Samsung AR24KRJSRWKNMG, AR18MQJSBWKXMG, AR18MRJSBWKXMG manual Correct Disposal of This Product

Page 4

Indoor Unit Installation

37

Step 2.1 Disassembling the cover panel

 

Step 2.2

Disassembling the installation plate

 

Step 2.3

Connecting the cables (assembly cable)

 

Step 2.4

Optional: Extending the power cable

 

Step 2.5 Installing and connecting the drain hose Step 2.6 Optional: Extending the drain hose

Step 2.7 Optional: Changing the direction of the drain hose

Step 2.8 Installing and connecting the assembly pipes to the refrigerant pipes (assembly pipe) Step 2.9 Shortening or extending the refrigerant pipes (assembly pipe)

Step 2.10 Fixing the installation plate

Step 2.11 Fixing the indoor unit to the installation plate Step 2.12 Assembling the cover panel

Outdoor Unit Installation

45

Step 3.1 Fixing the outdoor unit in place

 

Step 3.2

Connecting the cables and the refrigerant pipes

 

Step 3.3

Evacuating the air

 

Step 3.4

Adding refrigerant

 

Installation Inspection

48

Step 4.1 Performing the gas leak tests

 

Step 4.2 Running the Smart Install mode

 

Step 4.3 Performing final check and trial operation

 

 

 

 

 

 

 

 

 

 

 

 

Correct Disposal of This Product

 

 

 

 

 

 

 

 

 

 

(Waste Electrical & Electronic Equipment)

 

 

 

 

 

 

 

 

 

 

(Applicable in countries with separate collection systems)

This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources.

Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take these items for environmentally safe recycling.

Business users should contact their supplier and check the terms and conditions of the purchase contract. This product and its electronic accessories should not be mixed with other commercial wastes for disposal.

Correct disposal of batteries in this product This marking on the battery, manual or packaging indicates that the batteries in this product should not be disposed of with other household waste at the end of theirworking life. Where marked, the chemical symbols Hg, Cd or Pb indicate that the battery contains mercury, cadmium or lead above the reference levels in EC Directive 2006/66.

English 3

Image 4
Contents Questions or COMMENTS? Airconditioner DB68-06070A-01Contents Correct Disposal of This Product Failing to do so may result in electric shock or fire Safety InformationThis may result in electric shock or fire For Power Supply Do not touch the circuit breakerwith wet hands This may result in electric shockThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not place objects or devices under the indoor unit Do not operate the appliance with wet handsDo not drink the water from the air conditioner Do not touch the pipes connected with the productFor Cleaning Do not clean the inside of the air conditioner by yourselfOperation indicator Single user indicatorIndoor Unit Overview DisplayRemote Control Overview Inserting batteriesControlling temperature Remote Control OperationOperation modes Controlling fan speed Controlling air flow directionCooling Operation Cool modeStep cooling function Dry mode Dehumidifying OperationHeat mode Heating OperationAuto mode Quick Smart FeaturesFan mode Fast function Comfort function Beep sound functionEnergy-Saving Operation Single user functionTimed on/Timed off function Default operation time for the good’sleep function Good’sleep functionCleaning at a Glance Running Auto cleanCleaning duration minutes Do not clean the display by using alkaline detergentCleaning the filter Troubleshooting Indicator blinks Check whether the drains are clean. Clean them regularlyTo pass the error code to the service centre Does not work35˚C Technical Specifications24˚C Model AR24KRJSRWK/MG AR18MRJSBWK/MG AR18MQJSBWK/MG Model AR24MRJSRWK/MG Installation of the unit Safety Information on InstallationGeneral information Power supply line, fuse, or circuit breaker Install the unit in a place where water can drain smoothlyPreparation Choosing the installation locationMinimum clearances for the outdoor unit Indoor unit Packing and UnpackingOutdoor unit Accessories in the indoor unit package Checking and preparing accessories and tools AccessoriesOptional accessories Drilling a hole through the wall Accessories in the outdoor unit packageTools Taping the pipes, cables, and drain hose Indoor Unit Installation Disassembling the installation plateDisassembling the cover panel Remove the cap screws, then the screwsConnecting the cables assembly cable Optional Extending the power cable Compression dimension should bePrepare the following tools Apply heat to the contraction tube to contract itInstalling and connecting the drain hose Incomplete wireInstall the drain hose Optional Extending the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe Depth aWhen fixing the indoor unit on a wall 10 Fixing the installation plateWhen fixing the indoor unit on a window frame 11 Fixing the indoor unit to the installation plate When fixing the indoor unit on a gypsum boardFix the installation plate without inclining to one side 12 Assembling the cover panelOutdoor Unit Installation Connecting the cables and the refrigerant pipesFixing the outdoor unit in place Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Leave the system in the standby modeCooling capacity and malfunction. Use a vacuum pump Adding refrigerant SiphonRunning the Smart Install mode Installation InspectionPerforming the gas leak tests Error indicator Error Measures for the installer to take DisplayMotor Connector Remove foreign substance. Check Blocking error OpenCheck the following Strength of the installation site Turn on th air conditioner and select Fast Cool modePerforming final check and trial operation Pumping down refrigerant