Samsung AP55Q1CNUMG, AP55Q1DNUMG Connection of Refrigerant Piping, Flare Processing, Pipe Bending

Page 27

Connection of Refrigerant Piping

When installing, make sure there is no leakage. When recovering the refrigerant, ground the compressor first before removing the connection pipe. If the refrigerant pipe is not properly connected and the compressor works with the service valve open, the pipe inhales the air and it makes the pressure inside of the refrigerant cycle abnormally high. It may cause explosion and injury.

Flare Processing

1. Cut the pipe using the pipe cutter.

90

Oblique

Roughness Burr

 

2. Insert the flare nut into the pipe, and then perform the flare processing.

Outer Diameter

A(mm)

9.52mm

1.8

19.05mm

2.2

Pipe Bending

A

1.Perform bending of the pipe using the bender which has a specified bending radius.

2.Be sure to take full care to perform bending of the pipe successfully at one time. Bending and unbending the pipe more than twice makes the bending work increasingly difficult.

3.You may use the spring inserted into the gas pipe instead of the bender to bend the pipe.

4.When you bend the pipe using the spring, hold the pipe with both hands to prevent any distortion, and secure a minimum bending radius of more than 100mm.

Spring

Tightening of Connection Parts

Align the center of the connection piping, and tighten the flare nut by turning it with hand. Then tighten it again using the torque wrench in the direction as shown in the figure.

Outer Diameter

Torque (kgf•cm)

Remarks

9.52mm

250~280

-

19.05mm

990~1210

-

E-27

AP50Q1C_IBIM_E 32202-2.indd 27

2010-07-14 오후 4:42:16

Image 27
Contents Air Conditioner Safety Precautions Contents Indoor Unit View of the UnitInserting the Remote Control Batteries Remote Control-ButtonsFor Operating PreparationCooling Your Room Select the fan speed by pressing Heating Your RoomSelecting the Automatic Operating Mode Changing the Room Temperature Quickly Operating to the Long Distance To adjust the temperature, pressRemoving Excess Humidity Airing Your Room Adjusting the Air Flow Direction Vertically Adjusting the Air Flow Direction HorizontallyWhen Setting the Off Timer To Cancel the Off TimerOther Function Operating RecommendationsTopic Recommendation If the air conditioner is used at Then Temperature and Humidity RangesCleaning Your Air Conditioner Problem Explanation/Solution Solving Common ProblemsPower Supply Technical SpecificationsCover hole Screw Accessory Parts ListPart Name Drain plug Cable tie Putty Piping Pipe bandSelection of Installation Place Indoor UnitOutdoor Unit Electrical Work When using NFB No Fuse Breaker When using ELB Earth Leakage Circuit BreakerAP50Q1C Series AP55Q1C/AP55Q1D Series When connecting 3Phase 3wires 220V ACInstallation Procedures Tightening of Connection Parts Connection of Refrigerant PipingFlare Processing Pipe BendingConnecting the Pipe Drilling a Hole in the WallDrain Hose Air Purge Refrigerant Charging Check Check and Test OperationTest Operation Packing and Unpacking Guide Outdoor unit Wire tube power cable Connection sleeve How to connect your extended power cablesQuestions or COMMENTS?