Samsung AR18HVSDEWKNMG Setting the Beep sound, Resetting the Filter clean reminder, English-27

Page 27

Setting the Beep sound

Beep sound from the indoor unit can be muted.

1. Press the Settings button..

2. Press the ,or Setting button until (Beep) indicator starts to blink..

3. Press the SET button to mute the beep sound..

-- 3 seconds after setting Beep sound function, (Beep) indicator on the remote controller display will disappear and Beep sound function will begin.

s ng05 setti

Resetting the Filter clean reminder

When Filter clean reminder ( ) lights up on the indoor unit display, clean the filter and reset the reminder byfollowing this instruction.

1. Press the Settings button..

2. Press the ,or Setting button until (Filter Reset) indicator starts to blink.. 3. Press the SET button to reset Filter clean reminder..

-- 3 seconds after setting Filter clean reminder function, (Filter Reset) indicator on the remote controller display will disappear and () indicator on the indoor unit display will disappear..

Indoor unit display

Setting the Display option

Display lighting can be adjusted by following this instruction.

1. Press the Settings button..

2. Press the ,or Setting button until (Display) indicator starts to blink..

3. Press the SET button to set the display status..

-- 3 seconds after setting Display function, (Display) indicator on the remote controller display will disappear and indoor unit display will be turned off..

ffPress the Setting button Press the ,or Setting button to

Cancel

make the (Display) indicator blink and press the SET button..

-- (Display) indicator on the remote controller display will disappear

 

 

and the indoor unit display will be turned on again..

Display option cannot be set when the air conditioner is off.

• If you turn off the display when the Virus doctor function is in operation with air conditioner operation, the indoor unit display and Virus Doctor lamp will be turned off at the same time.

Operation or timer display will not be turned off by the display off function.

English-27

MG_BETTER_INV_A3050_IB&IM_EN_DB68-05191A_UX.indd 27

2/17/2015 2:48:09 PM

Image 27
Contents DB68-05191A-02 Air ConditionerFeatures of your new air conditioner Contents English-4 Safety precautions01epPr aration English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningChecking before use Operation rangesEnglish-10 English-11 Technical SpecificationsDisplay Wi-Fi indicator Timer / Auto Clean indicatorChecking the name of the parts Main partsChecking the remote controller Remote controller buttonsEnglish-13 Inserting the batteries Remote controller displayLow Battery warning Storing the remote controllerBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-16 Vertical air flow Horizontal air flow Adjusting the air flow directionRemote controller displayRemote controller display English-17FfPress the Timer button select On press the or button  Setting the On/Off timerSetting the On timer When the air conditioner is offButton Setting the Off timerEnglish-19 Er03mtiAdditional options available in mode ModeEnglish-20 Press the Options button When the air conditioner is operating in Cool modeStep cooling function English-21English-22 Using the Fast functionUsing the Comfort function When the air conditioner is operating in Cool/Heat modeEnglish-23 Using the Single user functionUsing the Quiet function Make the Quiet indicator blink and press the SET buttonEnglish-24 Make the indicator blink and press the SET button Using the Virus Doctor functionWhen the air conditioner is operating When the air conditioner is not in operationMake the Clean indicator blink and press the SET button Checking the power consumptionUsing the Auto clean function Lighting in Auto clean modeEnglish-27 Setting the Beep soundResetting the Filter clean reminder Setting the Display optionEnglish-28 Using the Smart A/C applicationEnglish-29 Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerRemove the Air filter from the main body Cleaning the Air filterRemoving the Air filter English-30Reassembling the Air filter English-31Top of the Air filter into the main body.. ➀ English-32 Maintaining the air conditionerEnglish-33 TroubleshootingTemperature Adjustment is notHeard when refrigerant flow movement changes. It is normal Button or disconnect the power plug/switchCheck the Drains have been cleared Regular Maintenance Error is indicatedGeneral information English-3507stin llan atio Indoor unit Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerReduce noise and vibration Where sulfide gas existsOutdoor Unit English-37 Figure Description When installing more than 1 outdoor unitWhen the air outlet is towards the wall English-38English-39 AccessoriesAccessories in the indoor unit case Accessories in the outdoor unit caseTools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsEnglish-41 Assembling the hanger screwEnglish-42 This QR code for detail video of indoor unit installationRemoving the screws Removing the Cover panel Before mounting the indoor unitEnglish-43 Assembling the Cover panel After mounting the indoor unitEnglish-44 Connecting the assembly cableCable specification Connecting the cableExtend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-45 Torque English-46Smooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe Evacuating the indoor unitCutting or extending the pipe English-47Flare nut English-48Correct Inclined CrackedEnglish-49 Drain hose installationCheck for leakage on both side of the drain outlet Change the direction only when it is necessaryChanging direction of the drain hose English-50Outdoor unit Indoor unit Evacuating the connected pipesEnglish-51 Outer TorqueIf you use a pipe longer than 5 m Adding RefrigerantEnglish-52 Cylinder with siphonEnglish-53 Performing the gas leak tests660 340 Outdoor unit installed on the wall by rackFixing the outdoor unit in place English-54English-55 Smart Install modeOff / Blinking / On English-56English-57 Final check and trial operationEnglish-58 Packing and unpacking guideAtio After tube contraction work is completed, wrap it with How to connect your extended power cablesEnglish-59 Apply heat to the contraction tube to contract it021-8255 CE Questions or COMMENTS?