Samsung AF28FSZDAWKNMG, AF28FSSDAWKNFA, AF27FSSDAWKNER FfThis may result in electric shock or fire

Page 6

Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed.

ffFailing to do so may result in electric shock or fire.

Do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a location where gas may leak.

ffThis may result in electric shock or fire.

Never install the outdoor unit in a location such as on a high external wall where it could fall.

fIfthe outdoor unit falls, it may result in injury, death or property damage.

This appliance must be properly grounded. Do not ground the appliance to a gas pipe, plastic water pipe, or telephone line.

ffFailure to do so may result in electric shock, fire, an explosion, or other problems with the product.

ffMake sure to use a socket-outlet with ground.

ENGLISH

FOR INSTALLATION

CAUTION

Install your appliance on a level and hard floor that can support its weight. ffFailing to do so may result in abnormal vibrations, noise, or problems with the

product.

Confirm that the indoor unit fixing device has been installed by confirming this at an installation engineer.

fIfthe indoor unit fixing device is not installed, the indoor unit may vibrate and fall and this may result in injury.

5

칠레향 FAC MEMORY 냉난방_IBIM_EN_03892A(5).indd 5

2014-03-12 오전 9:32:56

Image 6
Contents Questions or COMMENTS? This product is RoHS compliantAir Conditioner Thank you for purchasing this Samsung productSmart sensor Features of your new air conditionerSeasons of effective cleaning Applicable to Affssd onlyContents Injury or death Safety precautionsImportant safety symbols and precautions Injury or property damageFfThis may result in electric shock or fire For Power Supply Warning For Using FfThis may result in electric shock or burns Do not place objects or devices under the indoor unit Do not operate the appliance with wet handsDo not drink the water from the air conditioner For Cleaning Do not clean the inside of the air conditioner by yourselfChecking before use Cool mode, set the appropriate desired temperatureUse extra heating apparatus during heat mode Make sure that curtain does not block the air inletOperation ranges Auxiliary power switchAuxiliary power switch NFB, ELB, etc Functions available for each modelHeating capacity Checking the name of the parts Indoor unitDischarge cool air Display Buttons on control panelNumber of air outlets is different depending on the models Fan speed of each air outlet will differ Stop Press the PowerOperation with control panel Button one more timeChecking the remote controller Remote controller buttonsStoring the remote controller Remote controller displayBattery changing time Inserting the batteriesBasic operation Press the button to turn on the air conditioner Press the button to set the operation modePress the button to adjust the desired temperature Solomode RemarksAir flow direction Press Button on the remote controller in the Cool/Heat modeTurbo operation Press the button to select desired air flow directionWhen the air conditioner is on and in cool mode Goodsleep operationTemperature and fan speed changes in goodsleep mode Setting the On/Off timer Additional options available in On timer modeGoodsleep functions Preset time on On timer is longer than Off timer Your air conditioner will turn onAir conditioner will turn on after 3 hours Smart sensor operation Press the button during Cool modeTo adjust the lighting level of an indoor unit Lighting functionAuto clean operation Quiet operationCleaning the outdoor unit heat exchanger Cleaning the air conditionerCleaning the indoor unit Be careful with the sharp edges on the outdoor unitFull HD Filter filters the big dust of incoming air Cleaning the Full HD filterRemove dust with a vacuum cleaner or running water Pull out the Full HD filter in the arrow directionCleaning the Zero filter FfDo not disassemble the Zero filter when cleaning itDry the filter in a ventilated area Troubleshooting Speed Controller after setting the timeClean the Zero filter and Full HD Filter if they are dirty Check if your batteries are depletedConditioner, push the Zero filter to the end Error is indicatedContact a service center Not worry about fire with thisOpen Source Announcement Installation parts Safety precautions General tools Choosing the installation locationRequired tools Tools for test operationsIndoor/outdoor unit installation diagram Installation space for floor type indoor unitPiping length for indoor/outdoor unit installation Fixing outdoor unit Outdoor unitConnecting the outdoor unit drain hose To make sure water is drained properlyOutdoor unit accessories AccessoriesIndoor unit accessories Installation accessoriesDrilling a hole and fixing the indoor unit Connecting pipesInstallation procedure FfDrill a hole with diameter of 60~65mm towards the outsideFfFlare process FfFlare lengthFfIncorrectly flared pipes Indoor Use finishing tape wind up the refrigerant pipe FfTightening of connection partsFfPipe insulation DiameterDConnecting drain hose Connection with wire-concealed pipingFix the drain hose tightly to prevent any water leakage Indoor power Indoor/outdoor unit power cable Wiring standardConnecting procedure Electrical workTorque Safety information on outdoor unit power supplyType of outdoor unit power supply Kgfcm 25~40How to connect your extended power cables FfItems to prepareApply heat to the contraction tube to contract it Vacuum pump Vacuuming pipeFfVacuuming air conditioner Nm = 10 kgfcm Performing leak testTest part for indoor unit Outer Tightening torqueInstalling the earth wire Charging refrigerantCharge the refrigerant depending on the pipe length Check and test operation Disconnect the pipe