Samsung AR18HVSDEWKXMG, AR24HVSDEWKXMG, AR24HVSDEWKNMG Final check and trial operation, English-57

Page 57

Final check and trial operation

To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly.

Check the followings:

Strength of the installation site

Tightness of pipe connection to detect gas leak

Electric wiring connection

Heat-resistant insulation of the pipe

Drainage

Grounding conductor connection

Correct operation (follow the steps below)

1. Press the Power button and check the following:

The indicator on the indoor unit lights up.

The airflow blade opens and the fan gears up for operation.

2. Press the Mode button to select Cool or Heat mode.

In Cool mode, use Temp hr. + or button and set the temperature at 16 °C. In Heat mode, use Temp hr. + or button and set the temperature at 30 °C.

• Approximately 3~5 minutes later, outdoor unit will start to operate and the

Cool or Warm air will blow out.

• After 12 minutes of stationary condition check the indoor unit air treatment.

Cooling mode (indoor unit check) Inlet air temp. - Outlet air temp: From 10 °C to 12 °C (indicative delta T)

Heating mode (indoor unit check) Outlet air temp. - Inlet air temp: From 11 °C to 14 °C (indicative delta T)

In heating mode, the indoor fan motor can remain off to avoid cold air blown into conditioned space.

3.Press the Air swing button and check the following:

The airflow blades work properly.

4.Press the Power button to stop the operation.

• When you complete the installation successfully, hand over this manual to the user for storage in a handy and safe

place.

Pump down procedure (when removing the product)

1.Press the Power button on the indoor unit for 5 seconds. Beep will sound immediately to let you know that the product is ready for pump down procedure. Please let the compressor run for more than 5 minutes.

2 . Release the valve caps on High and Low pressure side.

3 . Use L wrench to close the valve on the high pressure side.

4 . After approximately 2 minutes, close the valve on the low pressure side.

5 . Stop operation of the air conditioner by pressing the Power button on the indoor unit or remote controller.

6 . Disconnect the pipes.

English-57

07stin llan atio

MG_BETTER_INV_A3050_IB&IM_EN_DB68-05191A_UX.indd 57

2/17/2015 2:50:54 PM

Image 57
Contents DB68-05191A-02 Air ConditionerFeatures of your new air conditioner Contents English-4 Safety precautions01epPr aration English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningChecking before use Operation rangesEnglish-10 English-11 Technical SpecificationsChecking the name of the parts Wi-Fi indicator Timer / Auto Clean indicatorMain parts DisplayChecking the remote controller Remote controller buttonsEnglish-13 Low Battery warning Remote controller displayStoring the remote controller Inserting the batteriesBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-16 Remote controller displayRemote controller display Adjusting the air flow directionEnglish-17 Vertical air flow Horizontal air flowSetting the On timer Setting the On/Off timerWhen the air conditioner is off FfPress the Timer button select On press the or button English-19 Setting the Off timerEr03mti ButtonAdditional options available in mode ModeEnglish-20 Step cooling function When the air conditioner is operating in Cool modeEnglish-21 Press the Options buttonUsing the Comfort function Using the Fast functionWhen the air conditioner is operating in Cool/Heat mode English-22English-23 Using the Single user functionUsing the Quiet function Make the Quiet indicator blink and press the SET buttonEnglish-24 When the air conditioner is operating Using the Virus Doctor functionWhen the air conditioner is not in operation Make the indicator blink and press the SET buttonUsing the Auto clean function Checking the power consumptionLighting in Auto clean mode Make the Clean indicator blink and press the SET buttonResetting the Filter clean reminder Setting the Beep soundSetting the Display option English-27English-28 Using the Smart A/C applicationCleaning the indoor unit Cleaning the air conditionerCleaning the outdoor unit heat exchanger English-29Removing the Air filter Cleaning the Air filterEnglish-30 Remove the Air filter from the main bodyReassembling the Air filter English-31Top of the Air filter into the main body.. ➀ English-32 Maintaining the air conditionerTemperature TroubleshootingAdjustment is not English-33Check the Drains have been cleared Regular Maintenance Button or disconnect the power plug/switchError is indicated Heard when refrigerant flow movement changes. It is normalGeneral information English-3507stin llan atio Installing the unit Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitOutdoor Unit Where sulfide gas existsEnglish-37 Reduce noise and vibrationWhen the air outlet is towards the wall When installing more than 1 outdoor unitEnglish-38  Figure DescriptionAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case English-39Optional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsEnglish-41 Assembling the hanger screwRemoving the screws This QR code for detail video of indoor unit installationRemoving the Cover panel Before mounting the indoor unit English-42English-43 Assembling the Cover panel After mounting the indoor unitCable specification Connecting the assembly cableConnecting the cable English-44Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-45 Smooth the cut edges English-46Cut off the remaining foam insulation TorqueCutting or extending the pipe Evacuating the indoor unitEnglish-47 Unscrew the caps at the end of each pipeCorrect Inclined English-48Cracked Flare nutEnglish-49 Drain hose installationChanging direction of the drain hose Change the direction only when it is necessaryEnglish-50 Check for leakage on both side of the drain outletEnglish-51 Evacuating the connected pipesOuter Torque Outdoor unit Indoor unitEnglish-52 Adding RefrigerantCylinder with siphon If you use a pipe longer than 5 mEnglish-53 Performing the gas leak testsFixing the outdoor unit in place Outdoor unit installed on the wall by rackEnglish-54 660 340English-55 Smart Install modeOff / Blinking / On English-56English-57 Final check and trial operationEnglish-58 Packing and unpacking guideEnglish-59 How to connect your extended power cablesApply heat to the contraction tube to contract it Atio After tube contraction work is completed, wrap it with021-8255 CE Questions or COMMENTS?