Samsung AR24JRSDBWKNMG manual English-43, Extend the assembly cable if necessary

Page 43

Connecting the assembly cable

1. Extend the assembly cable if necessary.

• Do not connect two or more different cables to extend the length. It may cause fire.

2 . Open the cover panel.

3 . Remove the screw securing the connector cover.

4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals. (Refer to the picture below)

• Each wire is labeled with the corresponding terminal number.

5 . Pass the other end of the cable through the 65 mm hole in the wall.

6 . Close the connector cover by tightening the screw carefully.

7 . Close the cover panel.

8 . Remove the terminal board cover on the side of the outdoor unit. 9. Connect the cables to the terminals as seen in the picture.

Indoor unit

Indoor unit

Outdoor unit

Outdoor unit

• Also circular terminal must be matched with screw size in terminal block.

• After connecting the cables, make sure terminal numbers on the indoor/outdoor unit matches.

Please ensure that Power & Communication cables are separated, they must not be in the same cable.

10.Connect the grounding conductor to the grounding terminals.

11.Close the terminal board cover by tightening the screw carefully.

Connect the wires firmly so that wires can not be pulled out easily.

(If they are loose, it could cause burn-out of the wires.)

Connect the wires according to color codes, referring to the wiring diagram.

The power cable and the interconnection cable should be selected according to the specification in page 42.

English-43

07stin llan atio

MG_BETTER_ON&OFF_A3050_IB&IM_DB68-05189A.indd 43

2/17/2015 2:56:56 PM

Image 43
Contents Air Conditioner Features of your new air conditioner Contents English-4 Safety precautions01epPr aration English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningOperation ranges Checking before useEnglish-10 English-11 Technical SpecificationsEnglish-12 Checking the name of the partsMain parts DisplayRemote controller buttons Checking the remote controllerEnglish-13 Inserting the batteries Remote controller displayLow Battery warning Storing the remote controllerBasic function Press the button to set the desired fan speed Press the button to adjust the temperatureEnglish-16 English-17 Adjusting the air flow directionEnglish-18 Setting the On/Off timerSetting the On timer FfPress the Timer button select On press the or button Button Setting the Off timerEnglish-19 Er03mtiMode Additional options available in modeEnglish-20 04 optio Step cooling functionEnglish-21 Press the Options buttonYou can set the Comfort function to provide mild cooling Using the Fast functionUsing the Comfort function English-22English-23 Using the Single user functionSingle user function is only available in Cool mode CancelledMake the indicator blink and press the SET button Using the Virus Doctor functionEnglish-24 Setti Using the Auto clean functionChecking the usage time English-25English-26 Setting the Beep soundResetting the Filter clean reminder Setting the Display optionEnglish-27 Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerRemove the Air filter from the main body Cleaning the Air filterRemoving the Air filter English-28English-29 Reassembling the Air filterTop of the Air filter into the main body.. ➀ English-30 Maintaining the air conditionerEnglish-31 TroubleshootingTemperature Adjustment is notHeard when refrigerant flow movement changes. It is normal Button or disconnect the power plug/switchCheck the Drains have been cleared Regular Maintenance Error is indicatedEnglish-33 General information07stin llan atio Indoor unit Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerReduce noise and vibration Where sulfide gas existsOutdoor Unit English-35 Figure Description When installing more than 1 outdoor unitWhen the air outlet is towards the wall English-36English-37 AccessoriesAccessories in the indoor unit case Accessories in the outdoor unit caseTools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsEnglish-39 Assembling the hanger screwEnglish-40 This QR code for detail video of indoor unit installationRemoving the screws Removing the Cover panel Before mounting the indoor unitEnglish-41 Assembling the Cover panel After mounting the indoor unitEnglish-42 Connecting the assembly cableCable specification Connecting the cableEach wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryEnglish-43 Torque English-44Smooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe Evacuating the indoor unitCutting or extending the pipe English-45Correct Inclined English-46Cracked English-47 Drain hose installationCheck for leakage on both side of the drain outlet Change the direction only when it is necessaryChanging direction of the drain hose English-48English-49 Evacuating the connected pipesConnect a drain hose to the drain plug English-50 Adding RefrigerantOuter Torque Siphon Charge the refrigerant standing English-51Cylinder upright Upside down English-52 Performing the gas leak testsFixing the outdoor unit in place Outdoor unit installed on the wall by rackEnglish-53 English-54 Smart Install modeOff / Blinking / On English-55English-56 Final check and trial operationEnglish-57 Packing and unpacking guideAfter tube contraction work is completed, wrap it with How to connect your extended power cablesEnglish-58 Apply heat to the contraction tube to contract itEnglish-59 021-8255 CE Questions or COMMENTS?