PREPARING THE INSTALLATION

Respect the clearances and maximum lengths indicated in the diagram below when installing the unit.

 

300 mm or more

125 mm

125 mm

or more

or more

Wrap the refrigerant pipes and the drain

 

hose up in the absorbent pad and the

 

vinyl tape; refer to page 41.

7 metres maximum

600 mm

15 metres maximum

 

minimum

 

100 mm minimum

100 mm minimum

350 mm minimum

600 mm minimum

The designs of the unit and the connection valve are subject to change according to the model.

E-29

Image 29
Contents OWNER’S Instructions Safety Precautions Contents Indoor Unit View of the UnitAir InletRear Air Outlet Connection Valve Remote Control Buttons and Display Getting Started Inserting the Remote Control Batteries Using with the indoor unit Even though you have lost your remote controlSelecting with the Remote Control Way FunctionSET Temp Selecting the Automatic Operating ModeCooling Your Room Heating Your Room Except the cooling only models You can select the Heat mode only in the heat pump modelsChanging the Room Temperature Quickly Removing Excess Humidity Airing Your Room Recommendation Adjusting the Air Flow Direction VerticallyAdjusting the Air Flow Direction Horizontally Minutes to 24 hours Setting the On TimerTo Cancel the On Timer To Cancel the Off Timer Setting the Off TimerTo Cancel the Sleep Timer Setting the Sleep TimerTopic Recommendation Operating RecommendationsCleaning Your Air Conditioner Temperature and Humidity RangesMode Outdoor Temperature Indoor Temperature Indoor Humidity Have switched off the breaker used for the unitSolving Common Problems Model Indoor unit Power Supply Installing a Filter OptionTechnical Specifications Installation Manual Safety Precautions Fixing the Unit in Position Indoor Unit Deciding Where to Install the Air ConditionerMm or more Accessories in the Indoor Unit Case Air Conditioner and AccessoriesThen follow Steps Fixing the Installation PlatePurging the Unit Connecting the Assembly CableHeat pump models Cooling only modelsTo install the drain hose, proceed as follows Installing and Connecting the Indoor Unit Drain HosePipe Installing and Connecting the Indoor Unit Assembly PipingUneven Thickness Cutting/Extending the PipingOne electric cable must be connected to the outdoor unit Connecting the Cables to the Outdoor UnitChecking Correct Earthing Fixing the Unit in Position If you have used Then Connecting Up and Purging the CircuitUse Vacuum Pump as shown at the figure Performing Leak Tests To check for gas leaks on Then, using a leak detector CheckPlacing the Indoor Unit in Position Checking and Testing Operations Explaining Operations to the Owner This AIR Conditioner is Manufactured by