Installing and connecting the drain hose of the indoor unit

6.

Pass the drain hose under the refrigerant pipe, keeping the drain hose tight.

Shield

7.

Pass the drain hose through the hole in the wall. Check if it slants

 

downwards as seen in the picture.

 

 

 

8. Using natural drainage method, check the drainage is normal.

Drain hose

Extension drain hose

• The hose will be fixed permanently into position after finishing the installation and the gas leak test;

refer to page 53 for further details.

• Make sure the installed direction of the drain hose is correct. Inadequate installation may cause condensate water leakage.

• If the drain hose is routed inside the room, insulate the hose so that dripping condensation does not damage the furniture or floors.

DO NOT WALL UP THE DRAIN HOSE CONNECTION !

Drain hose connection must be easy accessible and serviceable.

Changing direction of the drain hose

Change the direction only when it is necessary.

1.Detach the rubber cap with the pliers.

2.Detach the drain hose by pulling it and turning to the right.

3. Insert the drain hose by fixing it with the screw into the groove of the drain hose and the outlet of the drain pan.

Screw hole

Screw

Drain hose

4. Attach the rubber cap with a screwdriver by turning it to the left until it fixes to the end of the groove.

Drain pan outlet

Rubber cap

5. Check for leakage on both side of the drain outlet.

Pour the water in direction of arrow.

Direction of the drained water

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Make sure the indoor unit is in upright position when you pour water to check for leakage. Make sure that the water does not overflow onto the electrical part.

English-48

MG_BETTER_ON&OFF_A3050_IB&IM_DB68-05189A.indd 48

2/17/2015 2:57:04 PM

Image 48
Contents Air Conditioner Features of your new air conditioner Contents Safety precautions English-4English-5 01epPr arationFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9Checking before use Operation rangesEnglish-10 Technical Specifications English-11Checking the name of the parts Main partsDisplay English-12Checking the remote controller Remote controller buttonsEnglish-13 Remote controller display Low Battery warningStoring the remote controller Inserting the batteriesBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-16 Adjusting the air flow direction English-17Setting the On/Off timer Setting the On timerFfPress the Timer button select On press the or button  English-18Setting the Off timer English-19Er03mti ButtonAdditional options available in mode ModeEnglish-20 Step cooling function English-21Press the Options button 04 optioUsing the Fast function Using the Comfort functionEnglish-22 You can set the Comfort function to provide mild coolingUsing the Single user function Single user function is only available in Cool modeCancelled English-23Using the Virus Doctor function Make the indicator blink and press the SET buttonEnglish-24 Using the Auto clean function Checking the usage timeEnglish-25 SettiSetting the Beep sound Resetting the Filter clean reminderSetting the Display option English-26Cleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger English-27Cleaning the Air filter Removing the Air filterEnglish-28 Remove the Air filter from the main bodyReassembling the Air filter English-29Top of the Air filter into the main body.. ➀ Maintaining the air conditioner English-30Troubleshooting TemperatureAdjustment is not English-31Button or disconnect the power plug/switch Check the Drains have been cleared Regular MaintenanceError is indicated Heard when refrigerant flow movement changes. It is normalGeneral information English-3307stin llan atio Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker Indoor unitWhere sulfide gas exists Outdoor UnitEnglish-35 Reduce noise and vibrationWhen installing more than 1 outdoor unit When the air outlet is towards the wallEnglish-36  Figure DescriptionAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case English-37Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsAssembling the hanger screw English-39This QR code for detail video of indoor unit installation Removing the screwsRemoving the Cover panel Before mounting the indoor unit English-40Assembling the Cover panel After mounting the indoor unit English-41Connecting the assembly cable Cable specificationConnecting the cable English-42Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-43 English-44 Smooth the cut edgesCut off the remaining foam insulation Torque Evacuating the indoor unit Cutting or extending the pipe English-45 Unscrew the caps at the end of each pipeEnglish-46 Correct InclinedCracked Drain hose installation English-47Change the direction only when it is necessary Changing direction of the drain hoseEnglish-48 Check for leakage on both side of the drain outletEvacuating the connected pipes English-49Connect a drain hose to the drain plug Adding Refrigerant English-50Outer Torque English-51 Siphon Charge the refrigerant standingCylinder upright Upside down Performing the gas leak tests English-52Outdoor unit installed on the wall by rack Fixing the outdoor unit in placeEnglish-53 Smart Install mode English-54English-55 Off / Blinking / OnFinal check and trial operation English-56Packing and unpacking guide English-57How to connect your extended power cables English-58Apply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withEnglish-59 Questions or COMMENTS? 021-8255 CE