Samsung AR24MRJSRWK/MG Outdoor Unit Installation, Connecting the cables and the refrigerant pipes

Page 46

Outdoor Unit Installation

Step 3.1 Fixing the outdoor unit in place

X

Y

Rubber leg

 

 

(Unit : mm)

 

 

 

Model

X

Y

 

 

 

✴✴18✴✴

660

340

✴✴24KR/MR✴✴

 

 

 

 

 

✴✴24KQ✴✴

645

340

 

 

 

1Place the outdoor unit as directed on the top of the unit to let the discharged air out properly.

2Fix the outdoor unit in level to an appropriate support using anchor bolts.

NOTE

Secure the rubber legs to help prevent the generation of noise and vibration.

If the outdoor unit is exposed to strong winds, install shield plates around the outdoor unit so that the fan can operate correctly.

NOTE

Make sure that the wall can support the weights of the rack and the outdoor unit.

Install the rack close to the column as much as possible.

Step 3.2 Connecting the cables and the refrigerant pipes

✴✴18KR/MR✴✴✴✴24✴✴

N(1)

1

N(1)

1

2

✴✴18KQ/MQ✴✴

N(1)

1

2

3

Optional: Fixing the outdoor unit to a wall with a rack

Soft rubber designed to cut off vibration from rack to wall (not supplied with product)

CAUTION

• Be sure to fix the power cables and communication cable with a cable clamp.

Installation

Soft rubber designed to cut off residual vibration from outdoor unit to rack (not supplied with product)

English 45

Image 46
Contents Questions or COMMENTS? Airconditioner DB68-06070A-01Contents Correct Disposal of This Product Failing to do so may result in electric shock or fire Safety InformationThis may result in electric shock or fire For Power Supply This may result in electric shock or burns Do not touch the circuit breakerwith wet handsThis may result in electric shock This may result in children seriously injuring themselvesDo not drink the water from the air conditioner Do not place objects or devices under the indoor unitDo not operate the appliance with wet hands Do not touch the pipes connected with the productFor Cleaning Do not clean the inside of the air conditioner by yourselfIndoor Unit Overview Operation indicatorSingle user indicator DisplayRemote Control Overview Inserting batteriesControlling temperature Remote Control OperationOperation modes Controlling fan speed Controlling air flow directionCooling Operation Cool modeStep cooling function Dry mode Dehumidifying OperationHeat mode Heating OperationAuto mode Quick Smart FeaturesFan mode Fast function Comfort function Beep sound functionEnergy-Saving Operation Single user functionTimed on/Timed off function Default operation time for the good’sleep function Good’sleep functionCleaning duration minutes Cleaning at a GlanceRunning Auto clean Do not clean the display by using alkaline detergentCleaning the filter Troubleshooting To pass the error code to the service centre Indicator blinksCheck whether the drains are clean. Clean them regularly Does not work35˚C Technical Specifications24˚C Model AR24KRJSRWK/MG AR18MRJSBWK/MG AR18MQJSBWK/MG Model AR24MRJSRWK/MG Installation of the unit Safety Information on InstallationGeneral information Power supply line, fuse, or circuit breaker Install the unit in a place where water can drain smoothlyPreparation Choosing the installation locationMinimum clearances for the outdoor unit Indoor unit Packing and UnpackingOutdoor unit Accessories in the indoor unit package Checking and preparing accessories and tools AccessoriesOptional accessories Drilling a hole through the wall Accessories in the outdoor unit packageTools Taping the pipes, cables, and drain hose Disassembling the cover panel Indoor Unit InstallationDisassembling the installation plate Remove the cap screws, then the screwsConnecting the cables assembly cable Prepare the following tools Optional Extending the power cableCompression dimension should be Apply heat to the contraction tube to contract itInstall the drain hose Installing and connecting the drain hoseIncomplete wire Optional Extending the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe Depth aWhen fixing the indoor unit on a wall 10 Fixing the installation plateWhen fixing the indoor unit on a window frame Fix the installation plate without inclining to one side 11 Fixing the indoor unit to the installation plateWhen fixing the indoor unit on a gypsum board 12 Assembling the cover panelFixing the outdoor unit in place Outdoor Unit InstallationConnecting the cables and the refrigerant pipes Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Leave the system in the standby modeCooling capacity and malfunction. Use a vacuum pump Adding refrigerant SiphonRunning the Smart Install mode Installation InspectionPerforming the gas leak tests Motor Connector Remove foreign substance. Check Error indicatorError Measures for the installer to take Display Blocking error OpenPerforming final check and trial operation Check the following Strength of the installation siteTurn on th air conditioner and select Fast Cool mode Pumping down refrigerant