Samsung AQ12NBMD2/XSV, AQ12NBMDXSV manual Placing the Indoor Unit in Position

Page 41

COMPLETING THE INSTALLATION

Placing the Indoor Unit in Position

Once you have checked that there are no leaks in the system, you can insulate the piping, hose and cables and place the indoor unit on the installation plate.

1To avoid condensation problems, place heat-resistant polyethylene foam separately around each refrigerant pipe in the lower part of the indoor unit.

2Wrap the refrigerant pipes and the drain hose located at the rear of the indoor unit up in the absorbent pad.

Triply wind the pipes and hose to the end of the indoor unit with the absorbent pad (make intervals of 20mm).

3Wind insulating tape around the pipes, assembly cable and drain hose.

4Place the resulting bundle carefully in the lower part of the indoor unit, making sure that it does not jut out from the rear of the indoor unit.

5Hook the indoor unit on to the installation plate and move the unit to the right and left until you are sure that it is securely in place.

6Finish wrapping vinyl tape around the rest of the piping leading to the outdoor unit.

7Using clamps (optionally supplied), attach the piping to the wall wherever possible.

Installation plate

E-41

Image 41
Contents OWNER’S Instructions Safety Precautions Contents Indoor Unit View of the UnitAir InletRear Air Outlet Connection Valve Remote Control Buttons and Display Getting Started Inserting the Remote Control Batteries Using with the indoor unit Even though you have lost your remote controlSelecting with the Remote Control Way FunctionSET Temp Selecting the Automatic Operating ModeCooling Your Room Heating Your Room Except the cooling only models You can select the Heat mode only in the heat pump modelsChanging the Room Temperature Quickly Removing Excess Humidity Airing Your Room Recommendation Adjusting the Air Flow Direction VerticallyAdjusting the Air Flow Direction Horizontally Minutes to 24 hours Setting the On TimerTo Cancel the On Timer To Cancel the Off Timer Setting the Off TimerTo Cancel the Sleep Timer Setting the Sleep TimerTopic Recommendation Operating RecommendationsCleaning Your Air Conditioner Temperature and Humidity RangesMode Outdoor Temperature Indoor Temperature Indoor Humidity Have switched off the breaker used for the unitSolving Common Problems Model Indoor unit Power Supply Installing a Filter OptionTechnical Specifications Installation Manual Safety Precautions Fixing the Unit in Position Indoor Unit Deciding Where to Install the Air ConditionerMm or more Accessories in the Indoor Unit Case Air Conditioner and AccessoriesThen follow Steps Fixing the Installation PlatePurging the Unit Connecting the Assembly CableHeat pump models Cooling only modelsTo install the drain hose, proceed as follows Installing and Connecting the Indoor Unit Drain HosePipe Installing and Connecting the Indoor Unit Assembly PipingUneven Thickness Cutting/Extending the PipingOne electric cable must be connected to the outdoor unit Connecting the Cables to the Outdoor UnitChecking Correct Earthing Fixing the Unit in Position If you have used Then Connecting Up and Purging the CircuitUse Vacuum Pump as shown at the figure Performing Leak Tests To check for gas leaks on Then, using a leak detector CheckPlacing the Indoor Unit in Position Checking and Testing Operations Explaining Operations to the Owner This AIR Conditioner is Manufactured by