Samsung AQ12NBMD2/XSV, AQ12NBMDXSV manual OWNER’S Instructions

Page 1

OWNER’S

INSTRUCTIONS

Heat pump

Cooling only

AQ09NBMD

AS09NBMD

AQ12NBMD

AS12NBMD

Split-type Room Air Conditioner

E DB98-16064A(1)

Image 1
Contents OWNER’S Instructions Safety Precautions Contents Indoor Unit View of the UnitAir InletRear Air Outlet Connection Valve Remote Control Buttons and Display Getting Started Inserting the Remote Control Batteries Using with the indoor unit Even though you have lost your remote controlSelecting with the Remote Control Way FunctionSET Temp Selecting the Automatic Operating ModeCooling Your Room Heating Your Room Except the cooling only models You can select the Heat mode only in the heat pump modelsChanging the Room Temperature Quickly Removing Excess Humidity Airing Your Room Recommendation Adjusting the Air Flow Direction VerticallyAdjusting the Air Flow Direction Horizontally To Cancel the On Timer Setting the On TimerMinutes to 24 hours To Cancel the Off Timer Setting the Off TimerTo Cancel the Sleep Timer Setting the Sleep TimerTopic Recommendation Operating RecommendationsCleaning Your Air Conditioner Temperature and Humidity RangesMode Outdoor Temperature Indoor Temperature Indoor Humidity Have switched off the breaker used for the unitSolving Common Problems Technical Specifications Installing a Filter OptionModel Indoor unit Power Supply Installation Manual Safety Precautions Fixing the Unit in Position Indoor Unit Deciding Where to Install the Air ConditionerMm or more Accessories in the Indoor Unit Case Air Conditioner and AccessoriesThen follow Steps Fixing the Installation PlatePurging the Unit Connecting the Assembly CableHeat pump models Cooling only modelsTo install the drain hose, proceed as follows Installing and Connecting the Indoor Unit Drain HosePipe Installing and Connecting the Indoor Unit Assembly PipingUneven Thickness Cutting/Extending the PipingOne electric cable must be connected to the outdoor unit Connecting the Cables to the Outdoor UnitChecking Correct Earthing Fixing the Unit in Position Use Vacuum Pump as shown at the figure Connecting Up and Purging the CircuitIf you have used Then Performing Leak Tests To check for gas leaks on Then, using a leak detector CheckPlacing the Indoor Unit in Position Checking and Testing Operations Explaining Operations to the Owner This AIR Conditioner is Manufactured by