Samsung AR18KRJSBWKNMG, AR18MQJSBWKXMG, AR18MRJSBWKXMG, AR18MRJSBWKNMG manual Model AR24KRJSRWK/MG

Page 28

MODEL

 

AR24KRJSRWK/MG

 

 

AR24KQJSBWK/MG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLIMATES CLASS

 

T1

 

T3

 

 

T1

 

T3

 

 

 

 

 

 

 

 

 

 

 

 

 

CAPACITY

COOLING

22000 Btu/h

 

18000 Btu/h

22000 Btu/h

 

18000 Btu/h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING (H1)

 

 

 

-

 

 

 

 

6300 W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED VOLTAGE & FREQUENCY

 

 

230 V ~ 60 Hz

 

 

 

230 V ~ 60 Hz

 

RATED CURRENT

COOLING

8.5 A

 

9.5 A

 

8.5 A

 

9.5 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING (H1)

 

 

 

-

 

 

 

 

8.7 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED POWER

COOLING

1910 W

 

2170 W

 

1910 W

 

2170 W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

HEATING (H1)

 

 

 

-

 

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EER/COP

COOLING

11.50 (Btu/hr)/W

8.30 (Btu/hr)/W

11.52 (Btu/hr)/W

8.29 (Btu/hr)/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING (H1)

 

 

 

-

 

 

 

 

3.21 W/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFRIGERANT

TYPE

 

 

R-410A

 

 

 

R-410A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHARGE

 

 

1020 g [35.98 oz]

 

 

2000 g [70.54 oz]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ANNUAL ENERGY CONSUMPTION

 

 

5157 kWh/Year

 

 

 

5157 kWh/Year

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR

27˚C

 

-

 

29˚C

 

-

27˚C

 

20˚C

 

29˚C

 

20˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE

19˚C

 

-

 

19˚C

 

-

19˚C

 

15˚C

 

19˚C

 

15˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

35˚C

 

-

 

46˚C

 

-

35˚C

 

7˚C

 

46˚C

 

7˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24˚C

 

-

 

24˚C

 

-

24˚C

 

6˚C

 

24˚C

 

6˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NET WEIGHT

INDOOR

 

 

14.5 kg

 

 

 

14.5 kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

 

 

52.5 kg

 

 

 

64.0 kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS OF

INDOOR

 

1065 x 301 x 294 mm

 

1065 x 301 x 294 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THE UNIT

OUTDOOR

 

880 x 793 x 310 mm

 

880 x 967 x 320 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COUNTRY OF ORIGIN

 

 

THAILAND

 

 

 

CHINA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cleaning and Maintenance

English 27

Image 28 Contents
Questions or COMMENTS? Airconditioner DB68-06070A-01Contents Correct Disposal of This Product Failing to do so may result in electric shock or fire Safety InformationThis may result in electric shock or fire For Power Supply Do not touch the circuit breakerwith wet hands This may result in electric shockThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not place objects or devices under the indoor unit Do not operate the appliance with wet handsDo not drink the water from the air conditioner Do not touch the pipes connected with the productFor Cleaning Do not clean the inside of the air conditioner by yourselfOperation indicator Single user indicatorIndoor Unit Overview DisplayRemote Control Overview Inserting batteriesControlling temperature Remote Control OperationOperation modes Controlling fan speed Controlling air flow directionCooling Operation Cool modeStep cooling function Dry mode Dehumidifying OperationHeat mode Heating OperationAuto mode Quick Smart FeaturesFan mode Fast function Comfort function Beep sound functionEnergy-Saving Operation Single user functionTimed on/Timed off function Default operation time for the good’sleep function Good’sleep functionCleaning at a Glance Running Auto cleanCleaning duration minutes Do not clean the display by using alkaline detergentCleaning the filter Troubleshooting Indicator blinks Check whether the drains are clean. Clean them regularlyTo pass the error code to the service centre Does not work35˚C Technical Specifications24˚C Model AR24KRJSRWK/MG AR18MRJSBWK/MG AR18MQJSBWK/MG Model AR24MRJSRWK/MG Installation of the unit Safety Information on InstallationGeneral information Power supply line, fuse, or circuit breaker Install the unit in a place where water can drain smoothlyPreparation Choosing the installation locationMinimum clearances for the outdoor unit Indoor unit Packing and UnpackingOutdoor unit Accessories in the indoor unit package Checking and preparing accessories and tools AccessoriesOptional accessories Drilling a hole through the wall Accessories in the outdoor unit packageTools Taping the pipes, cables, and drain hose Indoor Unit Installation Disassembling the installation plateDisassembling the cover panel Remove the cap screws, then the screwsConnecting the cables assembly cable Optional Extending the power cable Compression dimension should bePrepare the following tools Apply heat to the contraction tube to contract itInstalling and connecting the drain hose Incomplete wireInstall the drain hose Optional Extending the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe Depth aWhen fixing the indoor unit on a wall 10 Fixing the installation plateWhen fixing the indoor unit on a window frame 11 Fixing the indoor unit to the installation plate When fixing the indoor unit on a gypsum boardFix the installation plate without inclining to one side 12 Assembling the cover panelOutdoor Unit Installation Connecting the cables and the refrigerant pipesFixing the outdoor unit in place Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Leave the system in the standby modeCooling capacity and malfunction. Use a vacuum pump Adding refrigerant SiphonRunning the Smart Install mode Installation InspectionPerforming the gas leak tests Error indicator Error Measures for the installer to take DisplayMotor Connector Remove foreign substance. Check Blocking error OpenCheck the following Strength of the installation site Turn on th air conditioner and select Fast Cool modePerforming final check and trial operation Pumping down refrigerant
Related manuals
Manual 51 pages 22.32 Kb