Installing the earth wire
Earthing must be done by the installation specialist for your safety. ffConnect grounding electrode and the air conditioner.
Charging refrigerant
1.Connect the manifold gauge in the low pressure side (gas) and press Set/Cancel, Mode, Temp + button simultaneously for 5 seconds to enter the refrigerant charging mode. When the outdoor unit operates, charge the refrigerant.
2.Charge the refrigerant depending on the pipe length.
Manifold gauge
Gas side |
|
Liquid side | Refrigerant |
|
Electronic scale
3.After charging the refrigerant, disconnect the manifold gauge from the service port and close the service cap.
4.Deactivate the refrigerant charging mode by pressing Set/Cancel, Mode, Temp + button simultaneously for 5 seconds.
• Make sure to charge refrigerant with accurate amount by using the electronic scale.
CAUTION
52
칠레향 FAC MEMORY 냉난방_IBIM_EN_03892A(5).indd 52 |