Samsung AQ12NBMDXSV, AQ12NBMD2/XSV Deciding Where to Install the Air Conditioner, Indoor Unit

Page 28

PREPARING THE INSTALLATION

Deciding Where to Install the Air Conditioner

When deciding on the location of the air conditioner with the owner, the following restrictions must be taken into account.

General

Do NOT install the air conditioner in a location where it will come into contact with the following elements:

Combustible gases

Saline air

Machine oil

Sulphide gas

Special environmental conditions

If you must install the unit in such conditions, first consult your dealer.

Indoor Unit

There must be no obstacles near the air inlet and outlet.

Install the indoor unit on a surface that can support its weight.

Choose a position that enables the piping and cables to be easily connected to the outdoor unit and the recommend- ed length of 5 metres to be respected (15 metres maximum).

Leave enough clearance beneath the indoor unit to enable the filters to be removed without hindrance.

Maintain sufficient clearance around the indoor unit, as indicated in the diagram on the page opposite.

Make sure that the water dripping from the drain hose runs away correctly and safely.

Outdoor Unit

The outdoor unit must NEVER be placed on its side or upside down, as the compressor lubrication oil will run into the cooling circuit and seriously damage the unit.

Choose a location that is dry and sunny, but not exposed to direct sunlight or strong winds.

Do not block any passageways or thoroughfares.

Choose a location where the noise of the air conditioner when running and the discharged air do not disturb any neighbours.

Choose a position that enables the piping and cables to be easily connected to the indoor unit and the recommended length of 5 metres to be respected (15 metres maximum).

Install the outdoor unit on a flat, stable surface that can support its weight and does not generate any unnecessary noise and vibration.

Position the outdoor unit so that the air flow is directed towards the outside, as indicated by the arrows on the top of the unit.

Maintain sufficient clearance around the outdoor unit, as indicated in the diagram on the page opposite.

If the outdoor unit is installed at a height, ensure that its base is firmly fixed in position; the maximum height is 7 metres.

Make sure that the water dripping from the drain hose runs away correctly and safely.

CAUTION

You have just purchased a split-type room air conditioner and it has been installed by your installation specialist.

This device must be installed according to the national electrical rules.

E-28

Image 28
Contents OWNER’S Instructions Safety Precautions Contents View of the Unit Indoor UnitAir InletRear Air Outlet Connection Valve Remote Control Buttons and Display Getting Started Inserting the Remote Control Batteries Even though you have lost your remote control Using with the indoor unitSelecting with the Remote Control Way FunctionSelecting the Automatic Operating Mode SET TempCooling Your Room You can select the Heat mode only in the heat pump models Heating Your Room Except the cooling only modelsChanging the Room Temperature Quickly Removing Excess Humidity Airing Your Room Adjusting the Air Flow Direction Vertically RecommendationAdjusting the Air Flow Direction Horizontally To Cancel the On Timer Setting the On TimerMinutes to 24 hours Setting the Off Timer To Cancel the Off TimerSetting the Sleep Timer To Cancel the Sleep TimerOperating Recommendations Topic RecommendationTemperature and Humidity Ranges Cleaning Your Air ConditionerMode Outdoor Temperature Indoor Temperature Indoor Humidity Have switched off the breaker used for the unitSolving Common Problems Technical Specifications Installing a Filter OptionModel Indoor unit Power Supply Installation Manual Safety Precautions Fixing the Unit in Position Deciding Where to Install the Air Conditioner Indoor UnitMm or more Air Conditioner and Accessories Accessories in the Indoor Unit CaseFixing the Installation Plate Then follow StepsConnecting the Assembly Cable Purging the UnitHeat pump models Cooling only modelsInstalling and Connecting the Indoor Unit Drain Hose To install the drain hose, proceed as followsInstalling and Connecting the Indoor Unit Assembly Piping PipeCutting/Extending the Piping Uneven ThicknessConnecting the Cables to the Outdoor Unit One electric cable must be connected to the outdoor unitChecking Correct Earthing Fixing the Unit in Position Use Vacuum Pump as shown at the figure Connecting Up and Purging the CircuitIf you have used Then To check for gas leaks on Then, using a leak detector Check Performing Leak TestsPlacing the Indoor Unit in Position Checking and Testing Operations Explaining Operations to the Owner This AIR Conditioner is Manufactured by