Samsung AR24JRSDBWKNMG manual Fixing the outdoor unit in place, English-53

Page 53

Fixing the indoor unit in place

Perform the following work on the area where gas leak test was done priory.

After checking for gas leaks in the system, insulate the pipe, hose and cables. Then place the indoor unit on the installation plate.

1.To minimise condensation problems, wrap foam insulation (as shown in the figure) on a part without insulation on the end of the pipes.

2.Wind the pipe, assembly cable and drain hose with vinyl tape.

3.Place the bundle (the pipe, assembly cable and drain hose) in the lower part of the indoor unit carefully so it does not project from the rear of the indoor unit.

4.Hook the indoor unit to the installation plate and move the unit to the right and left until it is securely in place.

• Make sure pipe does not move when you install the indoor unit on an installation plate.

5.Wrap the rest of the pipe with vinyl tape.

6.Attach the pipe to the wall using clamps (optional).

Insulation

Pipes

 

Installation

 

plate

Connecting

Vinyl tape

pipes

Connecting wires

 

Drain hose

 

07stin llan atio

Fixing the outdoor unit in place

Install the outdoor unit in level on a stable base to help avoid the generation of noise and vibration, especially when installing the unit close to a neighbor.

If you install the outdoor unit in a place exposed to strong winds or at a height, fix it to an appropriate support (wall or ground).

1.Place the outdoor unit as indicated on the top of the unit to let the discharged air out properly.

2.Fix the outdoor unit in level to an appropriate support using anchor bolts.

3.If the outdoor unit is exposed to strong winds, install shield plates around the outdoor unit so that the fan can operate correctly.

• Secure the rubber leg to help prevent the generation of noise and vibration.

'X' mm

'Y' mm

 

 

Rubber leg

 

Model

X

Y

18/24JR

660

340

18JQ

 

 

24JQ

645

340

Outdoor unit installed on the wall by rack

Ensure the wall will be able to suspend the weight of rack and outdoor unit;

Install the rack close to the column as much as possible;

Install proper grommet in order to help reduce noise and residual vibration transferred by outdoor unit towards wall.

Designed to cut off residual vibration from outdoor unit to rack.

(not supplied with product)

Soft rubber designed to cut off vibration from rack to wall. (not supplied with product)

English-53

MG_BETTER_ON&OFF_A3050_IB&IM_DB68-05189A.indd 53

2/17/2015 2:57:07 PM

Image 53
Contents Air Conditioner Features of your new air conditioner Contents English-4 Safety precautions01epPr aration English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningEnglish-10 Checking before useOperation ranges English-11 Technical SpecificationsMain parts Checking the name of the partsDisplay English-12English-13 Checking the remote controllerRemote controller buttons Low Battery warning Remote controller displayStoring the remote controller Inserting the batteriesBasic function English-16 Press the button to adjust the temperaturePress the button to set the desired fan speed English-17 Adjusting the air flow directionSetting the On timer Setting the On/Off timerFfPress the Timer button select On press the or button  English-18English-19 Setting the Off timerEr03mti ButtonEnglish-20 Additional options available in modeMode English-21 Step cooling functionPress the Options button 04 optioUsing the Comfort function Using the Fast functionEnglish-22 You can set the Comfort function to provide mild coolingSingle user function is only available in Cool mode Using the Single user functionCancelled English-23English-24 Using the Virus Doctor functionMake the indicator blink and press the SET button Checking the usage time Using the Auto clean functionEnglish-25 SettiResetting the Filter clean reminder Setting the Beep soundSetting the Display option English-26Cleaning the indoor unit Cleaning the air conditionerCleaning the outdoor unit heat exchanger English-27Removing the Air filter Cleaning the Air filterEnglish-28 Remove the Air filter from the main bodyTop of the Air filter into the main body.. ➀ Reassembling the Air filterEnglish-29 English-30 Maintaining the air conditionerTemperature TroubleshootingAdjustment is not English-31Check the Drains have been cleared Regular Maintenance Button or disconnect the power plug/switchError is indicated Heard when refrigerant flow movement changes. It is normal07stin llan atio General informationEnglish-33 Installing the unit Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitOutdoor Unit Where sulfide gas existsEnglish-35 Reduce noise and vibrationWhen the air outlet is towards the wall When installing more than 1 outdoor unitEnglish-36  Figure DescriptionAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case English-37Optional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsEnglish-39 Assembling the hanger screwRemoving the screws This QR code for detail video of indoor unit installationRemoving the Cover panel Before mounting the indoor unit English-40English-41 Assembling the Cover panel After mounting the indoor unitCable specification Connecting the assembly cableConnecting the cable English-42English-43 Extend the assembly cable if necessaryEach wire is labeled with the corresponding terminal number Smooth the cut edges English-44Cut off the remaining foam insulation TorqueCutting or extending the pipe Evacuating the indoor unitEnglish-45 Unscrew the caps at the end of each pipeCracked English-46Correct Inclined English-47 Drain hose installationChanging direction of the drain hose Change the direction only when it is necessaryEnglish-48 Check for leakage on both side of the drain outletConnect a drain hose to the drain plug Evacuating the connected pipesEnglish-49 Outer Torque Adding Refrigerant English-50 Cylinder upright Upside down English-51Siphon Charge the refrigerant standing English-52 Performing the gas leak testsEnglish-53 Outdoor unit installed on the wall by rackFixing the outdoor unit in place English-54 Smart Install modeOff / Blinking / On English-55English-56 Final check and trial operationEnglish-57 Packing and unpacking guideEnglish-58 How to connect your extended power cablesApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withEnglish-59 021-8255 CE Questions or COMMENTS?