Installing the unit

IMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Always disassemble the electric lines before the refrigerant tubes.

Upon receipt, inspect the product to verify that it has not been damaged during transport.

If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician has collected the material from the retailer.)

After completing the installation, always carry out a functional test and provide the instructions on how to operate the air conditioner to the user.

Do not use the air conditioner in environments with hazardous substances or close to equipment that release free flames to avoid the occurrence of fires, explosions or injuries.

To help prevent injury when accidentally touching the indoor unit fan, install the indoor unit at least 2.5 m above the floor.

The air conditioner should be used only for the applications for which it has been designed : the indoor unit is not suitable to be installed in areas used for laundry.

Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs. The units’components must be accessible and that can be disassembled in conditions of complete safety either for people or things.

For this reason, where it is not observed as indicated into the Installation Manual, the cost necessary to reach and repair the unit (in safety, as required by current regulations in force) with slings, trucks, scaffolding or any other means of elevation won’t be considered in-warranty and charged to end user.

Power supply line, fuse or circuit breaker

Always make sure that the power supply is compliant with current safety standards. Always install the air conditioner in compliance with current local safety standards.

Always verify that a suitable grounding connection is available.

Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines.

Always verify that the cut-off and protection switches are suitably dimensioned.

Verify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring diagram included in the manual.

Always verify that electric connections (cable entry, section of leads, protections…) are compliant with the electric specifications and with the instructions provided in the wiring scheme.

Always verify that all connections comply with the standards applicable to the installation of air conditioners.

Choosing the installation location

Indoor unit

For Wi-Fi Air-conditioner installation, select indoor unit location near to wireless router.

In case Wi-Fi signal strength weakened , Smart APP may be disconnected depending on the Wi-Fi signal strength.

Where airflow is not blocked.

Where cool air can be distributed throughout the room.

Install the refrigerant piping length and the height difference of both indoor and outdoor units as indicated in the installation diagram.

Wall that prevents vibration and is strong enough to hold the product weight.

Out of the direct sunlight .

1 m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated).

As far away as possible from the fluorescent and incandescent lights (so that the remote controller can be operated well).

A place where the air filter can be replaced easily.

Don't install directly above electronics equipment as leaking water may cause damage if not serviced. (eg. Computers, TV, etc).

English-36

MG_BETTER_INV_A3050_IB&IM_EN_DB68-05191A_UX.indd 36

2/17/2015 2:48:16 PM

Image 36
Contents Air Conditioner DB68-05191A-02Features of your new air conditioner Contents Safety precautions English-4English-5 01epPr arationFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9Checking before use Operation rangesEnglish-10 Technical Specifications English-11Wi-Fi indicator Timer / Auto Clean indicator Checking the name of the partsMain parts DisplayChecking the remote controller Remote controller buttonsEnglish-13 Remote controller display Low Battery warningStoring the remote controller Inserting the batteriesBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-16 Adjusting the air flow direction Remote controller displayRemote controller displayEnglish-17 Vertical air flow Horizontal air flowSetting the On/Off timer Setting the On timerWhen the air conditioner is off FfPress the Timer button select On press the or button Setting the Off timer English-19Er03mti ButtonAdditional options available in mode ModeEnglish-20 When the air conditioner is operating in Cool mode Step cooling functionEnglish-21 Press the Options buttonUsing the Fast function Using the Comfort functionWhen the air conditioner is operating in Cool/Heat mode English-22Using the Single user function English-23Using the Quiet function Make the Quiet indicator blink and press the SET buttonEnglish-24 Using the Virus Doctor function When the air conditioner is operatingWhen the air conditioner is not in operation Make the indicator blink and press the SET buttonChecking the power consumption Using the Auto clean functionLighting in Auto clean mode Make the Clean indicator blink and press the SET buttonSetting the Beep sound Resetting the Filter clean reminderSetting the Display option English-27Using the Smart A/C application English-28Cleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger English-29Cleaning the Air filter Removing the Air filterEnglish-30 Remove the Air filter from the main bodyReassembling the Air filter English-31Top of the Air filter into the main body.. ➀ Maintaining the air conditioner English-32Troubleshooting TemperatureAdjustment is not English-33Button or disconnect the power plug/switch Check the Drains have been cleared Regular MaintenanceError is indicated Heard when refrigerant flow movement changes. It is normalGeneral information English-3507stin llan atio Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker Indoor unitWhere sulfide gas exists Outdoor UnitEnglish-37 Reduce noise and vibrationWhen installing more than 1 outdoor unit When the air outlet is towards the wallEnglish-38  Figure DescriptionAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case English-39Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsAssembling the hanger screw English-41This QR code for detail video of indoor unit installation Removing the screwsRemoving the Cover panel Before mounting the indoor unit English-42Assembling the Cover panel After mounting the indoor unit English-43Connecting the assembly cable Cable specificationConnecting the cable English-44Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-45 English-46 Smooth the cut edgesCut off the remaining foam insulation TorqueEvacuating the indoor unit Cutting or extending the pipeEnglish-47 Unscrew the caps at the end of each pipeEnglish-48 Correct InclinedCracked Flare nutDrain hose installation English-49Change the direction only when it is necessary Changing direction of the drain hoseEnglish-50 Check for leakage on both side of the drain outletEvacuating the connected pipes English-51Outer Torque Outdoor unit Indoor unitAdding Refrigerant English-52Cylinder with siphon If you use a pipe longer than 5 mPerforming the gas leak tests English-53Outdoor unit installed on the wall by rack Fixing the outdoor unit in placeEnglish-54 660 340Smart Install mode English-55English-56 Off / Blinking / OnFinal check and trial operation English-57Packing and unpacking guide English-58How to connect your extended power cables English-59Apply heat to the contraction tube to contract it Atio After tube contraction work is completed, wrap it withQuestions or COMMENTS? 021-8255 CE