Troubleshooting
Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses.
PROBLEM | SOLUTION |
|
|
The air conditioner | • Check power status and then operate the air conditioner again. | ||
does not work at all. | • Plug in or switch on the circuit breaker and then operate the air | ||
| conditioner again. |
|
|
| • Ensure Isolator is switch on. |
|
|
| • Check if you have set the Off Timer. Operate the air conditioner | ||
| again by pressing the Power button. |
| |
The temperature | • Check if you have selected Fan/Fast mode. In these modes, desired | ||
adjustment is not | temperature is set to auto and you cannot adjust the temperature. | ||
working. |
|
|
|
|
| ||
Cool/Warm air does | • Check if the set temperature is higher(during Cool mode)/ | ||
not come out of the | lower(during Heat mode (ARJQ)) than the current | ||
air conditioner. | temperature. Press the Temp + or - button on the remote controller | ||
| to change the set temperature. |
|
|
| • Check if the Air filter is blocked by dirt. If there is a lot of dust on the | ||
| Air filter, cooling(heating(ARJQ)) performance may decrease. | ||
| Clean them frequently. |
|
|
| • Check if the outdoor unit is covered or installed near the obstacle. | ||
| Take the cover off and take the | obstacle away. |
|
| • Check if the air conditioner is operating in Defrost mode. When | ||
| the ice formed in winter or the outdoor temperature is too low, | ||
| the air conditioner operates in Defrost mode automatically. In | ||
| Defrost mode, indoor fan stops and warm air does not come out | ||
| (ARJQ). |
|
|
| • If the doors or windows are open, it may cause bad cooling (heating | ||
| (ARJQ)) performance. |
|
|
| Close the doors and windows. |
|
|
| • Check if the air conditioner has just been turned on after stopping | ||
| cooling or heating (ARJQ) operation. In this case, just a fan will | ||
| run to protect the outdoor unit compressor. |
| |
| • Check if the pipe length is too long. When the pipe length exceeds | ||
| maximum allowable pipe length, cooling (heating (ARJQ)) | ||
| performance may decrease. |
|
|
Air flow adjustment | • Check if you have selected | mode. In this mode, you | |
is not working. | cannot adjust the air flow direction. (If the | mode | |
| is operating in Heat mode, you can adjust the air flow direction | ||
| (ARJQ).) |
|
|
|
|
|
|