Samsung AR18MQJSBWKXMG, AR18MRJSBWKXMG manual Energy-Saving Operation, Single user function

Page 20

Energy-Saving Operation

The smart energy-saving functions of the Samsung air conditioner reduce electricity consumption.

Single user function

Use the Single user function to reduce electricity consumption while staying cool. You can select this function in the Cool mode.

In the Cool mode

Select Single user.

NOTE

• When the Single user function starts, the pattern appears on the remote control for a few seconds, and vertical air swing begins automatically.

If you select the Single user while such function as 2-Step cooling, Fast, Comfort, or good'sleep are running, these modes are cancelled.

After selecting the Single user function, you can change the set temperature (24 °C to 30 °C in the Cool mode), fan speed, and vertical air flow direction.

When the Single user function is turned on in the Cool mode while the set temperature is set to lower than 24 °C, the set temperature is automatically raised to 24 °C. But if the set temperature is set to between 25 °C and 30 °C, it remains the same.

Even after you turn off the Single user function, vertical air swing continues until you turn it off with the Vertical air swing ( ) button.

Energy-Saving Features

English 19

Image 20
Contents Questions or COMMENTS? Airconditioner DB68-06070A-01Contents Correct Disposal of This Product This may result in electric shock or fire Safety InformationFailing to do so may result in electric shock or fire For Power Supply Do not touch the circuit breakerwith wet hands This may result in electric shockThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not place objects or devices under the indoor unit Do not operate the appliance with wet handsDo not drink the water from the air conditioner Do not touch the pipes connected with the productFor Cleaning Do not clean the inside of the air conditioner by yourselfOperation indicator Single user indicatorIndoor Unit Overview DisplayRemote Control Overview Inserting batteriesOperation modes Remote Control OperationControlling temperature Controlling fan speed Controlling air flow directionStep cooling function Cool modeCooling Operation Dry mode Dehumidifying OperationHeat mode Heating OperationFan mode Quick Smart FeaturesAuto mode Fast function Comfort function Beep sound functionEnergy-Saving Operation Single user functionTimed on/Timed off function Default operation time for the good’sleep function Good’sleep functionCleaning at a Glance Running Auto cleanCleaning duration minutes Do not clean the display by using alkaline detergentCleaning the filter Troubleshooting Indicator blinks Check whether the drains are clean. Clean them regularlyTo pass the error code to the service centre Does not work24˚C Technical Specifications35˚C Model AR24KRJSRWK/MG AR18MRJSBWK/MG AR18MQJSBWK/MG Model AR24MRJSRWK/MG General information Safety Information on InstallationInstallation of the unit Power supply line, fuse, or circuit breaker Install the unit in a place where water can drain smoothlyMinimum clearances for the outdoor unit Choosing the installation locationPreparation Outdoor unit Packing and UnpackingIndoor unit Optional accessories Checking and preparing accessories and tools AccessoriesAccessories in the indoor unit package Tools Accessories in the outdoor unit packageDrilling a hole through the wall Taping the pipes, cables, and drain hose Indoor Unit Installation Disassembling the installation plateDisassembling the cover panel Remove the cap screws, then the screwsConnecting the cables assembly cable Optional Extending the power cable Compression dimension should bePrepare the following tools Apply heat to the contraction tube to contract itInstalling and connecting the drain hose Incomplete wireInstall the drain hose Optional Extending the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe Depth aWhen fixing the indoor unit on a window frame 10 Fixing the installation plateWhen fixing the indoor unit on a wall 11 Fixing the indoor unit to the installation plate When fixing the indoor unit on a gypsum boardFix the installation plate without inclining to one side 12 Assembling the cover panelOutdoor Unit Installation Connecting the cables and the refrigerant pipesFixing the outdoor unit in place Optional Fixing the outdoor unit to a wall with a rackCooling capacity and malfunction. Use a vacuum pump Leave the system in the standby modeEvacuating the air Adding refrigerant SiphonPerforming the gas leak tests Installation InspectionRunning the Smart Install mode Error indicator Error Measures for the installer to take DisplayMotor Connector Remove foreign substance. Check Blocking error OpenCheck the following Strength of the installation site Turn on th air conditioner and select Fast Cool modePerforming final check and trial operation Pumping down refrigerant