Quadra-Fire 810-02901 Castile Pellet Insert, Insurance carrier, local, Building inspector, fi re

Page 2

R

Castile Pellet Insert

Hearth & Home Technologies welcomes you to our

SAMPLE OF CLEARANCE TO COMBUSTIBLES LABEL

tradition of excellence! In choosing a Quadra-Fire

LOCATION: On beaded chain behind right access

appliance, you have our assurance of commitment

panel. Panel hinges open.

to quality, durability, and performance.

 

 

 

This commitment begins with our research of the

 

 

 

SAFETY LABEL

 

 

 

market, including ‘Voice of the Customer’ contacts,

Listed by

O-T L Oregon USA

 

 

 

 

 

Manufactured by:

 

 

 

 

 

Tested and

Portland

 

 

 

 

R

 

 

 

ensuring we make products that will satisfy your

C

US

 

 

 

 

 

 

 

 

OMNI-Test Laboratories, Inc.

 

 

 

 

 

 

 

 

needs.

 

 

 

Report No.

 

Castile Pellet Insert

1445 Highway North, Colville, WA 99114

 

 

 

 

 

 

 

 

www.quadrafire.com

 

 

 

#061-S-42-2

 

Input Rating: 30,000 BTU/HR.

 

 

 

 

 

 

 

 

Our Research and

Development

facility

then

 

Electrical Rating: 115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 AMPS.

 

 

Listed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for Mobile Home Installation. This

employs the world’s most advanced technology

appliance has been tested and listed for use in Manufactured Homes in accordance with OAR

814-23-9000 through 814-23-909.

 

 

 

 

 

 

to achieve the optimum operation of our stoves,

Tested to: ASTM E-1509-95, ULC S628-93, ULC /ORD-C1482-M1990 Room Heating Pellet Burning Type,

 

 

 

 

(UM) 84-HUD FOR USE ONLY WITH PELLETIZED WOOD OR SHELLED FIELD CORN FUEL.

 

 

inserts and fi replaces.

And yet we are old-fash-

 

SAMPLE

 

 

 

Route power cord away from unit. Do not route cord under or in front of appliance.

 

 

ioned when it comes to craftsmanship. Each unit

 

 

 

 

 

 

 

 

 

 

is meticulously fabricated and are hand-fi nished for

 

 

 

 

 

 

 

 

 

 

lasting beauty and enjoyment.

 

 

 

 

 

 

 

 

 

 

 

 

Our pledge to quality is completed as each model

 

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

 

 

undergoes a quality

control inspection.

From

 

 

 

 

AS BUILT-IN UNIT

 

 

 

 

 

 

 

 

 

A Top of Hopper

Top/Rear Vent

0 in.

(0mm)

design, to fabrication, to shipping:

We wish you

 

 

 

 

 

 

A

 

C

D

 

 

B Side of Outside Skin

Top/Rear Vent

0 in.

(0mm)

and your family many years of enjoyment in the

 

B

 

B

 

C Back of Hopper

Rear Vent

0 in.

(0mm)

C

 

 

 

 

 

 

 

 

 

 

 

Top Vent

2.5 in. (64mm)

warmth and comfort of your hearth appliance.

 

 

 

 

 

 

 

 

 

 

 

 

 

D Vent Pipe to Combustible

Rear Vent

3.0 in. (76mm)

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 in. Clearance To Exposed Section and Face Trim

 

E From Panel Edge

 

0 in.

(0mm)

Thank you for choosing Quadra-Fire.

 

 

 

 

 

 

 

 

 

 

 

 

Masonry or Zero Clearance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MANTEL

 

 

A Insert side to combustible

0 in.

 

0mm

 

 

 

 

 

 

Face Trim

 

 

 

 

 

 

 

 

 

 

 

 

 

B Insert top to mantel

12 in.

 

305mm

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Consult

WALL

C

C Insert top to face trim

0 in.

0mm

D Insert side face trim

0 in.

0mm

insurance carrier, local

SIDE

 

 

 

 

A

D

E Hearth extension from door opening

6 in.

152mm

 

 

building inspector, fi re

 

 

F Hearth extension from side of door opening

6 in.

152mm

F

E

DO NOT REMOVE THIS LABEL

 

7014-143

 

 

offi cials or authorities

 

 

 

 

 

having jurisdiction over

 

 

 

 

 

restrictions, installation

SAMPLE OF SERIAL NUMBER & DATE OF MANUFACTURE LABEL

inspection and permits.

LOCATION: Inside hopper on the top

 

 

 

 

 

HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN

CAUTION: BURNS. SEE NAMEPLATE AND INSTRUCTIONS. Operate this unit with fuel hopper lid closed. Failure to do so may result in emissions products’ combustion from the hopper under certain conditions. Maintain hopper seal in good condition. Do not overfill hopper.

ATTENTION: CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS. Opérez cet appareil avec le couvercle de la trémie fermé. Le défaut de ne pas suivre les instructions peut résulter, sous certaines conditions, en une combustion des émissions des produits venant de la trémie. Ne pas remplir la trémie trop pleine.

Tested and

O-T L

Portland Report / Rapport

 

CASTILE PELLET INSERT

 

SERIAL NO. / NUMÉRO DU SÉRIE

Listed by

US

Oregon USA

#061-S-42-2

 

 

 

 

 

C

 

 

 

 

 

007

OMNI-Test Laboratories, Inc.

 

 

 

U.S. ENVIRONMENTAL

 

 

 

DO NOT REMOVE THIS LABEL

Made in U.S.A.

PROTECTION AGENCY

 

2009

2010

2011

NE PAS ENLEVER L'ÉTIQUETTE

Fait Aux États-Unis

This model is exempt from EPA certification

 

 

 

 

 

 

 

 

 

 

 

under 40 CFR 60.531 by definition [Wood

 

 

 

 

 

 

 

Heater (A) "Air-to-Fuel Ratio"].

 

 

 

 

 

 

 

 

 

 

 

JAN FEB MAR APR MAY JUNE JULY AUG SEPT OCT NOV DEC

250-7262F

Test Lab &

Mfg Date

Model

Serial No.

Rpt Nbr.

 

Name

 

Page 2

250-7251G

August 20, 2009

Image 2
Contents 810-02901 MBK 810-03201 PMH Hot glass will cause burnsBuilding inspector, fi re Castile Pellet InsertInsurance carrier, local Inspection and permitsTable of Contents Mobile Home Approved Listing and Code ApprovalsAppliance Certification BTU & Efficiency Specifi cations Glass Specifi cationsGetting Started Appliance LocationNegative Pressure Castile Pellet Insert Locating Your Appliance & ChimneyDraft Inspect Appliance & Components and Pre-Use Check List Castile Pellet Insert Fire SafetyTools And Supplies Needed Height Width Panel Size Inch 3Dimensions and ClearancesAppliance Dimensions Shown Optional Outside Air Castile Pellet Insert Clearance To Combustibles, UL and ULC0mm Clearance To Exposed Section And Face Trim Inches MillimetersMinimum Opening for Masonry and Zero Clearance Fireplaces Castile Pellet Insert Masonry and Zero Clearance FireplacesFloor Protection Location Inches MillimetersStarter hole Mark area of floor to cut Castile Pellet Insert Prefabricated Metal Chimney Altering the Factory-Built FireplaceVenting Termination Requirements 4Vent InformationChimney and Exhaust Connection Example of 3 Elbow-Rear Vent Termination Calculation Pipe Selection ChartCastile Pellet Insert Equivalent Feet of Pipe Venting Systems Full Reline With Outside Air HorizontalCastile Pellet Insert Full Reline With Outside Air Vertical Mobile Home Installation 6Mobile Home7Appliance Set-Up Top Vent InstallationRear Vent Installation Reversible Top or Rear Flue Adapter Leveling SystemAssembled View Description20.3 Base Plate Only InstallationCastile Pellet Insert Zero Clearance Trim Support Cont’d 21.3 Panel Set And Cast Trim SetPanel & Trim Set, Econo Four Piece Log Set Installation Castile Pellet Insert Thermostat Installation 8Operating Instructions Fuel Size, Material and StorageBefore Your First Fire Fire CharacteristicsCastile Pellet Insert General Operating Information Starting Your First FireCastile Pellet Insert Feed Rate Adjustment Iginition CyclesFrequently Asked Questions Issues SolutionsTroubleshooting SymptomSymptom Possible Cause Corrective Action Page Types of Fuel Quick Reference Maintenance Chart10Maintaining & Servicing Your Appliance Frequency Daily Weekly Monthly YearlyNished. See .2 on Remove Cast Sides for Cleaning & MaintenanceCleaning Firepot with Cleaning Rod & Firepot Scraper Ash Removal from FireboxCleaning Beneath Heat Exchanger Cleaning Ash PanCleaning Heat Exchanger Chambers & Drop Tube Cleaning the Exhaust PathCleaning Exhaust Blower Requires No Lubrication Cleaning the HopperCleaning Convection Blower Requires No Lubrication Door Latch Inspection Cleaning the GlassPreparing Firebox for Non-Burn Season Frequency Yearly High Ash Fuel Content MaintenanceDoor Gasket Inspection Igniter Replacement Baffl e & Brick Set Removal 37.1Re-installing Baffl e & Brick Set Cont’d Component Function Snap Disc #1 Convection Blower 110F Vacuum SwitchWiring Harness See .1 below Snap Disc #2 Fuel Delivery Interrupt 250FCastile Pellet Insert Component Locations Blowers & Feed MotorCastile Pellet Insert Exploded Drawing 250-7251G August 20Castile Pellet Insert Service Parts and Accessories Important this is Dated Information HOW to OrderDescription Comments Part Number StockedAt Depot TOUCHUP-CSB Description ACCESSORIESComments Part Number PEL-DAMP4Description Comments Part Number Stocked at Depot FastenersCastile Pellet Insert Service And Maintenance Log Date of Service Performed By Description of ServiceCastile Pellet Insert Service And Maintenance Log Cont’d Castile Pellet Insert Warranty Policy Castile Pellet Insert Contact Information

CASTINS-CSB, 810-03201, 810-02901, CASTINS-CWL specifications

The Quadra-Fire 810-02901 and 810-03201, commonly referred to by their model designations CASTINS-CSB and CASTINS-CWL, represent a significant advancement in wood burning technology. These stoves are designed for efficiency, ease of use, and aesthetic appeal, catering to the increasing demand for sustainable and effective home heating solutions.

One of the standout features of these models is their high-efficiency combustion system. The technology employed in the Quadra-Fire 810 series optimizes fuel usage, ensuring that wood burns more completely. This not only maximizes heat output but also minimizes emissions, making it a more environmentally-friendly heating option compared to traditional wood stoves. By utilizing advanced combustion technology, these stoves can achieve higher efficiency ratings, which is essential for reducing heating costs and maintaining a comfortable indoor climate.

Both models come with a substantial firebox capacity, allowing users to load a significant amount of wood. This design feature ensures longer burn times and less frequent reloading, providing convenience for homeowners. The large viewing window creates an inviting ambiance and allows for a clear view of the mesmerizing flames, making these stoves a focal point in any living space.

The CASTINS-CSB model is particularly notable for its robust construction, featuring high-quality cast iron that provides excellent heat retention. This material not only contributes to durability but also enhances the overall thermal performance of the stove. The CASTINS-CWL model also incorporates a striking design with clean lines and a modern aesthetic, making it suitable for both traditional and contemporary home décor.

In terms of safety features, both models are equipped with advanced air control systems that facilitate easy adjustment of combustion airflow. This ensures safe operation and allows users to maintain optimal temperatures. The stoves are also designed to integrate with existing ventilation systems, promoting efficient airflow throughout the home.

Overall, the Quadra-Fire 810-02901 (CASTINS-CSB) and 810-03201 (CASTINS-CWL) models embody state-of-the-art wood burning technology with an emphasis on efficiency, quality, and design. These stoves are an ideal choice for homeowners looking to embrace a sustainable heating method without compromising on style or substance.