Samsung AR24JRSDBWKNMG Checking the usage time, Using the Auto clean function, English-25, Setti

Page 25

Checking the usage time

This function will displayed the accumulated operation time from the moment the air conditioner was turned on to the point when the usage function has been selected.

When the air conditioner is operating;

s ng

1.

2.

3.

Indoor unit display

Press the Settings button..

Press the ,or Setting button until (Usage) indicator starts to blink.. Press the SET button to check the usage time..

-- 3 seconds after setting usage time checking function, (Usage) indicator on the remote controller will disappear..

-- Usage time will be displayed in hour. 0.1 equals to 6 minutes.

Ex) 0..1 6 minutes of usage, 2..5 2 hours and 30 minutes of usage, 3..7 3 hours and 42 minutes of usage..

-- Usage time will be displayed for certain period of time and it will automatically changed to indoor temperature.

-- Usage time will begin to accumulate when the air conditioner turns on, and accumulated usage time will be reset when it turns off.

-- Initial value of usage time is 0..0 and maximum value is 99.. (Unit: hour)

• When the air conditioner is not operating, usage time will not be displayed on the indoor unit display.

05 setti

Using the Auto clean function

Auto clean function will minimise the moisture inside of the indoor unit. Activate this function to help provide you with clean air.

When the air conditioner is operating;

Indoor unit display

1.Press the Settings button..

2.Press the ,or Setting button until (Clean) indicator starts to blink..

3.Press the SET button to set the Auto clean function..

-- 3 seconds after setting Auto clean function, (Clean) indicator on the remote

controller display will disappear and Auto clean ( ), Timer () indicator will turn on the indoor unit display.. Auto clean function will be activated after the air conditioner stops operating..

-- Duration of the Auto clean function can be different depending on the previous operation mode used.

Auto(cool), Cool, Dry mode : 30 minutes.

Auto(heat (ARJQ)), Heat (ARJQ), Fan mode : 15 minutes.

Cancel

ffPress the Setting button Press the

,

or Setting button to

 

make the (Clean) indicator blink and press the SET button..

• When the operation mode is set during Auto clean function is activated, the air conditioner will operate in chosen operation mode and the Auto clean function will be re-activated when the operation stops.

During the auto clean function, indoor fan will continue to run and air flow blade will remain open to expel ambient air.

lighting in Auto clean mode.

English-25

MG_BETTER_ON&OFF_A3050_IB&IM_DB68-05189A.indd 25

2/17/2015 2:56:28 PM

Image 25
Contents Air Conditioner Features of your new air conditioner Contents English-4 Safety precautions01epPr aration English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningOperation ranges Checking before useEnglish-10 English-11 Technical SpecificationsMain parts Checking the name of the partsDisplay English-12Remote controller buttons Checking the remote controllerEnglish-13 Low Battery warning Remote controller displayStoring the remote controller Inserting the batteriesBasic function Press the button to set the desired fan speed Press the button to adjust the temperatureEnglish-16 English-17 Adjusting the air flow directionSetting the On timer Setting the On/Off timerFfPress the Timer button select On press the or button  English-18English-19 Setting the Off timerEr03mti ButtonMode Additional options available in modeEnglish-20 English-21 Step cooling functionPress the Options button 04 optio Using the Comfort function Using the Fast function English-22 You can set the Comfort function to provide mild coolingSingle user function is only available in Cool mode Using the Single user functionCancelled English-23Make the indicator blink and press the SET button Using the Virus Doctor functionEnglish-24 Checking the usage time Using the Auto clean functionEnglish-25 SettiResetting the Filter clean reminder Setting the Beep soundSetting the Display option English-26Cleaning the indoor unit Cleaning the air conditionerCleaning the outdoor unit heat exchanger English-27Removing the Air filter Cleaning the Air filterEnglish-28 Remove the Air filter from the main bodyEnglish-29 Reassembling the Air filterTop of the Air filter into the main body.. ➀ English-30 Maintaining the air conditionerTemperature TroubleshootingAdjustment is not English-31Check the Drains have been cleared Regular Maintenance Button or disconnect the power plug/switchError is indicated Heard when refrigerant flow movement changes. It is normalEnglish-33 General information07stin llan atio Installing the unit Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitOutdoor Unit Where sulfide gas existsEnglish-35 Reduce noise and vibrationWhen the air outlet is towards the wall When installing more than 1 outdoor unitEnglish-36  Figure DescriptionAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case English-37Optional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsEnglish-39 Assembling the hanger screwRemoving the screws This QR code for detail video of indoor unit installationRemoving the Cover panel Before mounting the indoor unit English-40English-41 Assembling the Cover panel After mounting the indoor unitCable specification Connecting the assembly cableConnecting the cable English-42Each wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryEnglish-43 Smooth the cut edges English-44Cut off the remaining foam insulation TorqueCutting or extending the pipe Evacuating the indoor unitEnglish-45 Unscrew the caps at the end of each pipeCorrect Inclined English-46Cracked English-47 Drain hose installationChanging direction of the drain hose Change the direction only when it is necessaryEnglish-48 Check for leakage on both side of the drain outletEnglish-49 Evacuating the connected pipesConnect a drain hose to the drain plug English-50 Adding RefrigerantOuter Torque Siphon Charge the refrigerant standing English-51Cylinder upright Upside down English-52 Performing the gas leak testsFixing the outdoor unit in place Outdoor unit installed on the wall by rackEnglish-53 English-54 Smart Install modeOff / Blinking / On English-55English-56 Final check and trial operationEnglish-57 Packing and unpacking guideEnglish-58 How to connect your extended power cablesApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withEnglish-59 021-8255 CE Questions or COMMENTS?