Delta AP-100 instruction manual Extension Cords, All grounded, cord-connected machines

Page 6

1.All grounded, cord-connected machines:

In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This machine is equipped with an electric cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Do not modify the plug provided - if it will not fit the outlet, have the proper outlet installed by a qualified electrician.

Improper connection of the equipment-grounding conduc-tor can result in risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding conductor. If repair or replacement of the electric cord or plug is necessary, do not connect the equipment-grounding conductor to a live terminal.

Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt a s to whether the machine is properly grounded.

Use only 3-wire extension cords that have 3-prong grounding type plugs and matching 3-conductor receptacles that accept the machine’s plug, as shown in Fig. A.

Repair or replace damaged or worn cord immediately.

2.Grounded, cord-connected machines intended for use on a supply circuit having a nominal rating less than 150 volts:

If the machine is intended for use on a circuit that has an outlet that looks like the one illustrated in Fig. A, the machine will have a grounding plug that looks like the plug illustrated in Fig. A. A temporary adapter, which looks like the adapter illustrated in Fig. B, may be used to connect this plug to a matching 2-conductor receptacle as shown in Fig. B if a properly grounded outlet is not available. The temporary adapter should be used only until a properly grounded outlet can be installed by a qualified electrician. The green-colored rigid ear, lug, and the like, extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. Whenever the adapter is used, it must be held in place with a metal screw.

NOTE: In Canada, the use of a temporary adapter is not permitted by the Canadian Electric Code.

In all cases, make certain that the receptacle in question is properly grounded. If you are not sure, have a qualified electrician check the receptacle.

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

GROUNDED OUTLET BOX

GROUNDING MEANS

ADAPTER

GROUNDING BLADE

IS LONGEST OF THE 3 BLADES

Fig. A

EXTENSION CORDS

Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension cord which has a 3-prong grounding type plug and matching receptacle which will accept the machine’s plug. When using an extension cord, be sure to use one heavy enough to carry the current of the machine. An undersized cord will cause a drop in line voltage, resulting in loss of power and overheating. Fig. D-1 shows the correct gauge to use depending on the cord length. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.

Fig. B

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES

 

 

Total

 

Ampere

 

Length of

 

 

Cord in

Gauge of Extension

 

 

Rating

Volts

Feet

Cord

0-6

120

up to 25

18 AWG

0-6

120

25-50

16 AWG

0-6

120

50-100

16 AWG

0-6

120

100-150

14 AWG

6-10

120

up to 25

18 AWG

6-10

120

25-50

16 AWG

6-10

120

50-100

14 AWG

6-10

120

100-150

12 AWG

10-12

120

up to 25

16 AWG

10-12

120

25-50

16 AWG

10-12

120

50-100

14 AWG

10-12

120

100-150

12 AWG

12-16

120

up to 25

14 AWG

12-16

120

25-50

12 AWG

12-16

120

GREATER THAN 50 FEET NOT RECOMMENDED

 

 

Fig. D-1

6

Image 6
Contents Contractors Saw Table of Contents Important Safety InstructionsSafety Guidelines Definitions California PropositionGeneral Safety Rules Stay ALERT, Watch What YOU are DOING, and USEMotor Specifications Additional Specific Safety RulesPower Connections Grounding InstructionsExtension Cords All grounded, cord-connected machinesCarton Contents Functional DescriptionAssembly Cord Switch OperationMotor and Light Pull Cords Troubleshooting Maintenance Changing and Cleaning FiltersKeep the Unit Clean Light StarterWarranty ServiceAccessories Replacement PartsFrançais LES Instructions Importantes DE Surete Mesures DE Sécurité DéfinitionsLA Proposition DE Californie Règles DE Sécurité Générales Lutilisation DE CET Outil PeutSpécifications DU Moteur Règles Spécifiques Additionnelles DE SûretéRaccordements Électriques Instructions DE Mise À LA TerreCordon DE Rallonge Mesur Minimum DE Corde D’EXTENSIONAVANT-PROPOS Description FonctionnelleContenus DE Boite Désemballage ET NettoyageAssemblage Fonctionnement Interrupteur DU CordonCordons DE Tirage DU Moteur ET D’ÉCLAIRAGE Depannage Maintenance Changer ET Nettoyer LES FiltresDémarreurs D’ÉCLAIRAGE Garder LA Machine PropreDémarrage Impossible Accessoiries Pièces DE RechangeEntretien ET Réparation Garantie Garantie limitée de deux ansEspañol Instrucciones DE Seguridad Importantes Pautas DE SEGURIDAD/DEFINICIONESProposición DE California Normas Generales DE Seguridad EL USO DE Esta HerramientaEspecificaciones DEL Motor Normas Específicas Adicionales DE SeguridadConexiones a LA Fuente DE Alimentación Instrucciones DE Conexión a TierraCordones DE Extensión Descripción Funcional Contenido DE CartonDesempaquetado Y Limpieza Ensamblaje Operación Interruptores DE Cordón Para EL Motor Y LA LUZLocalizacion DE Fallas Mantenimiento Reemplazo Y Limpieza DE LOS FiltrosArrancadores Service Plane , Whisper SERIES,WOODWORKER’S Choice