1.Convection Blower Replacement

a. Turn down thermostat, let appliance completely cool and then unplug appliance before servicing.

b.The convection blower is located at the bottom rear of the appliance and is housed inside a screen box. Remove the 2 screws facing forward in the center of the blower chamber at the very back of the appliance.

c.If an outside air kit is installed on the appliance, these screws attach the intake air channel piece of the outside air kit to the appliance. Remove the 2 screws and pull backwards on the channel and it will slide down and away from the appliance. The air channel, collar and outside air hose will be removed as one piece.

d.Remove the 4 screws that attach the blower housing to the appliance, 2 on each side. Loosen all 4 screws, but do not remove them. Lift the blower housing up slightly and slide towards you. Figure 31.1.

e.Remove the left side panel by loosening 2 screws (do not remove) and pull side panel away. Unplug the 2 black blower wires by disconnecting the spade connectors.

f.To remove blower from the housing, remove 2 screws in the front of the housing and very carefully bend the 2 housing sides out and bend the back of the housing away from the blower. This allows for room to access the back 2 screws and nuts (4 total) that is securing the blower to the housing.

g.Remove blower and replace with new blower.

e. Re-install in reverse order.

Remove left side panel and discon- nect blower wires

Convection Blower

Loosen (do not remove) 2 & Housing screws on each side and lift

off blower housing

Figure 31.1

2.Exhaust Blower Replacement

NOTE: The convection blower must be removed before the exhaust blower can be removed.

a.Turn down thermostat, let appliance completely cool and then unplug appliance before servicing.

bRemove both side curtains by loosening 2 screws (do not remove) and pull side panels away.

c.Remove 7 screws from the back screen and pivot the top of the screen toward you leaving the bottom attached to stove. Figure 31.2.

d.Remove 2 screws to remove the thermostat block and disconnect the 2 yellow wires.

e.Remove the 2 screws from the power inlet and rotate it through the hole and out of the screen, leaving the wires attached.

f.Disconnect the vacuum hose and both wires (orange and red) from the vacuum switch attached to the rear screen.

g.Remove both wires from exhaust blower (blue and double white).

h.Remove 6 screws using a flathead screwdriver or a 1/4" nutdriver. Retain screws for use on replacement blower.

Figure 31.3.

i.Remove exhaust blower and gasket.

j.Install new gasket and blower. Discard blower housing if not needed.

k.Re-install in reverse order.

 

 

 

 

 

 

 

 

Remove 7 screws and bend top back

 

 

 

 

 

 

leaving it attached at the bottom.

 

 

 

Remove 6 screws

 

 

 

 

 

 

 

 

Figure 31.2

 

 

Figure 31.3

 

Exhaust

Blower

Figure 31.4

October 11,, 2005

250-6422D

Page 31

Image 31
Contents Castile Pellet Stove Location Back side of left side panel Castile Pellet StoveTable of Contents Listing and Code Approvals Thermostat Location Design, Installation & Location Fire Safety ConsiderationsGetting Started Appliance LocationFire Risk Castile Pellet Stove Tools And Supplies NeededMeasuring Standards Inspect Appliance & Components and Pre-Use Check ListAppliance Dimensions 3Dimensions and ClearancesCastile Pellet Stove Clearances to Combustibles UL and ULC Castile Pellet Stove Hearth Pad Requirements UL and ULC Exception for Horizontal InstallationsHearth Pad Requirements Chimney and Exhaust Connection Vent InformationVenting Termination Requirements See Figure Pipe Selection ChartCastile Pellet Stove Equivalent Feet of Pipe Example of 3 Elbow-Rear Vent Termination CalculatonAlcove Venting SystemsDegree Straight OutCastile Pellet Stove Through The Wall Through The Wall & Vertical Castile Pellet Stove VerticalAlternate Masonry Castile Pellet Stove MasonryMobile Home Outside Air Kit Instructions 7Appliance Set-UpCastile Pellet Stove Leg Leveling System Top Vent Adapter InstallationRear Vent and Rear Vent to Top Vent Adapter Installation Installing the Top Vent AdapterOptional TOP LOG Castile Pellet Stove Thermostat Installation Fuel Size And Material General Operating Information Operating InstructionsStarting Your First Fire Fire CharacteristicsFeed Rate Adjustment Instructions Castile Pellet Stove Before Your First FireCastile Pellet Stove Iginition Cycles Frequently Asked QuestionsSymption TroubleshootingPossible Cause Corrective Action Page Page Task Cleaning Ash Pan Frequency As needed10Maintaining & Servicing Your Appliance Types of FuelHeat Exchanger Tubes Cleaning RodsCleaning Exhaust Blower Requires No Lubrication Cleaning the Exhaust Path Frequency As neededCleaning the Hopper Cleaning Convection Blower Requires No LubricationSection Castile Pellet Stove High Ash Fuel Content MaintenanceExhaust Blower Replacement Convection Blower ReplacementThumb Screw Igniter ReplacementGlass Replacement Component Function Reference MaterialsSnap Disc #2 Thermostat Override 175tF Vacuum SwitchWiring Harness See .1 below Snap Disc #1 Convection Blower 125FCastile Pellet Stove Component Locations Description Part Number Castile Pellet Stove Exploded ViewsPart Description Beg. Manufacture Date SeptemberService Parts Castile Pellet Stove Service Parts and AccessoriesAppliances AccessoriesDate of Service Performed By Description of Service Service and Maintenance LOGCastile Pellet Stove Service and Maintenance LOG Cont’d Castile Pellet Stove Warranty Policy Lifetime WarrantyTelephone Contact Information