Samsung AF28FSSDAWKNBT Checking before use, Make sure that curtain does not block the air inlet

Page 12

Checking before use

Using indoor unit

Make sure that curtain does not block the air inlet.

ffIt may decrease cooling performance by blocking air circulation.

In Cool mode, set the appropriate desired temperature.

fIfthe desired temperature is too low, it may be harmful for human body and power consumption will also increase. Set the desired temperature about 5°C lower than the outdoor temperature.

Use extra heating apparatus during heat mode.

ffHeating performance of the air conditioner may decrease when the indoor•outdoor temperature drops. Therefore, use extra heating apparatus.

When cooling the room, use air conditioner and fan together to save energy.

ffWhen the air conditioner is used with fan, cooling will be more effective and energy can be saved.

When the air conditioner is operating, close the doors and windows.

ffWhen the air conditioner is used with open doors and windows, cooling effect will decrease.

fIfyou use the air conditioner for over an hour, open the window to ventilate the air about once every hour.

Install the product away from sunlight or heating devices. ffClose the curtain when the sun shines.

ffDo not use any heating devices during cooling operation. Cooling effect will decrease.

ENGLISH

Storing indoor unit

ffDry the air conditioner thoroughly by operating Purity mode for 3 to 4 hours. ffStop the operation and disconnect the power or turn off the auxiliary power switch.

• Do not move the product on your own. Pipe may get loose or pipe can get CAUTION damaged.

Using outdoor unit

Take away covers or barriers.

ffIt may cause product failure, and poor performance in cooling(heating) by blocking air flow.

Installing outdoor unit

ffInstall the outdoor unit in well ventilated area with no sunlight. If sunlight is unavoidable, install a sunshade.

11

칠레향 FAC MEMORY 냉난방_IBIM_EN_03892A(5).indd 11

2014-03-12 오전 9:32:57

Image 12
Contents Questions or COMMENTS? This product is RoHS compliantAir Conditioner Thank you for purchasing this Samsung productFeatures of your new air conditioner Seasons of effective cleaningSmart sensor Applicable to Affssd onlyContents Safety precautions Important safety symbols and precautionsInjury or death Injury or property damageFfThis may result in electric shock or fire For Power Supply Warning For Using FfThis may result in electric shock or burns Do not place objects or devices under the indoor unit Do not operate the appliance with wet handsDo not drink the water from the air conditioner For Cleaning Do not clean the inside of the air conditioner by yourselfCool mode, set the appropriate desired temperature Use extra heating apparatus during heat modeChecking before use Make sure that curtain does not block the air inletAuxiliary power switch Auxiliary power switch NFB, ELB, etcOperation ranges Functions available for each modelHeating capacity Checking the name of the parts Indoor unitDischarge cool air Display Buttons on control panelNumber of air outlets is different depending on the models Stop Press the Power Operation with control panelFan speed of each air outlet will differ Button one more timeChecking the remote controller Remote controller buttonsRemote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasic operation Press the button to set the operation mode Press the button to adjust the desired temperaturePress the button to turn on the air conditioner Solomode RemarksPress Button on the remote controller in the Cool/Heat mode Turbo operationAir flow direction Press the button to select desired air flow directionWhen the air conditioner is on and in cool mode Goodsleep operationTemperature and fan speed changes in goodsleep mode Setting the On/Off timer Additional options available in On timer modeGoodsleep functions Preset time on On timer is longer than Off timer Your air conditioner will turn onAir conditioner will turn on after 3 hours Press the button during Cool mode To adjust the lighting level of an indoor unitSmart sensor operation Lighting functionAuto clean operation Quiet operationCleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger Be careful with the sharp edges on the outdoor unitCleaning the Full HD filter Remove dust with a vacuum cleaner or running waterFull HD Filter filters the big dust of incoming air Pull out the Full HD filter in the arrow directionCleaning the Zero filter FfDo not disassemble the Zero filter when cleaning itDry the filter in a ventilated area Troubleshooting Controller after setting the time Clean the Zero filter and Full HD Filter if they are dirtySpeed Check if your batteries are depletedError is indicated Contact a service centerConditioner, push the Zero filter to the end Not worry about fire with thisOpen Source Announcement Installation parts Safety precautions Choosing the installation location Required toolsGeneral tools Tools for test operationsIndoor/outdoor unit installation diagram Installation space for floor type indoor unitPiping length for indoor/outdoor unit installation Fixing outdoor unit Outdoor unitConnecting the outdoor unit drain hose To make sure water is drained properlyAccessories Indoor unit accessoriesOutdoor unit accessories Installation accessoriesConnecting pipes Installation procedureDrilling a hole and fixing the indoor unit FfDrill a hole with diameter of 60~65mm towards the outsideFfFlare process FfFlare lengthFfIncorrectly flared pipes FfTightening of connection parts FfPipe insulationIndoor Use finishing tape wind up the refrigerant pipe DiameterDConnecting drain hose Connection with wire-concealed pipingFix the drain hose tightly to prevent any water leakage Wiring standard Connecting procedureIndoor power Indoor/outdoor unit power cable Electrical workSafety information on outdoor unit power supply Type of outdoor unit power supplyTorque Kgfcm 25~40How to connect your extended power cables FfItems to prepareApply heat to the contraction tube to contract it Vacuum pump Vacuuming pipeFfVacuuming air conditioner Performing leak test Test part for indoor unitNm = 10 kgfcm Outer Tightening torqueInstalling the earth wire Charging refrigerantCharge the refrigerant depending on the pipe length Check and test operation Disconnect the pipe