Samsung AP55Q1CNUMG manual Temperature and Humidity Ranges, If the air conditioner is used at Then

Page 17

Temperature and Humidity Ranges

The following table indicates the temperature and humidity ranges, within which the air conditioner can be used.

If the air conditioner is used at...

Then...

 

 

High temperature

The automatic protection feature may be triggered and the air

 

conditioner stopped.

 

 

Low temperature

A water leakage or some other

 

malfunction may happen if the heat exchanger freezes.

 

 

High humidity levels

Water may condense on and drip from the surface of the

 

indoor unit if it is used for a long periods.

 

 

 

 

Mode

Outdoor Temperature

Indoor Temperature

Indoor Humidity

 

 

 

 

Heating

0°C to 24°C approx.

27°C or less.

-

 

 

 

 

Cooling

21°C to 54°C approx.

18°C to 32°C approx.

80% or less

 

 

 

 

Drying

18°C to 54°C approx.

18°C to 32°C approx.

-

gIf the outdoor temperature is as low as 0°C, the heating capacity drops up to 70~80% depending on the operation condition.

If the cooling operation is used at over 33°C(indoor temperature), it does not cool at its full capacity.

AP50Q1C_IBIM_E 32202-2.indd 17

E-17

2010-07-14 오후 4:42:12

Image 17
Contents Air Conditioner Safety Precautions Contents Indoor Unit View of the UnitInserting the Remote Control Batteries Remote Control-ButtonsFor Operating PreparationCooling Your Room Select the fan speed by pressing Heating Your RoomSelecting the Automatic Operating Mode Changing the Room Temperature Quickly Operating to the Long Distance To adjust the temperature, pressRemoving Excess Humidity Airing Your Room When Adjusting the Air Flow Direction VerticallyAdjusting the Air Flow Direction Horizontally Setting the Off Timer To Cancel the Off TimerTopic Recommendation Other FunctionOperating Recommendations If the air conditioner is used at Then Temperature and Humidity RangesCleaning Your Air Conditioner Problem Explanation/Solution Solving Common ProblemsPower Supply Technical SpecificationsPart Name Accessory Parts ListDrain plug Cable tie Putty Piping Pipe band Cover hole ScrewOutdoor Unit Selection of Installation PlaceIndoor Unit Electrical Work AP50Q1C Series When using NFB No Fuse BreakerWhen using ELB Earth Leakage Circuit Breaker AP55Q1C/AP55Q1D Series When connecting 3Phase 3wires 220V ACInstallation Procedures Flare Processing Connection of Refrigerant PipingPipe Bending Tightening of Connection PartsDrain Hose Connecting the PipeDrilling a Hole in the Wall Air Purge Refrigerant Charging Check Check and Test OperationTest Operation Packing and Unpacking Guide Outdoor unit Wire tube power cable Connection sleeve How to connect your extended power cablesQuestions or COMMENTS?