Samsung AR18MQJSBWKXMG, AR18MRJSBWKXMG, AR18MRJSBWKNMG, AR18KQJSBWKNMG manual Model AR24MRJSRWK/MG

Page 30

MODEL

 

AR24MRJSRWK/MG

 

 

 

 

 

 

 

 

 

 

CLIMATES CLASS

 

T1

 

T3

 

 

 

 

 

 

 

 

CAPACITY

COOLING

22000 Btu/h

 

18000 Btu/h

 

 

 

 

 

 

 

 

HEATING (H1)

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED VOLTAGE & FREQUENCY

 

 

230 V ~ 60 Hz

 

RATED CURRENT

COOLING

8.5 A

 

9.5 A

 

 

 

 

 

 

 

 

 

HEATING (H1)

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED POWER

COOLING

1910 W

 

2170 W

 

 

 

 

 

 

 

 

 

INPUT

HEATING (H1)

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

EER/COP

COOLING

11.50 (Btu/hr)/W

8.30 (Btu/hr)/W

 

 

 

 

 

 

 

 

HEATING (H1)

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFRIGERANT

TYPE

 

 

R-410A

 

 

 

 

 

 

 

 

 

CHARGE

 

 

1200 g [42.33 oz]

 

 

 

 

 

 

 

 

 

 

 

 

ANNUAL ENERGY CONSUMPTION

 

 

5157 kWh/Year

 

 

 

 

 

 

 

 

 

 

 

INDOOR

27˚C

 

-

 

29˚C

 

-

 

 

 

 

 

 

 

 

TEMPERATURE

19˚C

 

-

 

19˚C

 

-

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

35˚C

 

-

 

46˚C

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

24˚C

 

-

 

24˚C

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

NET WEIGHT

INDOOR

 

 

14.5 kg

 

 

 

 

 

 

 

 

 

OUTDOOR

 

 

52.5 kg

 

 

 

 

 

 

 

 

 

 

DIMENSIONS OF

INDOOR

 

1065 x 301 x 294 mm

 

 

 

 

 

 

 

 

 

THE UNIT

OUTDOOR

 

880 x 793 x 310 mm

 

 

 

 

 

 

 

 

 

 

COUNTRY OF ORIGIN

 

 

THAILAND

 

 

 

 

 

 

 

 

 

 

Cleaning and Maintenance

English 29

Image 30
Contents Questions or COMMENTS? Airconditioner DB68-06070A-01Contents Correct Disposal of This Product Safety Information Failing to do so may result in electric shock or fireThis may result in electric shock or fire For Power Supply This may result in electric shock or burns Do not touch the circuit breakerwith wet handsThis may result in electric shock This may result in children seriously injuring themselvesDo not drink the water from the air conditioner Do not place objects or devices under the indoor unitDo not operate the appliance with wet hands Do not touch the pipes connected with the productFor Cleaning Do not clean the inside of the air conditioner by yourselfIndoor Unit Overview Operation indicatorSingle user indicator DisplayRemote Control Overview Inserting batteriesRemote Control Operation Controlling temperatureOperation modes Controlling fan speed Controlling air flow directionCool mode Cooling OperationStep cooling function Dry mode Dehumidifying OperationHeat mode Heating OperationQuick Smart Features Auto modeFan mode Fast function Comfort function Beep sound functionEnergy-Saving Operation Single user functionTimed on/Timed off function Default operation time for the good’sleep function Good’sleep functionCleaning duration minutes Cleaning at a GlanceRunning Auto clean Do not clean the display by using alkaline detergentCleaning the filter Troubleshooting To pass the error code to the service centre Indicator blinksCheck whether the drains are clean. Clean them regularly Does not workTechnical Specifications 35˚C24˚C Model AR24KRJSRWK/MG AR18MRJSBWK/MG AR18MQJSBWK/MG Model AR24MRJSRWK/MG Safety Information on Installation Installation of the unitGeneral information Power supply line, fuse, or circuit breaker Install the unit in a place where water can drain smoothlyChoosing the installation location PreparationMinimum clearances for the outdoor unit Packing and Unpacking Indoor unitOutdoor unit Checking and preparing accessories and tools Accessories Accessories in the indoor unit packageOptional accessories Accessories in the outdoor unit package Drilling a hole through the wallTools Taping the pipes, cables, and drain hose Disassembling the cover panel Indoor Unit InstallationDisassembling the installation plate Remove the cap screws, then the screwsConnecting the cables assembly cable Prepare the following tools Optional Extending the power cableCompression dimension should be Apply heat to the contraction tube to contract itInstall the drain hose Installing and connecting the drain hoseIncomplete wire Optional Extending the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe Depth a10 Fixing the installation plate When fixing the indoor unit on a wallWhen fixing the indoor unit on a window frame Fix the installation plate without inclining to one side 11 Fixing the indoor unit to the installation plateWhen fixing the indoor unit on a gypsum board 12 Assembling the cover panelFixing the outdoor unit in place Outdoor Unit InstallationConnecting the cables and the refrigerant pipes Optional Fixing the outdoor unit to a wall with a rackLeave the system in the standby mode Evacuating the airCooling capacity and malfunction. Use a vacuum pump Adding refrigerant SiphonInstallation Inspection Running the Smart Install modePerforming the gas leak tests Motor Connector Remove foreign substance. Check Error indicatorError Measures for the installer to take Display Blocking error OpenPerforming final check and trial operation Check the following Strength of the installation siteTurn on th air conditioner and select Fast Cool mode Pumping down refrigerant