Installation

When fixing the indoor unit on a gypsum board

1Use stud finder to find out locations of the studs.

2Fix the plate hanger on two studs.

CAUTION

If you fix the indoor unit on a gypsum board, use only specified anchor bolts on reference positions. Otherwise, the gypsum surrounding the joints may crumble over time and cause the screws to be loosened and stripped. This may lead to physical injury or equipment damage.

Search for other spots if there are less than two studs, or the distance between the studs are different from the plate hanger.

Fix the installation plate without inclining to one side.

Step 2.11 Fixing the indoor unit to the installation plate

CAUTION

Make sure that the pipe bundle does not move when you install the indoor unit onto the installation plate.

Step 2.12 Assembling the cover panel

1Lock the side hooks (D), then centre hooks (B). Then lock the bottom hooks (C) to engage the cover panel in place.

2Fasten the screw (A-), then assemble the cap screws (A-).

A B

A B

CD C

2

D

1

BB

C C

A

A

1

2

44English

Image 45
Contents Questions or COMMENTS? DB68-06070A-01 AirconditionerContents Correct Disposal of This Product Safety Information Failing to do so may result in electric shock or fireThis may result in electric shock or fire For Power Supply This may result in electric shock Do not touch the circuit breakerwith wet handsThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not operate the appliance with wet hands Do not place objects or devices under the indoor unitDo not drink the water from the air conditioner Do not touch the pipes connected with the productDo not clean the inside of the air conditioner by yourself For CleaningSingle user indicator Operation indicatorIndoor Unit Overview DisplayInserting batteries Remote Control OverviewRemote Control Operation Controlling temperatureOperation modes Controlling air flow direction Controlling fan speedCool mode Cooling OperationStep cooling function Dehumidifying Operation Dry modeHeating Operation Heat modeQuick Smart Features Auto modeFan mode Fast function Beep sound function Comfort functionSingle user function Energy-Saving OperationTimed on/Timed off function Good’sleep function Default operation time for the good’sleep functionRunning Auto clean Cleaning at a GlanceCleaning duration minutes Do not clean the display by using alkaline detergentCleaning the filter Troubleshooting Check whether the drains are clean. Clean them regularly Indicator blinksTo pass the error code to the service centre Does not workTechnical Specifications 35˚C24˚C Model AR24KRJSRWK/MG AR18MRJSBWK/MG AR18MQJSBWK/MG Model AR24MRJSRWK/MG Safety Information on Installation Installation of the unitGeneral information Install the unit in a place where water can drain smoothly Power supply line, fuse, or circuit breakerChoosing the installation location PreparationMinimum clearances for the outdoor unit Packing and Unpacking Indoor unitOutdoor unit Checking and preparing accessories and tools Accessories Accessories in the indoor unit packageOptional accessories Accessories in the outdoor unit package Drilling a hole through the wallTools Taping the pipes, cables, and drain hose Disassembling the installation plate Indoor Unit InstallationDisassembling the cover panel Remove the cap screws, then the screwsConnecting the cables assembly cable Compression dimension should be Optional Extending the power cablePrepare the following tools Apply heat to the contraction tube to contract itIncomplete wire Installing and connecting the drain hoseInstall the drain hose Optional Extending the drain hoseOptional Changing the direction of the drain hose Depth a Shortening or extending the refrigerant pipes assembly pipe10 Fixing the installation plate When fixing the indoor unit on a wallWhen fixing the indoor unit on a window frame When fixing the indoor unit on a gypsum board 11 Fixing the indoor unit to the installation plateFix the installation plate without inclining to one side 12 Assembling the cover panelConnecting the cables and the refrigerant pipes Outdoor Unit InstallationFixing the outdoor unit in place Optional Fixing the outdoor unit to a wall with a rackLeave the system in the standby mode Evacuating the airCooling capacity and malfunction. Use a vacuum pump Siphon Adding refrigerantInstallation Inspection Running the Smart Install modePerforming the gas leak tests Error Measures for the installer to take Display Error indicatorMotor Connector Remove foreign substance. Check Blocking error OpenTurn on th air conditioner and select Fast Cool mode Check the following Strength of the installation sitePerforming final check and trial operation Pumping down refrigerant