Samsung AR24JRSDBWKNMG manual Maintaining the air conditioner, English-30

Page 30

Maintaining the air conditioner

If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition.

1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and cut-off the power supply. There may be internal damage if moisture is left in components.

2.Before using the air conditioner again, dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours. This helps remove odors which may have generated from dampness.

Periodical checks

Refer to the following chart to maintain the air conditioner properly.

Type

Description

Every 2

Every 3

Every 4

Once a year

weeks

months

months

 

 

 

 

 

 

 

 

 

 

Clean the Full HD filter (1)

 

 

 

 

 

 

 

 

 

 

Clean the condensate drain pan (2)

 

 

 

 

 

 

 

 

 

Indoor

Thoroughly clean the heat exchanger (2)

 

 

 

unit

Clean the cross fan (2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean the condensate drain pipe (2)

 

 

 

 

 

 

 

 

 

 

Replace the remote controller batteries (1)

 

 

 

 

 

 

 

 

 

 

Clean the heat exchanger on the outside of the unit (2)

 

 

 

 

 

 

 

 

 

 

Clean the heat exchanger on the inside of the unit (2)

 

 

 

 

 

 

 

 

 

 

Clean the electric components with jets of air (2)

 

 

 

Outdoor

 

 

 

 

 

Verify that all the electric components are firmly

 

 

 

unit

tightened (2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean the fan (2)

 

 

 

 

 

 

 

 

 

 

Verify that all the fan assembly is firmly tightened (2)

 

 

 

 

 

 

 

 

 

 

Clean the condensate drain pan (2)

 

 

 

 

 

 

 

 

 

: This check mark requires checking the indoor/outdoor unit periodically. Follow the description to maintain the air conditioner properly.

 

 

 

 

(1)

The described operations should be performed more frequently if

 

 

 

 

 

 

 

the area of installation is very dusty.

 

CAUTION

 

 

 

(2)

These operations must always be performed by qualified personnel.

 

 

 

 

 

 

For more detailed information, see the installation part in the

 

 

 

 

 

manual.

English-30

MG_BETTER_ON&OFF_A3050_IB&IM_DB68-05189A.indd 30

2/17/2015 2:56:36 PM

Image 30
Contents Air Conditioner Features of your new air conditioner Contents Safety precautions English-4English-5 01epPr arationFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9Checking before use Operation rangesEnglish-10 Technical Specifications English-11Display Checking the name of the partsMain parts English-12Checking the remote controller Remote controller buttonsEnglish-13 Storing the remote controller Remote controller displayLow Battery warning Inserting the batteriesBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-16 Adjusting the air flow direction English-17FfPress the Timer button select On press the or button  Setting the On/Off timerSetting the On timer English-18Er03mti Setting the Off timerEnglish-19 ButtonAdditional options available in mode ModeEnglish-20 Press the Options button Step cooling functionEnglish-21 04 optioEnglish-22 Using the Fast functionUsing the Comfort function You can set the Comfort function to provide mild coolingCancelled Using the Single user functionSingle user function is only available in Cool mode English-23Using the Virus Doctor function Make the indicator blink and press the SET buttonEnglish-24 English-25 Using the Auto clean functionChecking the usage time SettiSetting the Display option Setting the Beep soundResetting the Filter clean reminder English-26 Cleaning the outdoor unit heat exchanger Cleaning the air conditioner Cleaning the indoor unit English-27English-28 Cleaning the Air filterRemoving the Air filter Remove the Air filter from the main bodyReassembling the Air filter English-29Top of the Air filter into the main body.. ➀ Maintaining the air conditioner English-30Adjustment is not TroubleshootingTemperature English-31Error is indicated Button or disconnect the power plug/switchCheck the Drains have been cleared Regular Maintenance Heard when refrigerant flow movement changes. It is normalGeneral information English-3307stin llan atio Power supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit Indoor unitEnglish-35 Where sulfide gas existsOutdoor Unit Reduce noise and vibrationEnglish-36 When installing more than 1 outdoor unitWhen the air outlet is towards the wall  Figure DescriptionAccessories in the outdoor unit case AccessoriesAccessories in the indoor unit case English-37Tools required for installation General Tools Fixing the installation plateOptional accessories Tools for test operationsAssembling the hanger screw English-39Removing the Cover panel Before mounting the indoor unit This QR code for detail video of indoor unit installationRemoving the screws English-40Assembling the Cover panel After mounting the indoor unit English-41Connecting the cable Connecting the assembly cableCable specification English-42Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-43 Cut off the remaining foam insulation English-44Smooth the cut edges TorqueEnglish-45 Evacuating the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeEnglish-46 Correct InclinedCracked Drain hose installation English-47English-48 Change the direction only when it is necessaryChanging direction of the drain hose Check for leakage on both side of the drain outletEvacuating the connected pipes English-49Connect a drain hose to the drain plug Adding Refrigerant English-50Outer Torque English-51 Siphon Charge the refrigerant standingCylinder upright Upside down Performing the gas leak tests English-52Outdoor unit installed on the wall by rack Fixing the outdoor unit in placeEnglish-53 Smart Install mode English-54English-55 Off / Blinking / OnFinal check and trial operation English-56Packing and unpacking guide English-57Apply heat to the contraction tube to contract it How to connect your extended power cablesEnglish-58 After tube contraction work is completed, wrap it withEnglish-59 Questions or COMMENTS? 021-8255 CE