INSTALLING THE INDOOR UNIT

Fixing the Installation Plate

Before fixing the installation plate to a wall or window frame, you must determine the position of the 65 mm hole through which the cable, piping and hose pass to connect the indoor unit up to the outdoor unit. When facing the air conditioner in position on the wall, the piping and cable can be connected from the:

Right

Left

Rear (right or left)

1Determine the position of the pipe and drain hose hole using the right figure and drill the hole with an inner diameter of 65 mm so that it slants slightly downwards.

2

If you are fixing the indoor unit to a...

Then follow Steps...

 

 

 

 

Wall

3.

 

 

 

 

Window frame

4 to 6.

3Fix the installation plate to the wall in a manner appropriate to the weight of the indoor unit.

If you are mounting the plate on a concrete wall with anchor bolts, the anchor bolts must not project by more than 20 mm.

4Determine the positions of the wooden uprights to be attached to the window frame.

5Attach the wooden uprights to the window frame in a manner appropriate to the weight of the indoor unit.

6Using tapped screws, attach the installation plate to the wooden uprights, as illustrated in the last figure opposite.

Installation plate

 

Pipe hole

30mm

(Ø65mm)

 

(Unit : mm)

 

 

60

252

275

 

30

90

140

(Unit : mm)

410~730

E-31

Image 31
Contents OWNER’S Instructions Safety Precautions Contents Indoor Unit View of the UnitAir InletRear Air Outlet Connection Valve Remote Control Buttons and Display Getting Started Inserting the Remote Control Batteries Way Function Even though you have lost your remote controlUsing with the indoor unit Selecting with the Remote ControlSET Temp Selecting the Automatic Operating ModeCooling Your Room Heating Your Room Except the cooling only models You can select the Heat mode only in the heat pump modelsChanging the Room Temperature Quickly Removing Excess Humidity Airing Your Room Recommendation Adjusting the Air Flow Direction VerticallyAdjusting the Air Flow Direction Horizontally To Cancel the On Timer Setting the On TimerMinutes to 24 hours To Cancel the Off Timer Setting the Off TimerTo Cancel the Sleep Timer Setting the Sleep TimerTopic Recommendation Operating RecommendationsHave switched off the breaker used for the unit Temperature and Humidity RangesCleaning Your Air Conditioner Mode Outdoor Temperature Indoor Temperature Indoor HumiditySolving Common Problems Technical Specifications Installing a Filter OptionModel Indoor unit Power Supply Installation Manual Safety Precautions Fixing the Unit in Position Indoor Unit Deciding Where to Install the Air ConditionerMm or more Accessories in the Indoor Unit Case Air Conditioner and AccessoriesThen follow Steps Fixing the Installation PlateCooling only models Connecting the Assembly CablePurging the Unit Heat pump modelsTo install the drain hose, proceed as follows Installing and Connecting the Indoor Unit Drain HosePipe Installing and Connecting the Indoor Unit Assembly PipingUneven Thickness Cutting/Extending the PipingOne electric cable must be connected to the outdoor unit Connecting the Cables to the Outdoor UnitChecking Correct Earthing Fixing the Unit in Position Use Vacuum Pump as shown at the figure Connecting Up and Purging the CircuitIf you have used Then Performing Leak Tests To check for gas leaks on Then, using a leak detector CheckPlacing the Indoor Unit in Position Checking and Testing Operations Explaining Operations to the Owner This AIR Conditioner is Manufactured by