ASSEMBLY
For your own safety, do not connect the machine to the power source until the machine is completely assembled and you read and understand the entire instruction manual.
ASSEMBLY TOOLS REQUIRED
No assembly tools are required.
ASSEMBLY TIME ESTIMATE
Assembly for this machine takes approximately 30 minutes.
PULL CORDS
Insert the cord (A) Fig. 1 in the pull cord catch (B). Repeat this process for the remaining pull cord.
FLUORESCENT BULBS (NOT INCLUDED)
IMPORTANT: This unit uses standard 18"x1", 15 watt fluorescent light bulbs.
1.Insert one end of the bulb (A) Fig. 2 through the slot (B). Repeat this step for the other end of the bulb.
2.Twist the bulb 1/4 turn to lock it in place.
3.Repeat this process for the remaining bulb.
B
A
A
B
Fig. 1 |
|
|
| Fig. 2 | |
|
|
|
MOUNTING THE AIR CLEANER TO THE CEILING OR OVERHEAD SUPPOR
1.Thread a
2.Thread the
NOTE: Tighten the
3.Tighten the flange nut (B) Fig. 3 against the air cleaner.
4.Repeat this process for the remaining hole in the top of the air cleaner (Fig. 4).
This tool weighs approximately 40 pounds. Make certain the unit is securely supported when mounting it to a ceiling or overhead support.
Never secure the air cleaner hardware to drywall, drop ceiling tile/frame, or other
C
B
D
Fig. 3
Fig. 4
8