Samsung AQ12NBMDXSV, AQ12NBMD2/XSV Temperature and Humidity Ranges, Cleaning Your Air Conditioner

Page 22

Temperature and Humidity Ranges

The following table indicates the temperature and humidity ranges within which the air conditioner can be used.

If the air conditioner is used at...

Then...

 

 

 

 

High temperatures

The automatic protection feature may be triggered and the air conditioner stopped.

 

 

 

 

Low temperatures

A water leak or some other malfunction may occur if the heat exchanger freezes.

 

 

 

 

High humidity levels

Water may condense on and drip from the surface of the indoor unit if it is used for long periods.

 

 

 

 

 

 

 

 

Mode

Outdoor Temperature

Indoor Temperature

Indoor Humidity

Heating

0°C to 24°C approx.

27°C or less

-

Cooling

21°C to 43°C approx.

18°C to 32°C approx.

80% or less

Drying

18°C to 43°C approx.

18°C to 32°C approx.

-

If the heating operation is used at below 0°C(outdoor temperature), it does not heat as its full capacity. If the cooling operation is used at over 33°C(indoor temperature), it does not cool as its full capacity.

Cleaning Your Air Conditioner

For the best use of your air conditioner, you must clean it regularly to remove the dust that accumulates on the air filter.

IMPORTANT

Before cleaning your air conditioner, ensure that you

 

have switched off the breaker used for the unit.

1Open the front grille by lifting the tabs on the lower right and left sides of

the indoor unit.

2 Disassemble the front grille by pulling it forwards.

3 Hold the edge of the air filter under the front grille and pull to release them.

4Remove all dust on the air filters with a vacuum cleaner or brush.

5 Clean the front panel with a damp cloth and mild detergent (do NOT use benzene, solvents or other chemicals).

6 Reassemble the air filters and the front grille.

If you have not used the air conditioner for a long period of time, set the fan going for three to four hours to dry the inside of the air conditioner thoroughly.

E-22

Image 22
Contents OWNER’S Instructions Safety Precautions Contents View of the Unit Indoor UnitAir InletRear Air Outlet Connection Valve Remote Control Buttons and Display Getting Started Inserting the Remote Control Batteries Selecting with the Remote Control Even though you have lost your remote controlUsing with the indoor unit Way FunctionSelecting the Automatic Operating Mode SET TempCooling Your Room You can select the Heat mode only in the heat pump models Heating Your Room Except the cooling only modelsChanging the Room Temperature Quickly Removing Excess Humidity Airing Your Room Adjusting the Air Flow Direction Vertically RecommendationAdjusting the Air Flow Direction Horizontally To Cancel the On Timer Setting the On TimerMinutes to 24 hours Setting the Off Timer To Cancel the Off TimerSetting the Sleep Timer To Cancel the Sleep TimerOperating Recommendations Topic RecommendationMode Outdoor Temperature Indoor Temperature Indoor Humidity Temperature and Humidity RangesCleaning Your Air Conditioner Have switched off the breaker used for the unitSolving Common Problems Technical Specifications Installing a Filter OptionModel Indoor unit Power Supply Installation Manual Safety Precautions Fixing the Unit in Position Deciding Where to Install the Air Conditioner Indoor UnitMm or more Air Conditioner and Accessories Accessories in the Indoor Unit CaseFixing the Installation Plate Then follow StepsHeat pump models Connecting the Assembly CablePurging the Unit Cooling only modelsInstalling and Connecting the Indoor Unit Drain Hose To install the drain hose, proceed as followsInstalling and Connecting the Indoor Unit Assembly Piping PipeCutting/Extending the Piping Uneven ThicknessConnecting the Cables to the Outdoor Unit One electric cable must be connected to the outdoor unitChecking Correct Earthing Fixing the Unit in Position Use Vacuum Pump as shown at the figure Connecting Up and Purging the CircuitIf you have used Then To check for gas leaks on Then, using a leak detector Check Performing Leak TestsPlacing the Indoor Unit in Position Checking and Testing Operations Explaining Operations to the Owner This AIR Conditioner is Manufactured by