Samsung AR24JRSDBWKNMG manual Drain hose installation, English-47

Page 47

Installing and connecting the drain hose of the indoor unit

5cm

 

less

Ditch

Keep a clearance of at least

Do not place the end of the

5 cm between the end of the

drain hose in a hollow.

drain hose and the ground.

 

1) Correct connection

After completing the installation of the drain hose, pour water into the drain pan to check whether the hose is well drained.

2) Incorrect connection

07stin llan atio

Drain hose

 

 

 

 

 

 

 

 

 

 

 

 

 

Pipe

Drain hose

Pipe

• Don’t tie drain hose to the assembly pipe which may lead to water leakage.

• If the diameter of the connection hose is smaller than the product's drain hose, water leakage may occur.

Drain hose installation

1.If necessary, connect the 2 meter extension drain hose to the drain hose.

2.If you use the extension drain hose, insulate the inside of the extension drain hose with a shield.

3.Fit the drain hose into 1 of 2 drain hose holes, then fix the end of the drain hose tightly with a clamp.

• If you do not use the other drain hose hole, block it with a rubber stopper.

4.When extending the Drain Hose, hold the end of Drain Hose and Extended Hose, rotate and insert the drain hose into Extended hose for 40~45 mm. Make sure the two hoses are firmly connected, there is no water leakage.

Drain hose hole

5.Connect the Drain Hose after using Foam Insulation to wrap the Extended Hose. Then, Use vinyl tape to wrap the each side of connection by 20 mm .

 

 

 

40~45 mm

20 mm

20 mm

 

 

 

or more

or more

Drain hose

Extension

 

Extension

 

 

 

drain hose

Drain hose

 

 

 

 

drain hose

Vinyl Tape

Foam Insulation

 

 

 

 

English-47

MG_BETTER_ON&OFF_A3050_IB&IM_DB68-05189A.indd 47

2/17/2015 2:57:01 PM

Image 47
Contents Air Conditioner Features of your new air conditioner Contents English-4 Safety precautions01epPr aration English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningEnglish-10 Checking before useOperation ranges English-11 Technical SpecificationsEnglish-12 Checking the name of the partsMain parts DisplayEnglish-13 Checking the remote controllerRemote controller buttons Inserting the batteries Remote controller displayLow Battery warning Storing the remote controllerBasic function English-16 Press the button to adjust the temperaturePress the button to set the desired fan speed English-17 Adjusting the air flow directionEnglish-18 Setting the On/Off timerSetting the On timer FfPress the Timer button select On press the or button Button Setting the Off timerEnglish-19 Er03mtiEnglish-20 Additional options available in modeMode 04 optio Step cooling functionEnglish-21 Press the Options buttonYou can set the Comfort function to provide mild cooling Using the Fast functionUsing the Comfort function English-22English-23 Using the Single user functionSingle user function is only available in Cool mode CancelledEnglish-24 Using the Virus Doctor functionMake the indicator blink and press the SET button Setti Using the Auto clean functionChecking the usage time English-25English-26 Setting the Beep soundResetting the Filter clean reminder Setting the Display optionEnglish-27 Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerRemove the Air filter from the main body Cleaning the Air filterRemoving the Air filter English-28Top of the Air filter into the main body.. ➀ Reassembling the Air filterEnglish-29 English-30 Maintaining the air conditionerEnglish-31 TroubleshootingTemperature Adjustment is notHeard when refrigerant flow movement changes. It is normal Button or disconnect the power plug/switchCheck the Drains have been cleared Regular Maintenance Error is indicated07stin llan atio General informationEnglish-33 Indoor unit Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerReduce noise and vibration Where sulfide gas existsOutdoor Unit English-35 Figure Description When installing more than 1 outdoor unitWhen the air outlet is towards the wall English-36English-37 AccessoriesAccessories in the indoor unit case Accessories in the outdoor unit caseTools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsEnglish-39 Assembling the hanger screwEnglish-40 This QR code for detail video of indoor unit installationRemoving the screws Removing the Cover panel Before mounting the indoor unitEnglish-41 Assembling the Cover panel After mounting the indoor unitEnglish-42 Connecting the assembly cableCable specification Connecting the cableEnglish-43 Extend the assembly cable if necessaryEach wire is labeled with the corresponding terminal number Torque English-44Smooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe Evacuating the indoor unitCutting or extending the pipe English-45Cracked English-46Correct Inclined English-47 Drain hose installationCheck for leakage on both side of the drain outlet Change the direction only when it is necessaryChanging direction of the drain hose English-48Connect a drain hose to the drain plug Evacuating the connected pipesEnglish-49 Outer Torque Adding RefrigerantEnglish-50 Cylinder upright Upside down English-51Siphon Charge the refrigerant standing English-52 Performing the gas leak testsEnglish-53 Outdoor unit installed on the wall by rackFixing the outdoor unit in place English-54 Smart Install modeOff / Blinking / On English-55English-56 Final check and trial operationEnglish-57 Packing and unpacking guideAfter tube contraction work is completed, wrap it with How to connect your extended power cablesEnglish-58 Apply heat to the contraction tube to contract itEnglish-59 021-8255 CE Questions or COMMENTS?