PROBLEM

SOLUTION

 

 

Air flow

• Check if you have selected good'sleep mode. In this mode, you

adjustment is not

cannot adjust the air flow direction since it is set to Auto.

working.

 

 

 

Fan speed

• Check if you have selected Dry/Turbo/good'sleep mode. In these

adjustment is not

modes, fan speed is set to Auto and you cannot adjust the fan

working.

speed.

 

 

 

• Check if your batteries are depleted.

 

• Make sure nothing is blocking your remote controller sensor.

Remote

• Check whether there are strong lighting apparatus near the air

conditioner. Strong light which comes from fluorescent bulbs or

controller is not

neon signs may interrupt the electric waves.

working.

• Stand towards the center of the product, point the remote

 

 

controller towards the remote control receiver and press the

 

button.

 

 

Timer function

• Check if you have pressed the Set/Cancel button on the remote

does not work.

controller after setting the time.

 

 

The air

• Check the air conditioner is in auto cleaning mode. When turning

conditioner is not

the air conditioner off after using the auto cleaning function, it

turned off.

will take 3 minutes to turn the air conditioner off.

 

 

 

• Odor may permeate depending on the surrounding environment

Odors permeate

or operating condition. Ventilate the indoor air.

• Check if the appliance is running in a smoky area. Ventilate the

in the room

room or operate the air conditioner in Purity mode for 1~2

during operation.

hours. (We do not use smelly components in the air conditioner.)

 

 

• Clean the Zero filter and Full HD Filter if they are dirty.

 

 

32

칠레향 FAC MEMORY 냉난방_IBIM_EN_03892A(5).indd 32

2014-03-12 오전 9:33:09

Image 33
Contents This product is RoHS compliant Questions or COMMENTS?Thank you for purchasing this Samsung product Air ConditionerSeasons of effective cleaning Features of your new air conditionerSmart sensor Applicable to Affssd onlyContents Important safety symbols and precautions Safety precautionsInjury or death Injury or property damageFfThis may result in electric shock or fire For Power Supply Warning For Using FfThis may result in electric shock or burns Do not place objects or devices under the indoor unit Do not operate the appliance with wet handsDo not drink the water from the air conditioner Do not clean the inside of the air conditioner by yourself For CleaningUse extra heating apparatus during heat mode Cool mode, set the appropriate desired temperatureChecking before use Make sure that curtain does not block the air inletAuxiliary power switch NFB, ELB, etc Auxiliary power switchOperation ranges Functions available for each modelHeating capacity Checking the name of the parts Indoor unitDischarge cool air Display Buttons on control panelNumber of air outlets is different depending on the models Operation with control panel Stop Press the PowerFan speed of each air outlet will differ Button one more timeRemote controller buttons Checking the remote controllerBattery changing time Remote controller displayStoring the remote controller Inserting the batteriesBasic operation Press the button to adjust the desired temperature Press the button to set the operation modePress the button to turn on the air conditioner Solomode RemarksTurbo operation Press Button on the remote controller in the Cool/Heat modeAir flow direction Press the button to select desired air flow directionGoodsleep operation When the air conditioner is on and in cool modeTemperature and fan speed changes in goodsleep mode Setting the On/Off timer Additional options available in On timer modeGoodsleep functions Preset time on On timer is longer than Off timer Your air conditioner will turn onAir conditioner will turn on after 3 hours To adjust the lighting level of an indoor unit Press the button during Cool modeSmart sensor operation Lighting functionQuiet operation Auto clean operationCleaning the indoor unit Cleaning the air conditionerCleaning the outdoor unit heat exchanger Be careful with the sharp edges on the outdoor unitRemove dust with a vacuum cleaner or running water Cleaning the Full HD filterFull HD Filter filters the big dust of incoming air Pull out the Full HD filter in the arrow directionCleaning the Zero filter FfDo not disassemble the Zero filter when cleaning itDry the filter in a ventilated area Troubleshooting Clean the Zero filter and Full HD Filter if they are dirty Controller after setting the timeSpeed Check if your batteries are depletedContact a service center Error is indicatedConditioner, push the Zero filter to the end Not worry about fire with thisOpen Source Announcement Installation parts Safety precautions Required tools Choosing the installation locationGeneral tools Tools for test operationsIndoor/outdoor unit installation diagram Installation space for floor type indoor unitPiping length for indoor/outdoor unit installation Outdoor unit Fixing outdoor unitTo make sure water is drained properly Connecting the outdoor unit drain hoseIndoor unit accessories AccessoriesOutdoor unit accessories Installation accessoriesInstallation procedure Connecting pipesDrilling a hole and fixing the indoor unit FfDrill a hole with diameter of 60~65mm towards the outsideFfFlare process FfFlare lengthFfIncorrectly flared pipes FfPipe insulation FfTightening of connection partsIndoor Use finishing tape wind up the refrigerant pipe DiameterDConnecting drain hose Connection with wire-concealed pipingFix the drain hose tightly to prevent any water leakage Connecting procedure Wiring standardIndoor power Indoor/outdoor unit power cable Electrical workType of outdoor unit power supply Safety information on outdoor unit power supplyTorque Kgfcm 25~40FfItems to prepare How to connect your extended power cablesApply heat to the contraction tube to contract it Vacuum pump Vacuuming pipeFfVacuuming air conditioner Test part for indoor unit Performing leak testNm = 10 kgfcm Outer Tightening torqueInstalling the earth wire Charging refrigerantCharge the refrigerant depending on the pipe length Disconnect the pipe Check and test operation