 Kb