Selection of Installation Place

 

Indoor Unit

Top view

Install the unit at a place close to the wall facing the outside as it is necessary

 

 

to perform piping connection with the outdoor unit.

 

 

- It is effective to install the unit at a window side to ensure uniform

 

 

distribution of indoor temperature.

Above 50cm

Install the unit at a place where there is no obstacle against the wind around

 

 

the air inlet and air outlet.

 

Install the unit horizontally at a stable, rigid place.

 

(When installing the unit at a place subjected to oscillation, noise may occur.)

Side view

Avoid a place near the door which is frequented by people.

Above

 

 

 

 

 

Avoid a place subject to direct sunlight.

20cm

 

 

 

Outdoor Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not install the outdoor unit on a wood palette.

 

 

 

 

 

 

 

 

Fix the outdoor unit completely to the base surface with anchor bolts.

 

 

 

 

 

 

 

 

The manufacturer is not responsible for the damage occurred by not

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

keeping standard of the installation.

 

 

 

 

 

 

 

Above 100cm

 

 

A place free from the risk of combustible gas leakage.

A place which can bear the weight of the unit.

A place which can bear the fixing strength of the outdoor unit.

Avoid a place subject to oil (including machine oil).

Avoid a saline place.

Avoid a place subject to sulfide gas (hot spring zone).

(When installing the unit at such special environmental conditions, it may cause machine trouble. When it is unavoidable to use such places, It requires special maintenance.)

A place where the discharge air and noise of the outdoor unit do not disturb the neighborhood. (Take special care not to cause any inconvenience to your neighbors when installing the unit on the borderline with your neighborhood.)

A place where strong wind does not head against the air outlet of the outdoor unit. (If a strong wind heads directly against the air outlet at the time of cooling operation, a safety device can be operated.)

Do not install the outdoor unit at an unstable place such as outer wall of an apartment or building. The outdoor unit may fall down, causing severe personal or property damage or loss.

If there is any unavoidable reason to install the unit at such a place, take the following measures against the wind;

1. When installing the unit at a roadside concentrated with buildings,

Wall

install it parallel with the road.

 

2.Install the unit so that the air outlet faces toward the wall at a place such as rooftop, which may be subjected to strong wind.

The outdoor unit should be installed in accordance with the service space.

Air outlet

Strong wind

Roof top

Above 60cm

Above 50cm

Space for piping

and wiring

Above 30cm

The air inlet faces toward the wall.

E-22

Above 50cm

Space for piping and wiring

 

 

Above 60cm

Above 30cm

The air outlet faces towards the wall.

AP50Q1C_IBIM_E 32202-2.indd 22

2010-07-14 오후 4:42:14

Image 22
Contents Air Conditioner Safety Precautions Contents View of the Unit Indoor UnitRemote Control-Buttons Inserting the Remote Control BatteriesOperating Preparation ForCooling Your Room Heating Your Room Select the fan speed by pressingSelecting the Automatic Operating Mode Changing the Room Temperature Quickly To adjust the temperature, press Operating to the Long DistanceRemoving Excess Humidity Airing Your Room Adjusting the Air Flow Direction Horizontally Adjusting the Air Flow Direction VerticallyWhen To Cancel the Off Timer Setting the Off TimerOperating Recommendations Other FunctionTopic Recommendation Temperature and Humidity Ranges If the air conditioner is used at ThenCleaning Your Air Conditioner Solving Common Problems Problem Explanation/SolutionTechnical Specifications Power SupplyDrain plug Cable tie Putty Piping Pipe band Accessory Parts ListPart Name Cover hole ScrewIndoor Unit Selection of Installation PlaceOutdoor Unit Electrical Work When using ELB Earth Leakage Circuit Breaker When using NFB No Fuse BreakerAP50Q1C Series When connecting 3Phase 3wires 220V AC AP55Q1C/AP55Q1D SeriesInstallation Procedures Pipe Bending Connection of Refrigerant PipingFlare Processing Tightening of Connection PartsDrilling a Hole in the Wall Connecting the PipeDrain Hose Air Purge Refrigerant Charging Check and Test Operation CheckTest Operation Packing and Unpacking Guide Outdoor unit How to connect your extended power cables Wire tube power cable Connection sleeveQuestions or COMMENTS?