Samsung AP55Q1DNUMG, AP55Q1CNUMG Drilling a Hole in the Wall, Drain Hose, Connecting the Pipe

Page 28

Drilling a Hole in the Wall

Drill a hole of 70mm in diameter to the outside.

The drilling should be done at a distance of less than 150mm from the floor facing the indoor unit.

ø70mm

Less than

150mm

Drain Hose

Extend the drain hose to the drain hose connected to the drain pan, and fix it with the tape or a cable-tie to prevent separation. Then make a covering of it so that water cannot flow outwardly.

Piping Material

Vinyl Chloride

(Outer diameter ø16mm)

 

 

 

Insulator

Foamed Polyethylene

 

 

Drain pan

Insulation

Band

Drain hose Indoor and outdoor unit connection

1.As the draining is of natural drain type, make the drain hose direct downward.

2.If there is any foreign substance in the drain plate, it may clog the drain pipe. Therefore, be sure to remove the foreign substance inside after installation.

3.After completion of installation, be sure to pour water into the drain pan, and then check the draining condition.(There is no problem in draining when the draining is completed within 20 seconds.)

Connecting the Pipe

The piping of this unit can be connected to the right, left, and rear side.

When you hit the area for piping connection slightly with a hammer, a hole is made.

After connecting the piping and drain hose, insert the rubber cap as shown in the figure.

Holes for piping connection (2 points)

Cover hole

E-28The shape of hole may vary with the models.

AP50Q1C_IBIM_E 32202-2.indd 28

2010-07-14 오후 4:42:16

Image 28
Contents Air Conditioner Safety Precautions Contents View of the Unit Indoor UnitRemote Control-Buttons Inserting the Remote Control BatteriesOperating Preparation ForCooling Your Room Heating Your Room Select the fan speed by pressingSelecting the Automatic Operating Mode Changing the Room Temperature Quickly To adjust the temperature, press Operating to the Long DistanceRemoving Excess Humidity Airing Your Room Adjusting the Air Flow Direction Horizontally Adjusting the Air Flow Direction VerticallyWhen To Cancel the Off Timer Setting the Off TimerOperating Recommendations Other FunctionTopic Recommendation Temperature and Humidity Ranges If the air conditioner is used at ThenCleaning Your Air Conditioner Solving Common Problems Problem Explanation/SolutionTechnical Specifications Power SupplyAccessory Parts List Part NameDrain plug Cable tie Putty Piping Pipe band Cover hole ScrewIndoor Unit Selection of Installation PlaceOutdoor Unit Electrical Work When using ELB Earth Leakage Circuit Breaker When using NFB No Fuse BreakerAP50Q1C Series When connecting 3Phase 3wires 220V AC AP55Q1C/AP55Q1D SeriesInstallation Procedures Connection of Refrigerant Piping Flare ProcessingPipe Bending Tightening of Connection PartsDrilling a Hole in the Wall Connecting the PipeDrain Hose Air Purge Refrigerant Charging Check and Test Operation CheckTest Operation Packing and Unpacking Guide Outdoor unit How to connect your extended power cables Wire tube power cable Connection sleeveQuestions or COMMENTS?