Samsung AR24KRJSRWKNMG, AR18MQJSBWKXMG manual Packing and Unpacking, Indoor unit, Outdoor unit

Page 34

When installing more than 1 outdoor unit

(5 cases)

 

 

 

 

 

(Unit: mm)

1500

600

3000

3000

200

 

 

 

 

 

300

 

 

600

 

600

1500

 

 

 

 

 

1500

 

 

 

 

 

300

 

300

600

600

600

 

 

 

500

300

 

 

 

 

 

 

 

 

 

500

300

 

 

 

 

 

 

 

 

CAUTION

If the outdoor unit is installed with any insufficient clearance, it may generate sound and affect the whole product.

Be sure to install the outdoor unit in a level place where its vibration does not affect the whole product.

Step 1.2 Packing and Unpacking

indoor unit

Packing the unit as below procedure

1Put the indoor unit onto the packing case.

2Assemble cushion-both side of indoor unit. (Left and Right)

3Seal the packing case.

Unpacking the unit as below procedure

1Open the packing case.

2Take out the both side of cushion(Left and Right).

3Move the set from the packing case.

Outdoor unit

Packing the unit as below procedure

1Put the outdoor unit onto the cushion-bottom.

2Put the cushion-top onto the outdoor unit

3Put the packing case from the top of set.

4Seal the packing case.

Unpacking the unit as below procedure

1Take out the packing case from the set.

2Take out the cushion-top.

3Move the set from the cushion-bottom.

Installation

English 33

Image 34 Contents
Questions or COMMENTS? Airconditioner DB68-06070A-01Contents Correct Disposal of This Product Failing to do so may result in electric shock or fire Safety InformationThis may result in electric shock or fire For Power Supply This may result in electric shock or burns Do not touch the circuit breakerwith wet handsThis may result in electric shock This may result in children seriously injuring themselvesDo not drink the water from the air conditioner Do not place objects or devices under the indoor unitDo not operate the appliance with wet hands Do not touch the pipes connected with the productFor Cleaning Do not clean the inside of the air conditioner by yourselfIndoor Unit Overview Operation indicatorSingle user indicator DisplayRemote Control Overview Inserting batteriesControlling temperature Remote Control OperationOperation modes Controlling fan speed Controlling air flow directionCooling Operation Cool modeStep cooling function Dry mode Dehumidifying OperationHeat mode Heating OperationAuto mode Quick Smart FeaturesFan mode Fast function Comfort function Beep sound functionEnergy-Saving Operation Single user functionTimed on/Timed off function Default operation time for the good’sleep function Good’sleep functionCleaning duration minutes Cleaning at a GlanceRunning Auto clean Do not clean the display by using alkaline detergentCleaning the filter Troubleshooting To pass the error code to the service centre Indicator blinksCheck whether the drains are clean. Clean them regularly Does not work35˚C Technical Specifications24˚C Model AR24KRJSRWK/MG AR18MRJSBWK/MG AR18MQJSBWK/MG Model AR24MRJSRWK/MG Installation of the unit Safety Information on InstallationGeneral information Power supply line, fuse, or circuit breaker Install the unit in a place where water can drain smoothlyPreparation Choosing the installation locationMinimum clearances for the outdoor unit Indoor unit Packing and UnpackingOutdoor unit Accessories in the indoor unit package Checking and preparing accessories and tools AccessoriesOptional accessories Drilling a hole through the wall Accessories in the outdoor unit packageTools Taping the pipes, cables, and drain hose Disassembling the cover panel Indoor Unit InstallationDisassembling the installation plate Remove the cap screws, then the screwsConnecting the cables assembly cable Prepare the following tools Optional Extending the power cableCompression dimension should be Apply heat to the contraction tube to contract itInstall the drain hose Installing and connecting the drain hoseIncomplete wire Optional Extending the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe Depth aWhen fixing the indoor unit on a wall 10 Fixing the installation plateWhen fixing the indoor unit on a window frame Fix the installation plate without inclining to one side 11 Fixing the indoor unit to the installation plateWhen fixing the indoor unit on a gypsum board 12 Assembling the cover panelFixing the outdoor unit in place Outdoor Unit InstallationConnecting the cables and the refrigerant pipes Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Leave the system in the standby modeCooling capacity and malfunction. Use a vacuum pump Adding refrigerant SiphonRunning the Smart Install mode Installation InspectionPerforming the gas leak tests Motor Connector Remove foreign substance. Check Error indicatorError Measures for the installer to take Display Blocking error OpenPerforming final check and trial operation Check the following Strength of the installation siteTurn on th air conditioner and select Fast Cool mode Pumping down refrigerant
Related manuals
Manual 51 pages 22.32 Kb