Samsung AQ12NBMDXSV, AQ12NBMD2/XSV manual Connecting the Cables to the Outdoor Unit

Page 36

INSTALLING THE OUTDOOR UNIT

Connecting the Cables to the Outdoor Unit

One electric cable must be connected to the outdoor unit:

Heat pump models

N1

1

2

3

N

L

Indoor unit

N1

1

2

3

E

 

 

 

 

 

 

 

Earth

 

 

 

 

 

terminal

N1

1

2

3

E

 

 

 

 

 

 

 

Earth

 

 

 

 

 

terminal

N1

1

2

3

Outdoor unit

 

 

 

 

Cooling only models

N1

1

N

L

Indoor unit

N1

1

 

E3

 

 

 

 

 

Earth

 

 

 

 

terminal

N1

1

 

E

 

 

 

 

 

Earth

 

 

 

 

terminal

N1

1

2

3

 

 

 

 

 

Outdoor unit

E-36

 

 

 

 

The assembly cable connecting the indoor unit to the outdoor unit

1Remove the terminal board cover on the side of the outdoor unit.

2Connect the assembly cable to terminals.

Each wire is labelled with the corresponding terminal number.

3Connect the earth wires to the earth terminals.

Refer to the page opposite for further details on how to check that earthing is correct.

4Replace the terminal board cover, carefully tightening the screw.

5Connect the power cable with the indoor unit.

Image 36
Contents OWNER’S Instructions Safety Precautions Contents View of the Unit Indoor UnitAir InletRear Air Outlet Connection Valve Remote Control Buttons and Display Getting Started Inserting the Remote Control Batteries Even though you have lost your remote control Using with the indoor unitSelecting with the Remote Control Way FunctionSelecting the Automatic Operating Mode SET TempCooling Your Room You can select the Heat mode only in the heat pump models Heating Your Room Except the cooling only modelsChanging the Room Temperature Quickly Removing Excess Humidity Airing Your Room Adjusting the Air Flow Direction Vertically RecommendationAdjusting the Air Flow Direction Horizontally Setting the On Timer To Cancel the On TimerMinutes to 24 hours Setting the Off Timer To Cancel the Off TimerSetting the Sleep Timer To Cancel the Sleep TimerOperating Recommendations Topic RecommendationTemperature and Humidity Ranges Cleaning Your Air ConditionerMode Outdoor Temperature Indoor Temperature Indoor Humidity Have switched off the breaker used for the unitSolving Common Problems Installing a Filter Option Technical SpecificationsModel Indoor unit Power Supply Installation Manual Safety Precautions Fixing the Unit in Position Deciding Where to Install the Air Conditioner Indoor UnitMm or more Air Conditioner and Accessories Accessories in the Indoor Unit CaseFixing the Installation Plate Then follow StepsConnecting the Assembly Cable Purging the UnitHeat pump models Cooling only modelsInstalling and Connecting the Indoor Unit Drain Hose To install the drain hose, proceed as followsInstalling and Connecting the Indoor Unit Assembly Piping PipeCutting/Extending the Piping Uneven ThicknessConnecting the Cables to the Outdoor Unit One electric cable must be connected to the outdoor unitChecking Correct Earthing Fixing the Unit in Position Connecting Up and Purging the Circuit Use Vacuum Pump as shown at the figureIf you have used Then To check for gas leaks on Then, using a leak detector Check Performing Leak TestsPlacing the Indoor Unit in Position Checking and Testing Operations Explaining Operations to the Owner This AIR Conditioner is Manufactured by