mode

For a comfortable sleep, the air conditioner will operate in 3 stages in order of Fall asleep Sound sleep Wake up stage.. When the air conditioner is operating in Cool/Heat (ARJQ) mode;

1.

2.

3.

Press the Timer button to select (

)..

 

-- (

) indicator will keep blinking and you can set the time..

Press the

button to set the time..

 

-- You can set the time in half hour unit from 30 minutes (0..5 on the display) ~

3 hours and hour unit from 3~12 hours..

 

-- Time can be set from minimum 30 minutes to maximum 12 hours..

-- Default time setting for the

mode is 8 hours..

Press the SET button to complete the

mode setting..

-- (

) indicator and the set time of the

mode will be displayed on

the remote controller display..

 

 

-- Timer indicator (

) will be displayed on the indoor unit display..

--

mode setting will be cancelled if you don't press the SET button within

10 seconds after setting the time.. Therefore, check for the ( ) indicator on the

remote controller display and the Timer indicator (

) on the indoor unit display..

Cancel

ffPress the Timer button select ( ) press the

or

button

 

set the timer to

press the SET button..

 

 

Remote controller display

Additional options available inmode

You can adjust the set temperature by 1 °C within the range of 16 °C~30 °C.

Fan speed will be adjusted automatically according to themode.

However, If you selectmode while heating operation is on, you can adjust fan speed.

When themode is on.

In Cool mode: Air flow direction will be adjusted automatically.

In Heat (ARJQ) mode: Adjusting air flow direction is available.

Temperature and fan speed change inmode

•• Fall asleep: Eases you into sleep by dropping the temperature..

•• Sound sleep: Relaxes your body and raises your temperature slightly..

•• Wake up: Allows you to wake up from comfortable intermittent air and it makes you feel refreshed..

• Recommended set temperature is between 25 °C ~ 27 °C for cooling and 21 ˚C~23 ˚C for heating (ARJQ).

• If the set temperature is too low, you may feel cold during sleep or catch a cold..

Optimal operation hour of mode is 8 hours.. Therefore, if the time is set too short or long, you may not feel as comfortable as you would expect..

If the mode is set over 5 hours, Wake up stage will begin when 1 hour is remaining in the operation time and the air conditioner will stop automatically..

When the On timer and the function is set simultaneously, the air conditioner will only apply the function that was set later..

English-20

MG_BETTER_ON&OFF_A3050_IB&IM_DB68-05189A.indd 20

2/17/2015 2:56:02 PM

Image 20
Contents Air Conditioner Features of your new air conditioner Contents Safety precautions English-4English-5 01epPr arationFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9English-10 Checking before useOperation ranges Technical Specifications English-11Checking the name of the parts Main partsDisplay English-12English-13 Checking the remote controllerRemote controller buttons Remote controller display Low Battery warningStoring the remote controller Inserting the batteriesBasic function English-16 Press the button to adjust the temperaturePress the button to set the desired fan speed Adjusting the air flow direction English-17Setting the On/Off timer Setting the On timerFfPress the Timer button select On press the or button  English-18Setting the Off timer English-19Er03mti ButtonEnglish-20 Additional options available in modeMode Step cooling function English-21Press the Options button 04 optioUsing the Fast function Using the Comfort functionEnglish-22 You can set the Comfort function to provide mild coolingUsing the Single user function Single user function is only available in Cool modeCancelled English-23English-24 Using the Virus Doctor functionMake the indicator blink and press the SET button Using the Auto clean function Checking the usage timeEnglish-25 SettiSetting the Beep sound Resetting the Filter clean reminderSetting the Display option English-26Cleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger English-27Cleaning the Air filter Removing the Air filterEnglish-28 Remove the Air filter from the main bodyTop of the Air filter into the main body.. ➀ Reassembling the Air filterEnglish-29 Maintaining the air conditioner English-30Troubleshooting TemperatureAdjustment is not English-31Button or disconnect the power plug/switch Check the Drains have been cleared Regular MaintenanceError is indicated Heard when refrigerant flow movement changes. It is normal07stin llan atio General informationEnglish-33 Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker Indoor unitWhere sulfide gas exists Outdoor UnitEnglish-35 Reduce noise and vibrationWhen installing more than 1 outdoor unit When the air outlet is towards the wallEnglish-36  Figure DescriptionAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case English-37Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsAssembling the hanger screw English-39This QR code for detail video of indoor unit installation Removing the screwsRemoving the Cover panel Before mounting the indoor unit English-40Assembling the Cover panel After mounting the indoor unit English-41Connecting the assembly cable Cable specificationConnecting the cable English-42English-43 Extend the assembly cable if necessaryEach wire is labeled with the corresponding terminal number English-44 Smooth the cut edgesCut off the remaining foam insulation TorqueEvacuating the indoor unit Cutting or extending the pipeEnglish-45 Unscrew the caps at the end of each pipeCracked English-46Correct Inclined Drain hose installation English-47Change the direction only when it is necessary Changing direction of the drain hoseEnglish-48 Check for leakage on both side of the drain outletConnect a drain hose to the drain plug Evacuating the connected pipesEnglish-49 Outer Torque Adding RefrigerantEnglish-50 Cylinder upright Upside down English-51Siphon Charge the refrigerant standing Performing the gas leak tests English-52English-53 Outdoor unit installed on the wall by rackFixing the outdoor unit in place Smart Install mode English-54English-55 Off / Blinking / OnFinal check and trial operation English-56Packing and unpacking guide English-57How to connect your extended power cables English-58Apply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withEnglish-59 Questions or COMMENTS? 021-8255 CE