Quadra-Fire CASTINS-CSB Castile Pellet Insert General Operating Information, Fire Characteristics

Page 25

R

Castile Pellet Insert

B. General Operating Information

1. Thermostat Calls For Heat

The appliance is like most modern furnaces; when the thermostat calls for heat, your appliance will automatically light and deliver heat. When the room is up to temperature and the thermostat is satisfi ed, the red call light will shut off and the appliance will shut down. The red call light is located behind the left access panel.

C. Before Your First Fire

1.First, make sure your appliance has been properly installed and that all safety requirements have been met. Pay particular attention to the fi re protection, venting and thermostat installation instructions.

2.Double check that the ash pan and fi rebox are empty!

3.Check the position of the thermocouple, located above the fi repot, and make sure that it protrudes approximately 3/4 inch (19mm) into the fi repot.

2. Heat Output Controls

This appliance is equipped with a heat output control switch that has three settings or burn rates; low, medium and high. The appliance will turn on and off as the thermostat demands. When the thermostat calls for heat, the appliance will always start up on High. After burning approximately 4 minutes, the appliance will then burn at the rate at which it was originally set. If the appliance is set at one of the lower settings, it will run quieter but takes longer to heat up an area than if it were set at a higher burn rate. Regardless of the burn rate, when the area is warm enough to satisfy the thermostat, the appliance will shut off.

Heat Output

Switch

Right

Side

Ash Pan

Reset Button

Figure 25.1

WARNING

Fire Hazard.

Keep combustible materials, gasoline and other fl ammable vapors and liquids clear of appliance.

Do NOT store fl ammable materials in the appliance’s vicinity.

DO NOT USE GASOLINE, LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR “FRESHEN UP” A FIRE IN THIS HEATER.

DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL.

DO NOT USE CHEMICALS OF FLUIDS TO START THE FIRE.

Keep all such liquids well away from the heater while it is in use.

Combustible materials may ignite.

4. Close the front door.

CAUTION

Tip of thermocouple must be in contact with the inside end of the thermocouple cover.

Missed ignitions can occur.

D. Starting Your First Fire

1.A thermostat is required for proper operation of this appliance, except for corn. At this time, fi ll the hopper with pellets, set the thermostat to its lowest setting. Plug the power cord into nearby outlet.

2.The exhaust blower will stay on for approximately 18 minutes even though the thermostat is not calling for heat. This is normal.

3.Locate the heat output control switch behind the right face on the lower right side of the fi rebox. Set to the HIGH setting and then adjust the thermostat to its highest setting. The red call light will be on which is located on the top of the junction box behind the right cast side. This indicates the thermostat is calling for heat. Figure 25.1.

4.The fuel feed system and the igniter should now be on.

5.For your fi rst fi re it will be necessary to press the reset button once a minute until pellets start to drop into the fi repot, then press button 1 more time. This will fi ll the feed system and allow the appliance to begin dropping pellets. The appliance will continue to run as long as the thermostat is calling for heat.

6.Once the appliance has ignited, let it burn for approximately 15 minutes, then set the thermostat to the desired room temperature. Adjust the heat output control switch to the desired setting.

E. Fire Characteristics

A properly adjusted fi re with the heat output control switch set on “HIGH” has a short active fl ame pattern that extends out of the fi repot approximately 4 inches (102mm). If the fi re has tall fl ames with black tails and seems somewhat lazy, the feed rate will need to be reduced. If the fi re is not 4 inches (102mm) tall, increase the feed rate. A medium and low setting will give a shorter fl ame. The fl ame will rise and fall somewhat. This is normal.

August 20, 2009

250-7251G

Page 25

Image 25
Contents Hot glass will cause burns 810-02901 MBK 810-03201 PMHInsurance carrier, local Castile Pellet InsertBuilding inspector, fi re Inspection and permitsTable of Contents Appliance Certification BTU & Efficiency Specifi cations Listing and Code ApprovalsMobile Home Approved Glass Specifi cationsAppliance Location Getting StartedDraft Castile Pellet Insert Locating Your Appliance & ChimneyNegative Pressure Tools And Supplies Needed Castile Pellet Insert Fire SafetyInspect Appliance & Components and Pre-Use Check List Appliance Dimensions 3Dimensions and ClearancesHeight Width Panel Size Inch 0mm Clearance To Exposed Section And Face Trim Castile Pellet Insert Clearance To Combustibles, UL and ULCShown Optional Outside Air Inches MillimetersFloor Protection Castile Pellet Insert Masonry and Zero Clearance FireplacesMinimum Opening for Masonry and Zero Clearance Fireplaces Location Inches MillimetersStarter hole Mark area of floor to cut Altering the Factory-Built Fireplace Castile Pellet Insert Prefabricated Metal ChimneyChimney and Exhaust Connection 4Vent InformationVenting Termination Requirements Castile Pellet Insert Equivalent Feet of Pipe Pipe Selection ChartExample of 3 Elbow-Rear Vent Termination Calculation Full Reline With Outside Air Horizontal Venting SystemsCastile Pellet Insert Full Reline With Outside Air Vertical 6Mobile Home Mobile Home InstallationRear Vent Installation Top Vent Installation7Appliance Set-Up Reversible Top or Rear Flue Adapter Leveling SystemDescription Assembled ViewCastile Pellet Insert Zero Clearance Trim Support Cont’d Base Plate Only Installation20.3 Panel & Trim Set, Econo Panel Set And Cast Trim Set21.3 Four Piece Log Set Installation Castile Pellet Insert Thermostat Installation Fuel Size, Material and Storage 8Operating InstructionsCastile Pellet Insert General Operating Information Fire CharacteristicsBefore Your First Fire Starting Your First FireIginition Cycles Castile Pellet Insert Feed Rate AdjustmentIssues Solutions Frequently Asked QuestionsSymptom TroubleshootingSymptom Possible Cause Corrective Action Page 10Maintaining & Servicing Your Appliance Quick Reference Maintenance ChartTypes of Fuel Frequency Daily Weekly Monthly YearlyCleaning Firepot with Cleaning Rod & Firepot Scraper Remove Cast Sides for Cleaning & MaintenanceNished. See .2 on Ash Removal from FireboxCleaning Heat Exchanger Chambers & Drop Tube Cleaning Ash PanCleaning Beneath Heat Exchanger Cleaning the Exhaust PathCleaning Convection Blower Requires No Lubrication Cleaning the HopperCleaning Exhaust Blower Requires No Lubrication Door Latch Inspection Cleaning the GlassDoor Gasket Inspection High Ash Fuel Content MaintenancePreparing Firebox for Non-Burn Season Frequency Yearly Igniter Replacement 37.1 Baffl e & Brick Set RemovalRe-installing Baffl e & Brick Set Cont’d Component Function Wiring Harness See .1 below Vacuum SwitchSnap Disc #1 Convection Blower 110F Snap Disc #2 Fuel Delivery Interrupt 250FBlowers & Feed Motor Castile Pellet Insert Component Locations250-7251G August 20 Castile Pellet Insert Exploded DrawingImportant this is Dated Information HOW to Order Castile Pellet Insert Service Parts and AccessoriesAt Depot StockedDescription Comments Part Number TOUCHUP-CSB PEL-DAMP4 Description ACCESSORIESComments Part NumberFasteners Description Comments Part Number Stocked at DepotDate of Service Performed By Description of Service Castile Pellet Insert Service And Maintenance LogCastile Pellet Insert Service And Maintenance Log Cont’d Castile Pellet Insert Warranty Policy Castile Pellet Insert Contact Information

CASTINS-CSB, 810-03201, 810-02901, CASTINS-CWL specifications

The Quadra-Fire 810-02901 and 810-03201, commonly referred to by their model designations CASTINS-CSB and CASTINS-CWL, represent a significant advancement in wood burning technology. These stoves are designed for efficiency, ease of use, and aesthetic appeal, catering to the increasing demand for sustainable and effective home heating solutions.

One of the standout features of these models is their high-efficiency combustion system. The technology employed in the Quadra-Fire 810 series optimizes fuel usage, ensuring that wood burns more completely. This not only maximizes heat output but also minimizes emissions, making it a more environmentally-friendly heating option compared to traditional wood stoves. By utilizing advanced combustion technology, these stoves can achieve higher efficiency ratings, which is essential for reducing heating costs and maintaining a comfortable indoor climate.

Both models come with a substantial firebox capacity, allowing users to load a significant amount of wood. This design feature ensures longer burn times and less frequent reloading, providing convenience for homeowners. The large viewing window creates an inviting ambiance and allows for a clear view of the mesmerizing flames, making these stoves a focal point in any living space.

The CASTINS-CSB model is particularly notable for its robust construction, featuring high-quality cast iron that provides excellent heat retention. This material not only contributes to durability but also enhances the overall thermal performance of the stove. The CASTINS-CWL model also incorporates a striking design with clean lines and a modern aesthetic, making it suitable for both traditional and contemporary home décor.

In terms of safety features, both models are equipped with advanced air control systems that facilitate easy adjustment of combustion airflow. This ensures safe operation and allows users to maintain optimal temperatures. The stoves are also designed to integrate with existing ventilation systems, promoting efficient airflow throughout the home.

Overall, the Quadra-Fire 810-02901 (CASTINS-CSB) and 810-03201 (CASTINS-CWL) models embody state-of-the-art wood burning technology with an emphasis on efficiency, quality, and design. These stoves are an ideal choice for homeowners looking to embrace a sustainable heating method without compromising on style or substance.