Samsung AR24JRSDBWKNMG manual Fixing the installation plate, Optional accessories, English-38

Page 38

• The flare nuts are attached to the end of each pipe of an evaporator or a service port.

Use the nuts when connecting the pipes.

The wire assembly cable is optional. If it is not supplied, use the standard cable.

The drain plug and rubber leg are only included when the air conditioner is supplied without the assembly pipe as seen in the picture below.

Optional accessories

The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air conditioner.

Insulated Assembly Pipe,

Insulated Assembly Pipe,

Insulated Assembly Pipe,

PE T3 Foam Tube

Vinyl Tapes (2)

Drain Hose,

Ø6.35 mm x 5 m (1) ✴✴18✴✴

Ø12.70 mm x 5 m (1)

Ø15.88 mm x 4 m (1)

Insulation (1)

length 2 m (1)

Ø6.35 mm x 4 m (1) ✴✴24✴✴

✴✴18✴✴

✴✴24✴✴

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Putty 100 g (1)

Pipe Clamps A (3)

Pipe Clamps B (3)

Cement Nails (6)

M4 x 25 Tapped

Screws (6)

4-wire

Assembly Cable (1)

✴✴18/24✴✴

• If these accessories are supplied, they will be in the accessory box.

Tools required for installation

General Tools

• Vacuum Pump(Backward flowing prevention)

• Manifold Gauge

• Stud Finder

• Torque Wrench

• Pipe Cutter

• Reamer

• Pipe Bender

• Spirit Level

• Screw Driver

• Spanner

• Drill

• L Wrench

• Measuring Tape

Tools for test operations

• Thermometer

• Resistance Meter

• Electroscope

Fixing the installation plate

You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65 mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.

When facing the wall, the pipe and cable can be connected from the:

• Right (A)

Direction of pipe

 

 

 

• Left (B)

 

 

• Underside_right (C)

A

B

• Rear_right or left (D)

D

D

 

C

 

You can install the refrigerant pipe in the left/right/bottom, or the rear side of the indoor unit.

• If changing the pipe direction from left to right, do not drastically bent it but slowly turn it in the opposite direction as shown. Otherwise, the pipe may be damaged in the process.

English-38

MG_BETTER_ON&OFF_A3050_IB&IM_DB68-05189A.indd 38

2/17/2015 2:56:45 PM

Image 38
Contents Air Conditioner Features of your new air conditioner Contents Safety precautions English-4English-5 01epPr arationFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9English-10 Checking before useOperation ranges Technical Specifications English-11Display Checking the name of the partsMain parts English-12English-13 Checking the remote controllerRemote controller buttons Storing the remote controller Remote controller displayLow Battery warning Inserting the batteriesBasic function English-16 Press the button to adjust the temperaturePress the button to set the desired fan speed Adjusting the air flow direction English-17FfPress the Timer button select On press the or button  Setting the On/Off timerSetting the On timer English-18Er03mti Setting the Off timerEnglish-19 ButtonEnglish-20 Additional options available in modeMode Press the Options button Step cooling functionEnglish-21 04 optioEnglish-22 Using the Fast functionUsing the Comfort function You can set the Comfort function to provide mild coolingCancelled Using the Single user functionSingle user function is only available in Cool mode English-23English-24 Using the Virus Doctor functionMake the indicator blink and press the SET button English-25 Using the Auto clean functionChecking the usage time SettiSetting the Display option Setting the Beep soundResetting the Filter clean reminder English-26Cleaning the outdoor unit heat exchanger Cleaning the air conditionerCleaning the indoor unit English-27English-28 Cleaning the Air filterRemoving the Air filter Remove the Air filter from the main bodyTop of the Air filter into the main body.. ➀ Reassembling the Air filterEnglish-29 Maintaining the air conditioner English-30Adjustment is not TroubleshootingTemperature English-31Error is indicated Button or disconnect the power plug/switchCheck the Drains have been cleared Regular Maintenance Heard when refrigerant flow movement changes. It is normal07stin llan atio General informationEnglish-33 Power supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit Indoor unitEnglish-35 Where sulfide gas existsOutdoor Unit Reduce noise and vibrationEnglish-36 When installing more than 1 outdoor unitWhen the air outlet is towards the wall  Figure DescriptionAccessories in the outdoor unit case AccessoriesAccessories in the indoor unit case English-37Tools required for installation General Tools Fixing the installation plateOptional accessories Tools for test operationsAssembling the hanger screw English-39Removing the Cover panel Before mounting the indoor unit This QR code for detail video of indoor unit installationRemoving the screws English-40Assembling the Cover panel After mounting the indoor unit English-41Connecting the cable Connecting the assembly cableCable specification English-42English-43 Extend the assembly cable if necessaryEach wire is labeled with the corresponding terminal number Cut off the remaining foam insulation English-44Smooth the cut edges TorqueEnglish-45 Evacuating the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeCracked English-46Correct Inclined Drain hose installation English-47English-48 Change the direction only when it is necessaryChanging direction of the drain hose Check for leakage on both side of the drain outletConnect a drain hose to the drain plug Evacuating the connected pipesEnglish-49 Outer Torque Adding RefrigerantEnglish-50 Cylinder upright Upside down English-51Siphon Charge the refrigerant standing Performing the gas leak tests English-52English-53 Outdoor unit installed on the wall by rackFixing the outdoor unit in place Smart Install mode English-54English-55 Off / Blinking / OnFinal check and trial operation English-56Packing and unpacking guide English-57Apply heat to the contraction tube to contract it How to connect your extended power cablesEnglish-58 After tube contraction work is completed, wrap it withEnglish-59 Questions or COMMENTS? 021-8255 CE