Samsung AR24KRJSRWKXMG, AR18MQJSBWKXMG, AR18MRJSBWKXMG manual AR18MRJSBWK/MG AR18MQJSBWK/MG

Page 29

Cleaning and Maintenance

MODEL

 

AR18MRJSBWK/MG

 

 

AR18MQJSBWK/MG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLIMATES CLASS

 

T1

 

T3

 

 

T1

T3

 

 

 

 

 

 

 

 

 

 

 

 

CAPACITY

COOLING

17500 Btu/h

 

15000 Btu/h

17500 Btu/h

15000 Btu/h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING (H1)

 

-

 

 

 

 

 

5000 W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED VOLTAGE & FREQUENCY

 

 

230 V ~ 60 Hz

 

 

 

230 V ~ 60 Hz

 

RATED CURRENT

COOLING

6.6 A

 

7.9 A

 

6.6 A

7.9 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING (H1)

 

-

 

 

 

 

 

6.8 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED POWER

COOLING

1480 W

 

1780 W

1490 W

1770 W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

HEATING (H1)

 

-

 

 

 

 

 

1560 W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EER/COP

COOLING

11.80 (Btu/hr)/W

 

8.45 (Btu/hr)/W

11.72 (Btu/hr)/W

8.45 (Btu/hr)/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEATING (H1)

 

-

 

 

 

 

 

3.20 W/W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFRIGERANT

TYPE

 

 

 

 

 

 

R-410A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHARGE

 

 

950 g [33.51 oz]

 

 

1820 g [64.20 oz]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ANNUAL ENERGY CONSUMPTION

 

 

3996 kWh/Year

 

 

 

4023 kWh/Year

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR

27˚C

 

-

 

29˚C

 

-

27˚C

 

20˚C

29˚C

 

20˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE

19˚C

 

-

 

19˚C

 

-

19˚C

 

15˚C

19˚C

 

15˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

35˚C

 

-

 

46˚C

 

-

35˚C

 

7˚C

46˚C

 

7˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24˚C

 

-

 

24˚C

 

-

24˚C

 

6˚C

24˚C

 

6˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NET WEIGHT

INDOOR

 

 

13.4 kg

 

 

 

13.4 kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

 

 

40.7 kg

 

 

 

51.5 kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS OF

INDOOR

 

1065 x 301 x 294 mm

 

1065 x 301 x 294 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THE UNIT

OUTDOOR

 

880 x 648 x 310 mm

 

 

880 x 793 x 310 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COUNTRY OF ORIGIN

 

 

 

 

 

 

THAILAND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28English

Image 29
Contents Questions or COMMENTS? DB68-06070A-01 AirconditionerContents Correct Disposal of This Product This may result in electric shock or fire Safety InformationFailing to do so may result in electric shock or fire For Power Supply This may result in electric shock Do not touch the circuit breakerwith wet handsThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not operate the appliance with wet hands Do not place objects or devices under the indoor unitDo not drink the water from the air conditioner Do not touch the pipes connected with the productDo not clean the inside of the air conditioner by yourself For CleaningSingle user indicator Operation indicatorIndoor Unit Overview DisplayInserting batteries Remote Control OverviewOperation modes Remote Control OperationControlling temperature Controlling air flow direction Controlling fan speedStep cooling function Cool modeCooling Operation Dehumidifying Operation Dry modeHeating Operation Heat modeFan mode Quick Smart FeaturesAuto mode Fast function Beep sound function Comfort functionSingle user function Energy-Saving OperationTimed on/Timed off function Good’sleep function Default operation time for the good’sleep functionRunning Auto clean Cleaning at a GlanceCleaning duration minutes Do not clean the display by using alkaline detergentCleaning the filter Troubleshooting Check whether the drains are clean. Clean them regularly Indicator blinksTo pass the error code to the service centre Does not work24˚C Technical Specifications35˚C Model AR24KRJSRWK/MG AR18MRJSBWK/MG AR18MQJSBWK/MG Model AR24MRJSRWK/MG General information Safety Information on InstallationInstallation of the unit Install the unit in a place where water can drain smoothly Power supply line, fuse, or circuit breakerMinimum clearances for the outdoor unit Choosing the installation locationPreparation Outdoor unit Packing and UnpackingIndoor unit Optional accessories Checking and preparing accessories and tools AccessoriesAccessories in the indoor unit package Tools Accessories in the outdoor unit packageDrilling a hole through the wall Taping the pipes, cables, and drain hose Disassembling the installation plate Indoor Unit InstallationDisassembling the cover panel Remove the cap screws, then the screwsConnecting the cables assembly cable Compression dimension should be Optional Extending the power cablePrepare the following tools Apply heat to the contraction tube to contract itIncomplete wire Installing and connecting the drain hoseInstall the drain hose Optional Extending the drain hoseOptional Changing the direction of the drain hose Depth a Shortening or extending the refrigerant pipes assembly pipeWhen fixing the indoor unit on a window frame 10 Fixing the installation plateWhen fixing the indoor unit on a wall When fixing the indoor unit on a gypsum board 11 Fixing the indoor unit to the installation plateFix the installation plate without inclining to one side 12 Assembling the cover panelConnecting the cables and the refrigerant pipes Outdoor Unit InstallationFixing the outdoor unit in place Optional Fixing the outdoor unit to a wall with a rackCooling capacity and malfunction. Use a vacuum pump Leave the system in the standby modeEvacuating the air Siphon Adding refrigerantPerforming the gas leak tests Installation InspectionRunning the Smart Install mode Error Measures for the installer to take Display Error indicatorMotor Connector Remove foreign substance. Check Blocking error OpenTurn on th air conditioner and select Fast Cool mode Check the following Strength of the installation sitePerforming final check and trial operation Pumping down refrigerant