Desa RCLP50B owner manual Motor Continued

Page 12
Motor (Continued)

Motor (Continued)

10.Attach fan guard to new motor with three nuts. Tighten nuts firmly.

11.Place fan onto motor shaft of new motor.

IMPORTANT: When placing fan onto motor shaft, make sure part number stamped on fan is facing motor. Attach fan nut to end of motor shaft. Tighten fan nut firmly.

12.Place motor and fan guard into rear of heater shell. Carefully route motor wires through hole in shell (see Figure 10).

13.Insert three screws through heater shell and into fan guard. Tighten screws firmly.

14.Turn heater on its side to access opening in bottom of base. Connect green motor wire and green power cord wire to heater shell using ground nut (see Figure 6, page 11).

15.Attach black and white wires to empty connectors on black and white wire sides of terminal board.

16.Attach wire guard to shell with two screws (see Figure 6, page 11).

Fan

1.Remove fan and motor (see Motor, page 11, steps 1 through 6.

2a. If replacing fan, remove old fan and discard. Go to step 5 below.

2b. If cleaning fan, remove fan. Be careful not to damage the fan blade pitch.

3.Clean fan using soft cloth moistened with kerosene or solvent.

4.Dry fan thoroughly.

5.To replace fan, follow steps 11 through 16 above.

12

Hole in Shell for Motor Wires

Figure 10 - Replacing Motor and Fan Guard into Heater

103911

Image 12
Contents Model RCLP50B CANADIAN PROPANE CONSTRUCTION HEATERCONTENTS SAFETY INFORMATION WARNINGSSAFETY INFORMATION WARNINGS ContinuedContinued UNPACKING PRODUCT IDENTIFICATIONTHEORY OF OPERATIONSUPPLY PROPANEINSTALLATION Figure 4 - Hose and Inlet ConnectorFigure 3 - Regulator Position VENTILATION OPERATION To Start HeaterOPERATION ContinuedTo Stop Heater To Restart HeaterSTORAGE MAINTENANCE WARNINGSDisconnect heater from propane supply tanks TROUBLE- SHOOTING OBSERVED FAULTUse only in areas free of high dust content POSSIBLE CAUSESERVICE PROCEDURES MotorMotor Continued causing severe burns IgnitorWARNING Make sure from propane supplySPECIFICATIONS WIRING DIAGRAMS ACCESSORIES TECHNICAL SERVICE REPLACEMENT PARTSPart Number DescriptionILLUSTRATED PARTSBREAKDOWN RUBBERPARTS LIST PARTDESCRIPTION PARTS AVAILABLE - NOT SHOWNWARRANTY AND REPAIR SERVICE DESA Industries of Canada, IncKEEP THIS WARRANTY LIMITED WARRANTY WARRANTY SERVICEMANUEL D’UTILISATION Modèle RCLP50BAPPAREIL DE TABLE DES MATIÈRES INFORMATIONS CONCERNANT LA SÉCURITÉAVERTISSEMENT AVERTISSEMENTS suite suiteINFORMATIONS CONCERNANT LA SÉCURITÉ DÉ BALLAGE INFORMATIONS CONCERNANT LA SÉ CURITÉIDENTIFICATION DU PRODUIT AVERTISSEMENTS suitePRINCIPE DE FONCTIONNEMENTEN PROPANE ALIMENTATIONINSTALLATION AVERTISSEMENTAVERTISSEMENT Robinet d’arrêt de propaneVENTILATION FONCTIONNEMENTAVERTISSEMENT AVERTISSEMENTFONCTIONNEMENT AVERTISSEMENTsuite Arrê t de l’appareilREMISAGE ENTRETIEN AVERTISSEMENTSDÉ PANNAGE AVERTISSEMENTAVERTISSEMENT PROBLÈ MEPROCÉ DURES D’ENTRETIEN AVERTISSEMENTMoteur Moteur suite VentilateurAllumeur CARACTÉ RIS- TIQUES SCHÉ MAS DE CÂ BLAGEACCESSOIRES SERVICE TECHNIQUEPIÈ CES DÉ TACHÉ ES AVERTISSEMENTVUE É CLATÉ E DES PIÈ CESRondelle en caoutchoucLISTE DES PIÈ CES PIÈ CEN DE RÉ F DESCRIPTIONGARANTIE ET SERVICE APRÈ S-VENTE SERVICE DE RÉ PARATIONSDESA Industries of Canada, Inc CONSERVER CETTE GARANTIE GARANTIE LIMITÉ E