Quadra-Fire CASTINS-CSB, 810-03201 Panel Set And Cast Trim Set, Panel & Trim Set, Econo, 21.3

Page 21

R

Castile Pellet Insert

E. Panel Set And Cast Trim Set

Included in Panel Kit: (2) side panels, left and right; (1) panel top; (1) fastener package.

Included in Cast Trim Kit: (2) cast trim legs, left and right; (1) cast trim header; (2) cast trim footers, left and right; (1) fastener package.

Tools Needed: Powered Phillips head screw driver

1.Remove contents from box being careful not to scratch or damage the cast trim pieces.

2.Lay the panel set face down on protective covering to prevent scratching the painted surface.

3.Secure the panels legs to top panel with the screws provided.

4.Now bend the tabs down toward the backside of the panel set,

5on top and 2 on each leg. Leave the panel set face down.

5.Place the corresponding cast trim pieces ( 2 cast trim legs and

1cast trim header) underneath the panel set, also face down.

6.Place washer provided over tab and secure the trim and panel together with screw. Continue for all tabs.

7.Secure cast footers with screws.

8.Remove both left and right cast sides from insert, See Figures 32.1, 32.2 and 32.3 on page 32.

9.Slide panel and trim over the top of the insert into place matching the mounting tabs on the panel with the slots on the insert.

CAUTION

Do NOT pick up assembled unit by corners.

It is too heavy and may damage the panels.

Pick up from center.

F. Panel & Trim Set, Econo

Included in Panel & Trim Kit: (2) corner brackets and set screws; (1) trim set, 3 piece; (2) side panels; (1) top panel;

(4) screws;

Tools Needed: Powered Phillips head screw driver

1.Secure the top panel to the panel sides with the screws provided. Figure 21.3.

2.Assemble the gold trim with the (2) corner brackets provided. Figure 21.4.

3.Slide the assembled trim over the assembled panel set.

4.Slide panel and trim over the top of the insert into place matching the mounting tabs on the panel with the slots on the insert.

Back of Top Panel

 

Screws

 

Back of Side Panel

Figure

21.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Screw panels

 

 

 

 

2. Bend tabs down

 

 

together

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Screw panels

together

2. Bend tabs down

3. Install Cast Trim Header

Mounting tabs on each panel leg to match up with slots on insert.

View of "L" Bracket

installed

Figure 21.4

Figure 21.1

Figure 21.2 - Completed View

of Panel Set & Cast Trim Set

August 20, 2009

250-7251G

Page 21

Image 21
Contents Hot glass will cause burns 810-02901 MBK 810-03201 PMHInsurance carrier, local Castile Pellet InsertBuilding inspector, fi re Inspection and permitsTable of Contents Appliance Certification BTU & Efficiency Specifi cations Listing and Code ApprovalsMobile Home Approved Glass Specifi cationsAppliance Location Getting StartedCastile Pellet Insert Locating Your Appliance & Chimney DraftNegative Pressure Castile Pellet Insert Fire Safety Tools And Supplies NeededInspect Appliance & Components and Pre-Use Check List 3Dimensions and Clearances Appliance DimensionsHeight Width Panel Size Inch 0mm Clearance To Exposed Section And Face Trim Castile Pellet Insert Clearance To Combustibles, UL and ULCShown Optional Outside Air Inches MillimetersFloor Protection Castile Pellet Insert Masonry and Zero Clearance FireplacesMinimum Opening for Masonry and Zero Clearance Fireplaces Location Inches MillimetersStarter hole Mark area of floor to cut Altering the Factory-Built Fireplace Castile Pellet Insert Prefabricated Metal Chimney4Vent Information Chimney and Exhaust ConnectionVenting Termination Requirements Pipe Selection Chart Castile Pellet Insert Equivalent Feet of PipeExample of 3 Elbow-Rear Vent Termination Calculation Full Reline With Outside Air Horizontal Venting SystemsCastile Pellet Insert Full Reline With Outside Air Vertical 6Mobile Home Mobile Home InstallationRear Vent Installation Top Vent Installation7Appliance Set-Up Reversible Top or Rear Flue Adapter Leveling SystemDescription Assembled ViewBase Plate Only Installation Castile Pellet Insert Zero Clearance Trim Support Cont’d20.3 Panel Set And Cast Trim Set Panel & Trim Set, Econo21.3 Four Piece Log Set Installation Castile Pellet Insert Thermostat Installation Fuel Size, Material and Storage 8Operating InstructionsCastile Pellet Insert General Operating Information Fire CharacteristicsBefore Your First Fire Starting Your First FireIginition Cycles Castile Pellet Insert Feed Rate AdjustmentIssues Solutions Frequently Asked QuestionsSymptom TroubleshootingSymptom Possible Cause Corrective Action Page 10Maintaining & Servicing Your Appliance Quick Reference Maintenance ChartTypes of Fuel Frequency Daily Weekly Monthly YearlyCleaning Firepot with Cleaning Rod & Firepot Scraper Remove Cast Sides for Cleaning & MaintenanceNished. See .2 on Ash Removal from FireboxCleaning Heat Exchanger Chambers & Drop Tube Cleaning Ash PanCleaning Beneath Heat Exchanger Cleaning the Exhaust PathCleaning Convection Blower Requires No Lubrication Cleaning the HopperCleaning Exhaust Blower Requires No Lubrication Door Latch Inspection Cleaning the GlassHigh Ash Fuel Content Maintenance Door Gasket InspectionPreparing Firebox for Non-Burn Season Frequency Yearly Igniter Replacement 37.1 Baffl e & Brick Set RemovalRe-installing Baffl e & Brick Set Cont’d Component Function Wiring Harness See .1 below Vacuum SwitchSnap Disc #1 Convection Blower 110F Snap Disc #2 Fuel Delivery Interrupt 250FBlowers & Feed Motor Castile Pellet Insert Component Locations250-7251G August 20 Castile Pellet Insert Exploded DrawingImportant this is Dated Information HOW to Order Castile Pellet Insert Service Parts and AccessoriesStocked At DepotDescription Comments Part Number TOUCHUP-CSB PEL-DAMP4 Description ACCESSORIESComments Part NumberFasteners Description Comments Part Number Stocked at DepotDate of Service Performed By Description of Service Castile Pellet Insert Service And Maintenance LogCastile Pellet Insert Service And Maintenance Log Cont’d Castile Pellet Insert Warranty Policy Castile Pellet Insert Contact Information

CASTINS-CSB, 810-03201, 810-02901, CASTINS-CWL specifications

The Quadra-Fire 810-02901 and 810-03201, commonly referred to by their model designations CASTINS-CSB and CASTINS-CWL, represent a significant advancement in wood burning technology. These stoves are designed for efficiency, ease of use, and aesthetic appeal, catering to the increasing demand for sustainable and effective home heating solutions.

One of the standout features of these models is their high-efficiency combustion system. The technology employed in the Quadra-Fire 810 series optimizes fuel usage, ensuring that wood burns more completely. This not only maximizes heat output but also minimizes emissions, making it a more environmentally-friendly heating option compared to traditional wood stoves. By utilizing advanced combustion technology, these stoves can achieve higher efficiency ratings, which is essential for reducing heating costs and maintaining a comfortable indoor climate.

Both models come with a substantial firebox capacity, allowing users to load a significant amount of wood. This design feature ensures longer burn times and less frequent reloading, providing convenience for homeowners. The large viewing window creates an inviting ambiance and allows for a clear view of the mesmerizing flames, making these stoves a focal point in any living space.

The CASTINS-CSB model is particularly notable for its robust construction, featuring high-quality cast iron that provides excellent heat retention. This material not only contributes to durability but also enhances the overall thermal performance of the stove. The CASTINS-CWL model also incorporates a striking design with clean lines and a modern aesthetic, making it suitable for both traditional and contemporary home décor.

In terms of safety features, both models are equipped with advanced air control systems that facilitate easy adjustment of combustion airflow. This ensures safe operation and allows users to maintain optimal temperatures. The stoves are also designed to integrate with existing ventilation systems, promoting efficient airflow throughout the home.

Overall, the Quadra-Fire 810-02901 (CASTINS-CSB) and 810-03201 (CASTINS-CWL) models embody state-of-the-art wood burning technology with an emphasis on efficiency, quality, and design. These stoves are an ideal choice for homeowners looking to embrace a sustainable heating method without compromising on style or substance.