Samsung AR18HVSDEWKXMG, AR24HVSDEWKXMG manual English-45, Extend the assembly cable if necessary

Page 45

Connecting the assembly cable

1. Extend the assembly cable if necessary.

• Do not connect two or more different cables to extend the length. It may cause fire.

2 . Open the cover panel.

3 . Remove the screw securing the connector cover.

4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals. (Refer to the picture below)

• Each wire is labeled with the corresponding terminal number.

5 . Pass the other end of the cable through the 65 mm hole in the wall.

6 . Close the connector cover by tightening the screw carefully.

7 . Close the cover panel.

8 . Remove the terminal board cover on the side of the outdoor unit. 9. Connect the cables to the terminals as seen in the picture.

07stin llan atio

Indoor unit

Indoor unit

Outdoor unit

Outdoor unit

1(L)

2(N)

F1

F2

1(L) 2(N) F1 F2

L

N

F1

F2

• Also circular terminal must be matched with screw size in terminal block.

• After connecting the cables, make sure terminal numbers on the indoor/outdoor unit matches.

Please ensure that Power & Communication cables are separated, they must not be in the same cable.

10.Connect the grounding conductor to the grounding terminals.

11.Close the terminal board cover by tightening the screw carefully.

Connect the wires firmly so that wires can not be pulled out easily.

(If they are loose, it could cause burn-out of the wires.)

Connect the wires according to color codes, referring to the wiring diagram.

The power cable and the interconnection cable should be selected according to the specification in page 44.

English-45

MG_BETTER_INV_A3050_IB&IM_EN_DB68-05191A_UX.indd 45

2/17/2015 2:49:56 PM

Image 45
Contents DB68-05191A-02 Air ConditionerFeatures of your new air conditioner Contents English-4 Safety precautions01epPr aration English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningChecking before use Operation rangesEnglish-10 English-11 Technical SpecificationsChecking the name of the parts Wi-Fi indicator Timer / Auto Clean indicatorMain parts DisplayChecking the remote controller Remote controller buttonsEnglish-13 Low Battery warning Remote controller displayStoring the remote controller Inserting the batteriesBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-16 Remote controller displayRemote controller display Adjusting the air flow directionEnglish-17 Vertical air flow Horizontal air flowSetting the On timer Setting the On/Off timerWhen the air conditioner is off FfPress the Timer button select On press the or button English-19 Setting the Off timerEr03mti ButtonAdditional options available in mode ModeEnglish-20 Step cooling function When the air conditioner is operating in Cool modeEnglish-21 Press the Options buttonUsing the Comfort function Using the Fast functionWhen the air conditioner is operating in Cool/Heat mode English-22English-23 Using the Single user functionUsing the Quiet function Make the Quiet indicator blink and press the SET buttonEnglish-24 When the air conditioner is operating Using the Virus Doctor functionWhen the air conditioner is not in operation Make the indicator blink and press the SET buttonUsing the Auto clean function Checking the power consumptionLighting in Auto clean mode Make the Clean indicator blink and press the SET buttonResetting the Filter clean reminder Setting the Beep soundSetting the Display option English-27English-28 Using the Smart A/C applicationCleaning the indoor unit Cleaning the air conditionerCleaning the outdoor unit heat exchanger English-29Removing the Air filter Cleaning the Air filterEnglish-30 Remove the Air filter from the main bodyReassembling the Air filter English-31Top of the Air filter into the main body.. ➀ English-32 Maintaining the air conditionerTemperature TroubleshootingAdjustment is not English-33Check the Drains have been cleared Regular Maintenance Button or disconnect the power plug/switchError is indicated Heard when refrigerant flow movement changes. It is normalGeneral information English-3507stin llan atio Installing the unit Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitOutdoor Unit Where sulfide gas existsEnglish-37 Reduce noise and vibrationWhen the air outlet is towards the wall When installing more than 1 outdoor unitEnglish-38  Figure DescriptionAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case English-39Optional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsEnglish-41 Assembling the hanger screwRemoving the screws This QR code for detail video of indoor unit installationRemoving the Cover panel Before mounting the indoor unit English-42English-43 Assembling the Cover panel After mounting the indoor unitCable specification Connecting the assembly cableConnecting the cable English-44Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-45 Smooth the cut edges English-46Cut off the remaining foam insulation TorqueCutting or extending the pipe Evacuating the indoor unitEnglish-47 Unscrew the caps at the end of each pipeCorrect Inclined English-48Cracked Flare nutEnglish-49 Drain hose installationChanging direction of the drain hose Change the direction only when it is necessaryEnglish-50 Check for leakage on both side of the drain outletEnglish-51 Evacuating the connected pipesOuter Torque Outdoor unit Indoor unitEnglish-52 Adding RefrigerantCylinder with siphon If you use a pipe longer than 5 mEnglish-53 Performing the gas leak testsFixing the outdoor unit in place Outdoor unit installed on the wall by rackEnglish-54 660 340English-55 Smart Install modeOff / Blinking / On English-56English-57 Final check and trial operationEnglish-58 Packing and unpacking guideEnglish-59 How to connect your extended power cablesApply heat to the contraction tube to contract it Atio After tube contraction work is completed, wrap it with021-8255 CE Questions or COMMENTS?
Related manuals
Manual 22 pages 11.55 Kb