Samsung AR24HVSDEWKNMG, AR24HVSDEWKXMG manual Changing direction of the drain hose, English-50

Page 50

Installing and connecting the drain hose of the indoor unit

6.

Pass the drain hose under the refrigerant pipe, keeping the drain hose tight.

Shield

7.

Pass the drain hose through the hole in the wall. Check if it slants

 

downwards as seen in the picture.

 

 

 

8. Using natural drainage method, check the drainage is normal.

Drain hose

Extension drain hose

• The hose will be fixed permanently into position after finishing the installation and the gas leak test;

refer to page 54 for further details.

• Make sure the installed direction of the drain hose is correct. Inadequate installation may cause condensate water leakage.

• If the drain hose is routed inside the room, insulate the hose so that dripping condensation does not damage the furniture or floors.

DO NOT WALL UP THE DRAIN HOSE CONNECTION !

Drain hose connection must be easy accessible and serviceable.

Changing direction of the drain hose

Change the direction only when it is necessary.

1.Detach the rubber cap with the pliers.

2.Detach the drain hose by pulling it and turning to the right.

3. Insert the drain hose by fixing it with the screw into the groove of the drain hose and the outlet of the drain pan.

Screw hole

Screw

Drain hose

4. Attach the rubber cap with a screwdriver by turning it to the left until it fixes to the end of the groove.

Drain pan outlet

Rubber cap

5. Check for leakage on both side of the drain outlet.

Pour the water in direction of arrow.

Direction of the drained water

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Make sure the indoor unit is in upright position when you pour water to check for leakage. Make sure that the water does not overflow onto the electrical part.

English-50

MG_BETTER_INV_A3050_IB&IM_EN_DB68-05191A_UX.indd 50

2/17/2015 2:50:23 PM

Image 50
Contents Air Conditioner DB68-05191A-02Features of your new air conditioner Contents Safety precautions English-4English-5 01epPr arationFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9English-10 Checking before useOperation ranges Technical Specifications English-11Main parts Wi-Fi indicator Timer / Auto Clean indicatorChecking the name of the parts DisplayEnglish-13 Checking the remote controllerRemote controller buttons Storing the remote controller Remote controller displayLow Battery warning Inserting the batteriesBasic function English-16 Press the button to adjust the temperaturePress the button to set the desired fan speed English-17 Adjusting the air flow directionRemote controller displayRemote controller display Vertical air flow Horizontal air flowWhen the air conditioner is off Setting the On/Off timerSetting the On timer FfPress the Timer button select On press the or button Er03mti Setting the Off timerEnglish-19 ButtonEnglish-20 Additional options available in modeMode English-21 When the air conditioner is operating in Cool modeStep cooling function Press the Options buttonWhen the air conditioner is operating in Cool/Heat mode Using the Fast functionUsing the Comfort function English-22Using the Single user function English-23English-24 Using the Quiet functionMake the Quiet indicator blink and press the SET button When the air conditioner is not in operation Using the Virus Doctor functionWhen the air conditioner is operating Make the indicator blink and press the SET buttonLighting in Auto clean mode Checking the power consumptionUsing the Auto clean function Make the Clean indicator blink and press the SET buttonSetting the Display option Setting the Beep soundResetting the Filter clean reminder English-27Using the Smart A/C application English-28Cleaning the outdoor unit heat exchanger Cleaning the air conditionerCleaning the indoor unit English-29English-30 Cleaning the Air filterRemoving the Air filter Remove the Air filter from the main bodyTop of the Air filter into the main body.. ➀ Reassembling the Air filterEnglish-31 Maintaining the air conditioner English-32Adjustment is not TroubleshootingTemperature English-33Error is indicated Button or disconnect the power plug/switchCheck the Drains have been cleared Regular Maintenance Heard when refrigerant flow movement changes. It is normal07stin llan atio General informationEnglish-35 Power supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit Indoor unitEnglish-37 Where sulfide gas existsOutdoor Unit Reduce noise and vibrationEnglish-38 When installing more than 1 outdoor unitWhen the air outlet is towards the wall  Figure DescriptionAccessories in the outdoor unit case AccessoriesAccessories in the indoor unit case English-39Tools required for installation General Tools Fixing the installation plateOptional accessories Tools for test operationsAssembling the hanger screw English-41Removing the Cover panel Before mounting the indoor unit This QR code for detail video of indoor unit installationRemoving the screws English-42Assembling the Cover panel After mounting the indoor unit English-43Connecting the cable Connecting the assembly cableCable specification English-44English-45 Extend the assembly cable if necessaryEach wire is labeled with the corresponding terminal number Cut off the remaining foam insulation English-46Smooth the cut edges TorqueEnglish-47 Evacuating the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeCracked English-48Correct Inclined Flare nutDrain hose installation English-49English-50 Change the direction only when it is necessaryChanging direction of the drain hose Check for leakage on both side of the drain outletOuter Torque Evacuating the connected pipesEnglish-51 Outdoor unit Indoor unitCylinder with siphon Adding RefrigerantEnglish-52 If you use a pipe longer than 5 mPerforming the gas leak tests English-53English-54 Outdoor unit installed on the wall by rackFixing the outdoor unit in place 660 340Smart Install mode English-55English-56 Off / Blinking / OnFinal check and trial operation English-57Packing and unpacking guide English-58Apply heat to the contraction tube to contract it How to connect your extended power cablesEnglish-59 Atio After tube contraction work is completed, wrap it withQuestions or COMMENTS? 021-8255 CE