Samsung AF28FSSDADFNFA manual Performing leak test, Test part for indoor unit, Nm = 10 kgfcm

Page 52

Performing leak test

ffUse leak tester or soapsuds on the pipe connection part after performing vacuum pump.

Check for

Check for

leakage

 

leakage

Test part for indoor unit

Test part for outdoor unit

ffBefore inspecting the leakage, use a torque wrench to close the cap for the service valve.(Comply with a tightening torque for each size of the diameter, and tighten the cap firmly to prevent any leakage.)

ffTo check for any possible leakage, insert inert gas into the pipes connected to indoor/outdoor units and check the connection part of the indoor/outdoor units with soap lather or liquid for leakage test.

ENGLISH

Tightening torque for body cap (Refer to the table)

Spindle

Charging core

R-22: Diameter of the screw - 7/16-20UNF

R-410A: Diameter of the screw - 1/2-20UNF

Tightening torque for charging port cap (Refer to the table)

Outer

Tightening torque

 

 

Diameter

Body cap

Charging port

(mm)

(N•m)

cap (N•m)

 

 

 

Ø6.35

20 ~ 25

 

Ø9.52

20 ~ 25

 

Ø12.7

25 ~ 30

10 ~ 12

Ø15.88

30 ~ 35

 

Ø19.05

35 ~ 40

 

❋❋1 N•m = 10 kgf•cm

51

칠레향 FAC MEMORY 냉난방_IBIM_EN_03892A(5).indd 51

2014-03-12 오전 9:33:18

Image 52
Contents Questions or COMMENTS? This product is RoHS compliantAir Conditioner Thank you for purchasing this Samsung productFeatures of your new air conditioner Seasons of effective cleaningSmart sensor Applicable to Affssd onlyContents Safety precautions Important safety symbols and precautionsInjury or death Injury or property damageFfThis may result in electric shock or fire For Power Supply Warning For Using FfThis may result in electric shock or burns Do not operate the appliance with wet hands Do not place objects or devices under the indoor unitDo not drink the water from the air conditioner For Cleaning Do not clean the inside of the air conditioner by yourselfCool mode, set the appropriate desired temperature Use extra heating apparatus during heat modeChecking before use Make sure that curtain does not block the air inletAuxiliary power switch Auxiliary power switch NFB, ELB, etcOperation ranges Functions available for each modelHeating capacity Indoor unit Checking the name of the partsDischarge cool air Buttons on control panel DisplayNumber of air outlets is different depending on the models Stop Press the Power Operation with control panelFan speed of each air outlet will differ Button one more timeChecking the remote controller Remote controller buttonsRemote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasic operation Press the button to set the operation mode Press the button to adjust the desired temperaturePress the button to turn on the air conditioner Solomode RemarksPress Button on the remote controller in the Cool/Heat mode Turbo operationAir flow direction Press the button to select desired air flow directionWhen the air conditioner is on and in cool mode Goodsleep operationTemperature and fan speed changes in goodsleep mode Additional options available in On timer mode Setting the On/Off timerGoodsleep functions Your air conditioner will turn on Preset time on On timer is longer than Off timerAir conditioner will turn on after 3 hours Press the button during Cool mode To adjust the lighting level of an indoor unitSmart sensor operation Lighting functionAuto clean operation Quiet operationCleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger Be careful with the sharp edges on the outdoor unitCleaning the Full HD filter Remove dust with a vacuum cleaner or running waterFull HD Filter filters the big dust of incoming air Pull out the Full HD filter in the arrow directionFfDo not disassemble the Zero filter when cleaning it Cleaning the Zero filterDry the filter in a ventilated area Troubleshooting Controller after setting the time Clean the Zero filter and Full HD Filter if they are dirtySpeed Check if your batteries are depletedError is indicated Contact a service centerConditioner, push the Zero filter to the end Not worry about fire with thisOpen Source Announcement Installation parts Safety precautions Choosing the installation location Required toolsGeneral tools Tools for test operationsInstallation space for floor type indoor unit Indoor/outdoor unit installation diagramPiping length for indoor/outdoor unit installation Fixing outdoor unit Outdoor unitConnecting the outdoor unit drain hose To make sure water is drained properlyAccessories Indoor unit accessoriesOutdoor unit accessories Installation accessoriesConnecting pipes Installation procedureDrilling a hole and fixing the indoor unit FfDrill a hole with diameter of 60~65mm towards the outsideFfFlare length FfFlare processFfIncorrectly flared pipes FfTightening of connection parts FfPipe insulationIndoor Use finishing tape wind up the refrigerant pipe DiameterDConnection with wire-concealed piping Connecting drain hoseFix the drain hose tightly to prevent any water leakage Wiring standard Connecting procedureIndoor power Indoor/outdoor unit power cable Electrical workSafety information on outdoor unit power supply Type of outdoor unit power supplyTorque Kgfcm 25~40How to connect your extended power cables FfItems to prepareApply heat to the contraction tube to contract it Vacuuming pipe Vacuum pumpFfVacuuming air conditioner Performing leak test Test part for indoor unitNm = 10 kgfcm Outer Tightening torqueCharging refrigerant Installing the earth wireCharge the refrigerant depending on the pipe length Check and test operation Disconnect the pipe