Samsung AQ12NBMDXSV, AQ12NBMD2/XSV manual Performing Leak Tests

Page 40

COMPLETING THE INSTALLATION

Performing Leak Tests

C D

B

A

Before completing the installation (insulation of the cables, hose and piping and fixing of the indoor unit to the installation plate), you must check that there are no gas leaks.

To check for gas leaks on the...

Then, using a leak detector,

 

check the...

 

 

Indoor unit

Flare nuts at the end of sections

 

C and D.

 

 

Outdoor unit

Valves on sections A and B.

 

 

E-40

Image 40
Contents OWNER’S Instructions Safety Precautions Contents View of the Unit Indoor UnitAir InletRear Air Outlet Connection Valve Remote Control Buttons and Display Getting Started Inserting the Remote Control Batteries Even though you have lost your remote control Using with the indoor unitSelecting with the Remote Control Way FunctionSelecting the Automatic Operating Mode SET TempCooling Your Room You can select the Heat mode only in the heat pump models Heating Your Room Except the cooling only modelsChanging the Room Temperature Quickly Removing Excess Humidity Airing Your Room Adjusting the Air Flow Direction Vertically RecommendationAdjusting the Air Flow Direction Horizontally To Cancel the On Timer Setting the On TimerMinutes to 24 hours Setting the Off Timer To Cancel the Off TimerSetting the Sleep Timer To Cancel the Sleep TimerOperating Recommendations Topic RecommendationTemperature and Humidity Ranges Cleaning Your Air ConditionerMode Outdoor Temperature Indoor Temperature Indoor Humidity Have switched off the breaker used for the unitSolving Common Problems Technical Specifications Installing a Filter OptionModel Indoor unit Power Supply Installation Manual Safety Precautions Fixing the Unit in Position Deciding Where to Install the Air Conditioner Indoor UnitMm or more Air Conditioner and Accessories Accessories in the Indoor Unit CaseFixing the Installation Plate Then follow StepsConnecting the Assembly Cable Purging the UnitHeat pump models Cooling only modelsInstalling and Connecting the Indoor Unit Drain Hose To install the drain hose, proceed as followsInstalling and Connecting the Indoor Unit Assembly Piping PipeCutting/Extending the Piping Uneven ThicknessConnecting the Cables to the Outdoor Unit One electric cable must be connected to the outdoor unitChecking Correct Earthing Fixing the Unit in Position Use Vacuum Pump as shown at the figure Connecting Up and Purging the CircuitIf you have used Then To check for gas leaks on Then, using a leak detector Check Performing Leak TestsPlacing the Indoor Unit in Position Checking and Testing Operations Explaining Operations to the Owner This AIR Conditioner is Manufactured by