Samsung AR24JRSDBWKNMG Assembling the Cover panel After mounting the indoor unit, English-41

Page 41

Disassembling/Assembling the Cover panel for indoor unit installation

ffRemoving the hooks on the side

ffRemoving the hooks on the central part

07stin llan atio

 

Caution (fragile)

Caution (fragile)

-- Gently press the both side of the cover

-- Use both hands

panel inwards () and release the

-- Release each hook by pushing it up at an angle..

hooks on both sides()..

 

Assembling the Cover panel (After mounting the indoor unit)

To assemble the Cover panel, proceed in reverse order of disassembling..

Use both hands for assembling and be extra careful not to damage the pipes and drain hose..

Lock the side, center, and bottom hooks in this sequence.. Tighten the bottom panel with the screws, and close the screw holes with their cap..

<Lock the side hook>

<Lock the bottom hook>

<Fasten the screw>

<Assemble the Cap screw>

English-41

MG_BETTER_ON&OFF_A3050_IB&IM_DB68-05189A.indd 41

2/17/2015 2:56:54 PM

Image 41
Contents Air Conditioner Features of your new air conditioner Contents English-4 Safety precautions01epPr aration English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningEnglish-10 Checking before useOperation ranges English-11 Technical SpecificationsMain parts Checking the name of the partsDisplay English-12English-13 Checking the remote controllerRemote controller buttons Low Battery warning Remote controller displayStoring the remote controller Inserting the batteriesBasic function English-16 Press the button to adjust the temperaturePress the button to set the desired fan speed English-17 Adjusting the air flow directionSetting the On timer Setting the On/Off timerFfPress the Timer button select On press the or button  English-18English-19 Setting the Off timerEr03mti ButtonEnglish-20 Additional options available in modeMode English-21 Step cooling functionPress the Options button 04 optioUsing the Comfort function Using the Fast functionEnglish-22 You can set the Comfort function to provide mild coolingSingle user function is only available in Cool mode Using the Single user functionCancelled English-23English-24 Using the Virus Doctor functionMake the indicator blink and press the SET button Checking the usage time Using the Auto clean functionEnglish-25 SettiResetting the Filter clean reminder Setting the Beep soundSetting the Display option English-26Cleaning the indoor unit Cleaning the air conditionerCleaning the outdoor unit heat exchanger English-27Removing the Air filter Cleaning the Air filterEnglish-28 Remove the Air filter from the main bodyTop of the Air filter into the main body.. ➀ Reassembling the Air filterEnglish-29 English-30 Maintaining the air conditionerTemperature TroubleshootingAdjustment is not English-31Check the Drains have been cleared Regular Maintenance Button or disconnect the power plug/switchError is indicated Heard when refrigerant flow movement changes. It is normal07stin llan atio General informationEnglish-33 Installing the unit Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitOutdoor Unit Where sulfide gas existsEnglish-35 Reduce noise and vibrationWhen the air outlet is towards the wall When installing more than 1 outdoor unitEnglish-36  Figure DescriptionAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case English-37 Optional accessories Fixing the installation plate Tools required for installation General Tools Tools for test operationsEnglish-39 Assembling the hanger screwRemoving the screws This QR code for detail video of indoor unit installationRemoving the Cover panel Before mounting the indoor unit English-40English-41 Assembling the Cover panel After mounting the indoor unitCable specification Connecting the assembly cableConnecting the cable English-42English-43 Extend the assembly cable if necessaryEach wire is labeled with the corresponding terminal number Smooth the cut edges English-44Cut off the remaining foam insulation TorqueCutting or extending the pipe Evacuating the indoor unitEnglish-45 Unscrew the caps at the end of each pipeCracked English-46Correct Inclined English-47 Drain hose installationChanging direction of the drain hose Change the direction only when it is necessaryEnglish-48 Check for leakage on both side of the drain outletConnect a drain hose to the drain plug Evacuating the connected pipesEnglish-49 Outer Torque Adding RefrigerantEnglish-50 Cylinder upright Upside down English-51Siphon Charge the refrigerant standing English-52 Performing the gas leak testsEnglish-53 Outdoor unit installed on the wall by rackFixing the outdoor unit in place English-54 Smart Install modeOff / Blinking / On English-55English-56 Final check and trial operationEnglish-57 Packing and unpacking guideEnglish-58 How to connect your extended power cablesApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withEnglish-59 021-8255 CE Questions or COMMENTS?