Samsung AF28FSSDADFNMG manual Connecting drain hose, Connection with wire-concealed piping

Page 46

Connecting drain hose

1.Slightly hit the hole, for drain hose, with your hands or hammer.

2.Insulate the drain hose with drain insulation tube and fix it with tape.

3.Direct the drain hose downward to establish natural draining. -- Make sure to check for proper drainage after connection

• Fix the drain hose tightly to prevent any water leakage.

CAUTION • Do not use the extended drain hose.

-- Since water may leak from the connection part, make sure that you do not extend the drain hose. However, if extension is unavoidable due to its short length, use silicone sealant to securely seal the connection to prevent leakage. (Do not use the insulation tape.)

Drain hose

Duct drainage [Polypropylene(PP)]

Insulation (foamed polyethylene)

Connection drain hose

ENGLISH

Connect the drain hose through the upper hole for drain hose.

Upper hole for a drain hose Drain hose

mm410 Piping

Hole for piping connection

• Connection with wire-concealed piping

Incorrect installation

Upper hole for a drain hose Drain hose (U-TRAP)

Piping

Hole for piping connection

• Make sure the U-TRAP does not occur. Water may overflow and cause property damage.

CAUTION

45

칠레향 FAC MEMORY 냉난방_IBIM_EN_03892A(5).indd 45

2014-03-12 오전 9:33:15

Image 46
Contents Questions or COMMENTS? This product is RoHS compliantAir Conditioner Thank you for purchasing this Samsung productSmart sensor Features of your new air conditionerSeasons of effective cleaning Applicable to Affssd onlyContents Injury or death Safety precautionsImportant safety symbols and precautions Injury or property damageFfThis may result in electric shock or fire For Power Supply Warning For Using FfThis may result in electric shock or burns Do not operate the appliance with wet hands Do not place objects or devices under the indoor unitDo not drink the water from the air conditioner For Cleaning Do not clean the inside of the air conditioner by yourselfChecking before use Cool mode, set the appropriate desired temperatureUse extra heating apparatus during heat mode Make sure that curtain does not block the air inletOperation ranges Auxiliary power switchAuxiliary power switch NFB, ELB, etc Functions available for each modelHeating capacity Indoor unit Checking the name of the partsDischarge cool air Buttons on control panel DisplayNumber of air outlets is different depending on the models Fan speed of each air outlet will differ Stop Press the PowerOperation with control panel Button one more timeChecking the remote controller Remote controller buttonsStoring the remote controller Remote controller displayBattery changing time Inserting the batteriesBasic operation Press the button to turn on the air conditioner Press the button to set the operation modePress the button to adjust the desired temperature Solomode RemarksAir flow direction Press Button on the remote controller in the Cool/Heat modeTurbo operation Press the button to select desired air flow directionWhen the air conditioner is on and in cool mode Goodsleep operationTemperature and fan speed changes in goodsleep mode Additional options available in On timer mode Setting the On/Off timerGoodsleep functions Your air conditioner will turn on Preset time on On timer is longer than Off timerAir conditioner will turn on after 3 hours Smart sensor operation Press the button during Cool modeTo adjust the lighting level of an indoor unit Lighting functionAuto clean operation Quiet operationCleaning the outdoor unit heat exchanger Cleaning the air conditionerCleaning the indoor unit Be careful with the sharp edges on the outdoor unitFull HD Filter filters the big dust of incoming air Cleaning the Full HD filterRemove dust with a vacuum cleaner or running water Pull out the Full HD filter in the arrow directionFfDo not disassemble the Zero filter when cleaning it Cleaning the Zero filterDry the filter in a ventilated area Troubleshooting Speed Controller after setting the timeClean the Zero filter and Full HD Filter if they are dirty Check if your batteries are depletedConditioner, push the Zero filter to the end Error is indicatedContact a service center Not worry about fire with thisOpen Source Announcement Installation parts Safety precautions General tools Choosing the installation locationRequired tools Tools for test operationsInstallation space for floor type indoor unit Indoor/outdoor unit installation diagramPiping length for indoor/outdoor unit installation Fixing outdoor unit Outdoor unitConnecting the outdoor unit drain hose To make sure water is drained properlyOutdoor unit accessories AccessoriesIndoor unit accessories Installation accessoriesDrilling a hole and fixing the indoor unit Connecting pipesInstallation procedure FfDrill a hole with diameter of 60~65mm towards the outsideFfFlare length FfFlare processFfIncorrectly flared pipes Indoor Use finishing tape wind up the refrigerant pipe FfTightening of connection partsFfPipe insulation DiameterDConnection with wire-concealed piping Connecting drain hoseFix the drain hose tightly to prevent any water leakage Indoor power Indoor/outdoor unit power cable Wiring standardConnecting procedure Electrical workTorque Safety information on outdoor unit power supplyType of outdoor unit power supply Kgfcm 25~40How to connect your extended power cables FfItems to prepareApply heat to the contraction tube to contract it Vacuuming pipe Vacuum pumpFfVacuuming air conditioner Nm = 10 kgfcm Performing leak testTest part for indoor unit Outer Tightening torqueCharging refrigerant Installing the earth wireCharge the refrigerant depending on the pipe length Check and test operation Disconnect the pipe