Evacuating the connected pipes
Adding Refrigerant
Add refrigerant charge according to table below:
If you use a pipe longer than 5 m,
‘A’g of refrigerant
If you use a pipe shorter than 5 m,
The evacuating time is normal.
Refer to the Service Manual for further details.
Model | A |
|
|
18/24 | 15 |
|
|
• The remaining air in the Refrigeration cycle, which contains moisture, may cause malfunction on the compressor.
• Always contact the service center or a professional installation agency for product installation.
Charging the refrigerant under conditions of liquid by using a liquid pipe
1.Before recharging, check whether the cylinder has a siphon or not. There are two ways to recharge the refrigerant.
Cylinder with siphon | Cylinder without siphon |
Siphon
Charge the refrigerant standing the cylinder upright.
Charge the refrigerant turning the cylinder upside down.
• If
characteristics of the equipment vary.
•During the measuring operation of refrigerant quantity added use electronic scales.
If cylinder doesn’t have syphon, upset it.
English-52